Yoo Seong Yeon;Chung Min Ho;Kim Ki Hyung;Lee Je Myo
Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.17
no.2
/
pp.117-124
/
2005
Aluminum plate heat exchanger, rotary wheel heat exchanger, and heat pipe heat exchanger have been used (or ventilation heat recovery in the air-conditioning system. The purpose of this research is to develop high efficiency plastic plate heat exchanger which can substitute aluminum plate heat exchanger. Because thermal conductivity of plastic is quite small compared to that of aluminum, various heat transfer enhancement techniques are applied in the design of plastic plates. Five types of heat exchanger model are designed and manufactured, which are plate type, plate-fin type, turbulent promoter type, corrugate type, and dimple type. Thermal performance and pressure loss of each heat exchangers are measured in various operating conditions, and compared each other. Test results show that heat transfer performance of corrugate type, turbulent promoter type, and dimple type are increases about $43\%$, $14\%$, and $33\%$ at the equivalent fan power compared to those of plate type, respectively. On the other hand, the heat transfer performance of plate-fin type decreases $9\%$ because fins can not play their own role.
Kim, Hye-Rin;You, Dong Geun;You, Jae Hwan;Jang, Jun Won;Choi, Moo Kyu;Hong, Seung Chan;Ko, Jae-Hyeon;Joe, Sung-Yoon;Kim, Yongduk;Park, Taehee;Ko, Young Wook
Korean Journal of Optics and Photonics
/
v.32
no.5
/
pp.220-229
/
2021
The optical characteristics of high-power direct-lit white light-emitting diode (LED) lighting were investigated, where a quantum dot (QD) film was adopted to enhance the color-rendering index (CRI). The transmittance of the diffuser plate and the concentration of the QD film were varied in this study. The color coordinates and the correlated color temperature (CCT) did not show any appreciable change, while the CRI values increased slightly as the transmittance of the diffuser plate decreased. The investigated optical properties were nearly independent of the viewing angle, and the luminance distribution was close to Lambertian. The CCT decreased from approximately 6000 K to approximately 4000 K as the concentration of the QD film increased from 0 to 7.5 wt%, which was due to the enhanced red component in the emission spectrum. The CRI increased to approximately 95 for some optical configurations of the lighting. These results demonstrate that glare-free, color-changeable, high-rendering LED lighting can be realized by using a combination of a diffuser plate of appropriate transmittance and a red QD film.
The characteristics of high heat input (342kJ/cm) EG (Electro Gas Arc) welded joint of EH36-TM steel has been investigated. The weld metal microstructure consisted of fine acicular ferrite (AF), a little volume of polygonal ferrite (PF) and grain boundary ferrite (GBF). Charpy impact test results of the weld metal and heat affected zone (HAZ) met the requirement of classification rule (Min. 34J at $-20^{\circ}C$). In order to evaluate the relationship between the impact toughness property and the grain size of HAZ, the austenite grain size of HAZ was measured. The prior austenite grain size in Fusion line (F.L+0.1 mm) was about $350{\mu}m$. The grain size in F.L+1.5 mm was measured to be less than $30{\mu}m$ and this region was identified as being included in FGHAZ(Fine Grain HAZ). It is seen that as the austenite grain size decreases, the size of GBF, FSP (Ferrite Side Plate) become smaller and the impact toughness of HAZ increases. Therefore, the CGHAZ was considered to be area up to 1.3mm away from the fusion line. Results of TEM replica analysis for a welded joint implied that very small size ($0.8\sim1.2{\mu}m$) oxygen inclusions played a role of forming fine acicular ferrite in the weld metal. A large amount of (Ti, Mn, Al)xOy oxygen inclusions dispersed, and oxides density was measured to be 4,600-5,300 (ea/mm2). During the welding thermal cycle, the area near a fusion line was reheated to temperature exceeding $1400^{\circ}C$. However, the nitrides and carbides were not completely dissolved near the fusion line because of rapid heating and cooling rate. Instead, they might grow during the cooling process. TiC precipitates of about 50 ~ 100nm size dispersed near the fusion line.
Jo, Eunsun;Choi, Jin Woong;Kim, Min Sook;Kim, Heecheul;Lee, Young Hak
Journal of the Computational Structural Engineering Institute of Korea
/
v.28
no.3
/
pp.267-274
/
2015
In this paper, an experimental evaluation of shear strength of wide beam is presented. By the experiment in paper, shear strength depending on parameter of shear reinforcement by GFRP plate on wide beam is investigated. Specimens are 7 of reinforced by GFRP plate with openings. The shear reinforcement is manufactured into plate shape with openings to ensure perfect integration with concrete. The test was performed on 7 specimens. The parameters are including number of shear reinforcement by GFRP plates and center-to-center spacing between vertical strip. We analysed the crack, failure mode, strain, shear strength of specimens. A calculation of the shear strength of reinforced wide beam with GFRP plate based on ACI 318-11. The result of the experiment shows that the GFRP plate is works successfully as shear reinforcement in the wide beam.
