• 제목/요약/키워드: Center of rotation error

검색결과 65건 처리시간 0.03초

Correlation analysis between rotation parameters and attitude parameters in simulated satellite image

  • Yun, Young-Bo;Park, Jeong-Ho;Yoon, Geun-Won;Park, Jong-Hyun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.553-558
    • /
    • 2002
  • Physical sensor model in pushbroom satellite images can be made from sensor modeling by rotation parameters and attitude parameters on the satellite track. These parameters are determined by the information obtained from GPS, INS, or star tracker. Provided from satellite image, an auxiliary data error is connected directly with an error of rotation parameters and attitude parameters. This paper analyzed how obtaining satellite images influenced errors of rotation parameters and attitude parameters. furthermore, for detailed analysis, this paper generated simulated satellite image, which was changed variously by rotation parameters and attitude parameters of satellite sensor model. Simulated satellite image is generated by using high-resolution digital aerial image and DEM (Digital Elevation Model) data. Moreover, this paper determined correlation of rotation parameter and attitude parameters through error analysis of simulated satellite image that was generated by various rotation parameters and attitude parameters.

  • PDF

표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가 (Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target)

  • 최영세;박효국;김세영;김주호;이상규;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.53-64
    • /
    • 2017
  • 목 적: 표적의 길이가 긴(length) 환자의 용적회전변조 방사선치료(V-MAT) 시 회전방향 오차의 크기에 따른 선량차이 경향을 $HexaPOD^{TM}$ evo RT system(6DoF couch)을 통해 알아보고 그 유용성을 평가하고자 하며, 이에 따른 회전오차 보정의 필요성을 제안하고자 한다. 대상 및 방법: 본원에서 치료를 받은 Esophagus cancer와 SCL을 포함한 Breast cancer 환자 중 HexaPOD 6DoF(Six-Degree of Freedom) couch를 사용한 10명을 대상으로 하였다. 6DoF couch를 이용하여 Rx(pitch), Ry(roll), Rz(yaw) 방향의 회전오차의 적용여부에 따른 선량차이를 알아보기 위하여 x, y, z축에 대한 자세오차를 확인하고, 자세 회전오차 값을 6DoF couch에 부여 임의의 오차를 발생시켜 변형된 선량계측 품질보증(Delivery Quality Assurance, DQA)을 시행, 점 선량과 감마값을 비교 분석하였다. 추가적으로 3cm의 직경에 5, 10, 15, 20 cm의 길이를 가진 각각의 표적의 치료계획에 회전오차의 크기를 $1^{\circ}$ 간격으로 적용한 후, 표적의 길이와 회전오차의 종류 및 크기에 따른 감마통과율의 변화양상을 확인했다. 결 과: 자세 회전오차가 적용된 경우의 점 선량과 감마통과율의 평균오차는 각각 Rx 방향에서 $2.50{\pm}1.11%$, $84.1{\pm}7.39%$, Ry 방향에서 $2.36{\pm}1.16%$, $81.0{\pm}8.49%$, Rz 방향에서 $2.35{\pm}1.10%$, $84.4{\pm}6.99%$를 나타냈다. 또한, 표적의 길이와 회전오차의 종류 및 크기에 따른 감마통과율 분석 결과 Ry 방향을 제외한 Rx와 Rz 방향에서 회전오차가 커질수록 감마통과율은 전반적으로 감소하는 경향을 보였으며, 특히 10 cm의 표적, Rz 방향으로 $2.5^{\circ}$ 회전오차가 부여된 경우에서 가장 낮은 감마통과율인 74.2 %를 나타냈다. 결 론: 표적의 길이가 긴 치료부위의 용적회전변조 방사선치료 시 회전오차의 보정은 필요하며, 6DoF couch의 사용은 환자자세의 재현성과 치료의 질적 효율을 높일 것으로 사료된다.

  • PDF

토모치료기 CatcherTM Couch의 유용성에 대한 고찰 (Study of the CatcherTM Couch's Usefulness)

  • 엄기천;이충환;전수동;송흥권;백금문
    • 대한방사선치료학회지
    • /
    • 제31권2호
    • /
    • pp.65-74
    • /
    • 2019
  • 목 적: 최근 Radixact® X9에서는 치료테이블의 처짐을 방지하는 CatcherTM가 추가되었다. 본 연구에서는 정확한 선량전달을 위한 토모테라피의 메가볼트 전산화단층촬영(MVCT) 영상유도방사선치료 시 Tomo-HDA®의 General Couch와 Radixact® X9의 CatcerTM Couch의 치료테이블 처짐 정도를 팬텀을 이용하여 정량적으로 비교하고 그 유용성을 평가하고자 한다. 대상 및 방법: 팬텀연구를 위해 란도팬텀을 이용하였으며, 치료부위에 따른 변화를 위해 두경부와 골반부에 중심점을 설정하였다. 또한, 무게에 따른 변화를 위해 자체 제작한 저용융점납합금을 이용하였다. 납합금의 무게를 점차 증가시켜(A: 15kg, A+B: 30kg, A+B+C: 45kg) MVCT 영상을 획득하였으며, 수직오차 및 회전(Pitch)오차를 측정하였다. 환자연구를 위해 본원에서 토모테라피를 이용하여 방사선치료를 받은 120명의 환자를 선정하였다. Tomo-HDA®과 Radixact® X9에서 각각 60명씩 치료를 받았으며, 치료부위는 두경부와 골반부로 30명씩 분류하여 선정하였다. 환자연구 방법으로는 치료 첫 날 획득한 MVCT 영상의 척추를 기준으로 수직오차 및 회전(Pitch) 오차를 측정하여 평균값을 산출하였다. 결 과: 팬텀연구 결과 Tomo-HDA®의 General Couch에서는 무게가 증가함에 따라 두경부와 골반부 모두 수직 및 회전(Pitch)오차가 비례하여 증가하였고, 두경부에서 최대 7.52mm, 0.38°, 골반부에서 최대 11.94mm, 0.92° 발생하였다. Radixact® X9의 CatcherTM Couch에서는 0.02~0.1mm, 0~0.04°의 오차범위가 발생하는 것을 확인할 수 있었다. 환자연구 결과 Radixact® X9의 CatcherTM Couch에서 두경부 4.79mm, 0.33°, 골반부 7.66mm, 0.22° 더 낮게 측정되었다. 결 론: 팬텀연구 결과 Tomo-HDA®의 General Couch에서는 무게가 증가함에 따라 수직오차 및 회전(Pitch) 오차가 비례하여 증가하였으며, 특히 두경부보다는 골반부에서 더 많이 증가하였다. 하지만, 본 연구의 목적인 Radixact® X9의 CatcherTM Couch에서는 무게와 부위라는 변수상관 없이 일정한 오차가 발생하였다. 결론적으로 CatcherTM Couch는 Couch 처짐이라는 Mechanical error를 최소화 할 수 있으며, 두경부보다는 골반부에서 더 유용하게 작용한다는 사실을 알 수 있었다. 토모테라피를 이용한 방사선치료 시 Radixact® X9의 CatcherTM Couch를 사용한다면 토모테라피의 특성상 보정할 수 없는 회전(Pitch)오차를 최소화하는데 기여할 수 있을 것이라고 사료된다.

Inference on the Joint Center of Rotation by Covariance Pattern Models

  • Kim, Jinuk
    • 한국운동역학회지
    • /
    • 제28권2호
    • /
    • pp.127-134
    • /
    • 2018
  • Objective: In a statistical linear model estimating the center of rotation of a human hip joint, which is the parameter related to the mean of response vectors, assumptions of homoscedasticity and independence of position vectors measured repeatedly over time in the model result in an inefficient parameter. We, therefore, should take into account the variance-covariance structure of longitudinal responses. The purpose of this study was to estimate the efficient center of rotation vector of the hip joint by using covariance pattern models. Method: The covariance pattern models are used to model various kinds of covariance matrices of error vectors to take into account longitudinal data. The data acquired from functional motions to estimate hip joint center were applied to the models. Results: The results showed that the data were better fitted using various covariance pattern models than the general linear model assuming homoscedasticity and independence. Conclusion: The estimated joint centers of the covariance pattern models showed slight differences from those of the general linear model. The estimated standard errors of the joint center for covariance pattern models showed a large difference with those of the general linear model.