Hwang, Sung Tack;Cheon, Seung Ho;Song, Jun Seok;Yun, Young-Hoon;Kim, Byeong Heon;Zhang, Xia;Kim, Dae-Ung;Hyun, Deoksu;Oh, Byeong Soo
Transactions of the Korean Society of Automotive Engineers
/
v.22
no.4
/
pp.65-71
/
2014
As an important component of a fuel cell, the bipolar plate comprises a large proportion in the fuel cell's volume, weight and price. The bipolar plate is the most widely used; however, graphite bipolar plate is large in volume, brittle and therefore easily broken during assembling. In addition, due to its poor machinability, production costs a lot, unless mass production. Compared with the graphite bipolar plate, the metal bipolar plate has good machinability, high electric conductivity and strong mechanical strength; however, it corrodes easily and has a high contact resistance, so in order to prevent corrosion and reduce the contact resistance, the basic metal needs to be processed by use of electro polishing and coating. The water which is produced by electrochemical reactions in the fuel cell must be discharged smoothly. In this study, in order to prevent corrosion the processes of electro polishing and CrN coating were used. According to the presence or absence of these processes, the contact angles can be measured and different metal bipolar plates can be made, these plates can be used for comparing and analyzing the performance of the fuel cell.
Transactions of the Korean Society of Automotive Engineers
/
v.14
no.4
/
pp.12-19
/
2006
It is positively necessary to study on the stiffness of a 13degree-type impact tester in order to improve the fracture prediction of impact testing in wheels using FE(finite-element) analysis. The 13degree-type impact tester consists of an impact striker, a wheel fixer, a steel plate, and four cylindrical rubbers. Important parts of the tester are the steel plate and four cylindrical rubbers which play a role of absorbing impact energy during impact testing. Because of these buffers, the RF(reaction force) variation of the lower part in the 13degree-type impact tester showed the tendency like a damped harmony oscillation during impact testing. In order to investigate the stiffness of a 13degree-type impact tester, this work measured each stiffness of a steel plate and cylindrical rubbers. The stiffness of a cylindrical rubber was measured using a compressive tester. On the other hand, the stiffness of a steel plate was predicted by simulating experimental method using FE analysis.
Vacuum chambers have wide application for a variety of purposes such as material processing, vacuum gauge calibration, etc. As the dynamic pressure generated in such chamber is non-uniform, in many industrial as well as research processes, it is vital to know the non-uniform gas distribution with associated gas flow regimes and the ways of minimizing these pressure non-uniformities. In the present work, the behavior of gas flow in a vacuum chamber, during continuous gas flow, is described in the pressure range 0.1-133 Pa and the effect of baffle plate in minimizing the pressure non-uniformities is investigated. It was observed that maximum deviations in the pressure occur near the gas inlet point and that the effect of baffle plate in minimizing the pressure non-uniformities is more obvious in the transitional flow regime.
Purpose: The purpose of this study is to identify the changes of a physiologic nature and the sedative parameters associated with dexmedetomidine and pethidine, in patients undergoing plate and screw removal surgery, after orthognathic surgery. Methods: Twenty-three patients were sedated with dexmedetomidine and pethidine during plate and screw removal, after orthognathic surgery. An initial loading dose of dexmedetomidine ($1.0{\mu}g/kg$ infused over 10 minutes) was followed by a maintenance dose ($1.0{\mu}g/kg/hr$). Systolic blood pressure, diastolic blood pressure, mean arterial pressure, oxygen saturation, and heart rate were monitored. Perioperative amnesia and anxiety were recorded. Results: Significant changes were found in the blood pressure and heart rate (Freidman test, P<0.05), but not in oxygen saturation (Freidman test, P>0.05). Amnesia during local injection was observed in eight patients (34.8%). Compared with the preoperative anxiety score, the intraoperative anxiety score was decreased. Conclusion: In this study, we found cardiovascular and respiratory stability in intravenous sedation using dexmedetomidine with pethidine, in plate and screw removal, after orthognathic surgery. Furthemore, intravenous sedation using dexmedetomidine with pethidine shows adequate analgesic and sedative effects.
Purpose: To present clinical results of proximal first metatarsal opening wedge osteotomy and low profile plate fixation in hallux valgus deformity. Materials and Methods: Thirty-two patients (39 feet) underwent surgery for hallux valgus deformity. Fourteen patients (18 feet; Group A) underwent proximal first metatarsal opening wedge osteotomy fixed with low profile titanium plate ($Arthrex^{(R)}$), and 18 patients (21 feet; Group B) underwent proximal chevron osteotomy with two K-wires. Improvement in hallux valgus angle (HVA), 1, 2 intermetatarsal angle (IMA), range of motion of 1st metatarsophalangeal joint, VAS score, and the length of first metatarsal on weight-bearing radiograph were evaluated preoperatively and at final follow-up. Results: HVA improved from $36.2{\pm}6.6$ degrees to $11.7{\pm}5.1$ degrees, and 1, 2 IMA improved from $15.7{\pm}2.6$ degrees to $7.2{\pm}1.9$ degrees. VAS score improved from $7.2{\pm}1.2$ to $1.4{\pm}0.9$. There were no significant differences clinically and radiologically. Conclusion: Proximal first metatarsal opening wedge osteotomy with stable fixation using low profile plate may be an effective surgical option for correction of hallux valgus deformity.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.