고밀도 광저장 기기용 틸트 액추에이터 동특성 분석 및 평가 (Evaluation and Analysis of Dynamic Characteristics in Tilt Actuator for High Density Optical Storage Devices)

  • 김석중;이용훈;최한국
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.584-595
    • /
    • 2000
  • We design a new actuator for high density optical device in order to control the radial tilting motion. The newly designed actuator makes it possible to control the tilting motion actively, while the coventional actuator compress tilting motion with passive spring. First of all, We present 3-dimensional modeling of actuator and accomplish the modal analysis and magnetic analysis of actuator. Due to these results, a new designed actuator has performance of high sensitivity and high second resonance frequency. Secondly, We present the 3-DOF dynamic modeling of the 4-wire spring type actuator. sensitivity analysis is performed to consider the assembling error, such as the difference of mass center and force center. From these results, the sensitivities of rotation due to the assembly error are revealed and design criteria of rotation is presented. And experimental results of a newly designed actuator are presented and compared with theoretical results. Finally, We propose a dynamic tilt compensation and high acceleration actuator for high density optical storage devices.

  • PDF

정상인과 뇌졸중 환자의 체간 위치감각 비교 및 보행과 균형에 미치는 영향 (Comparison Between Stroke Patients and Normal Persons for Trunk Position Sense and It's Relation to Balance and Gait)

  • 양해덕;김창범;최종덕;문영
    • 한국전문물리치료학회지
    • /
    • 제27권3호
    • /
    • pp.178-184
    • /
    • 2020
  • Background: Stroke patients have reduced trunk control compared to normal people. The ability to control the trunk of a stroke patient is important for gait and balance. However, there is still a lack of research methods for the characteristics of stroke control in stroke patients. Objects: The aim of this research was to determine whether trunk position sense has any relation with balance and gait. Methods: This study assessed trunk performance by measuring position sense. Trunk position sense was assessed using the David back concept to determine trunk repositioning error in 20 stroke patients and 20 healthy subjects. Four trunk movements (flexion, extension, lateral flexion, rotation) were tested for repositioning error and the measurement was carried out 6 times per move; these parameters were used to compare the mean values obtained. Subjects with stroke were also evaluated with clinical measures of balance and gait. Results: There were significant differences in trunk repositioning error between the stroke group and the control group in flexion, lateral flexion to the affected side, lateral flexion to the unaffected side, rotation to the affected side, and rotation to the unaffected side. Mean flexion error: post-stroke: 7.95 ± 6.76 degrees, control: 3.32 ± 2.27; mean lateral flexion error to the affected side: 6.13 ± 3.79, to the unaffected side: 5.32 ± 3.15, control: 3.57 ± 1.92; mean rotation error to the affected side: 8.25 ± 3.09, to the unaffected side: 9.24 ± 3.94, control: 5.41 ± 1.82. There was an only significant negative correlation between the repositioning error of lateral flexion and the Berg balance scale score to the affected side (-0.483) and to the unaffected side (-0.497). A strong correlation between balance and gait was found. Conclusion: The results of this study indicate that stroke patients exhibit greater trunk repositioning error than age-matched controls on all planes of movement except for extension. And lateral flexion has correlation with balance and gait.

비구면 평행연삭에서의 휠구면형상 창성오차 (Wheel curve generation error of aspheric grinding in parallel grinding method)

  • 황연;;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.344-349
    • /
    • 2005
  • This paper presents a geometrical error analysis of wheel curve generation method for micro aspheric surface machining using parallel grinding method. In aspheric grinding, wheel wear in process is crucial parameter for profile error of the ground surface. To decrease wheel weal parallel grinding method is adopted. Wheel and work piece (Tungsten carbide) contact point changes during machining process. In truing process of the wheel radius is determined by the angle and distance between wheel and truer. Wheel radius error is predominantly affected by vertical deviation between the wheel rotation center and the truer center Simulation for vertical error and wheel radius error shows same tendency that expected by geometrical analysis. Experimental results show that the analysis of curve generation method matches with simulations and wheel radius errors.

  • PDF

양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법 (Automated patient set-up using intensity based image registration in proton therapy)

  • 장훈;김호식;최승오;김은숙;정종휘;안상희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.97-105
    • /
    • 2018
  • 목 적 : Proton Therapy는 Bragg-peak를 이용해 종양에는 최대의 선량, 정상조직에는 최소의 선량을 줄 수 있는 특징을 가지고 있기 때문에 환자의 위치변화나 치료부위의 위치 변화를 정량화 할 수 있는 의료영상 분석 시스템은 양성자 치료에 있어서 무엇보다도 중요하다. 본 연구 목적은 Matlab 기반의 In-house Registration code를 제작하여 기존 DIPS program을 통한 Set-up과 In-house code를 통한 영상정합을 비교하여 Algorithm의 유용성을 평가하고 DIPS와 DRR간의 오차 값을 확인하여 기존 치료의 정확성을 평가하고자 한다. 대상 및 방법 : 본원에서 양성자 치료를 받은 13명의 뇌종양, 두경부암 환자를 대상으로 하였으며 영상비교에 필요한 DIPS Program System(Version 2.4.3, IBA, Belgium)와 환자의 치료계획을 위해 Eclipse Proton Planning System(Version 13.7, Varian, USA)을 사용하였다. Registration 방법에 대한 Validation을 위해 Test image를 인위적으로 회전 및 이동하여 기존 Image와 영상정합 하였고, 기존 Set up 방식의 DIPS program의 환자 일별 초기 Set up image를 plan DRR과 영상정합 하여 각각 오차 값을 얻어 Algorithm의 유용성을 평가하였다. 그리고 기존 Set up 방식의 정확성을 평가하기 위해 환자 일별 최종 Set up image와 DRR image를 영상정합하여 오차 값을 확인하였다. 결 과 : Test image를 left와 right 방향으로 각각 0.5, 1, 10 cm를 이동시켰을 때 평균 0.018 cm의 오차 값을 보였으며 시계와 반시계방향으로 각각 1, $10^{\circ}$씩 회전시켰을 경우에는 평균 $0.0011^{\circ}$의 오차를 나타냈다. 4명의 환자 일별 초기 image를 영상정합 하였을 때는 x, y, z 방향 순으로 평균 0.056, 0.044, 0.053 cm의 오차 값을 나타냈으며 Rotation, Pitch 순으로 0.190, $0.206^{\circ}$의 차이를 나타냈다. 13명의 환자 일별 최종 image를 영상 정합 하였을 때는 x, y, z 방향 순으로 평균 차이는 0.062, 0.085, 0.074 cm이였고 Vector 값으로는 평균 0.120 cm의 차이를 보였다. Rotation, Pitch 순으로는 평균 0.171, $0.174^{\circ}$의 차이 값을 나타냈다. 결 론 : 본 연구를 통해 제작된 Matlab 기반의 In-house Registration code는 단순한 Image 뿐만 아니라 해부학적 구조에서도 Intensity 기반의 정확한 영상정합을 나타냈다. 또한 기존 치료방식의 DIPS program을 통한 Set-up 오차는 매우 미미한 차이를 보임으로써 이는 양성자치료의 정확성을 확인할 수 있었다. 앞으로 임상적용을 위해 추가적인 프로그램 개발과 향후 Intensity 기반의 Matlab In-house code 연구가 필요하다고 사료된다.

  • PDF

페룰 동축연삭시 척킹 오차 해석 (A study on the chucking alignment error analysis in coaxial grinding of ferrule)

  • 김동길;김영태;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.9-14
    • /
    • 2002
  • Ferrule is widely used as fiber optic connecters. In fiber-optic communications, the shape accuracy such as coaxiality and cylindricity of ferrule affects insertion loss. When coaxial grinding of ferrule supported by two pin, pin alignment and chucking accuracy are very important. In this research, the kinematic behavior of the ferrule center is investigated in the case where cone-shaped center pins and round circle hales which make contact with each other near the edge of the holes, using homeogenous coordinate transformation and numerical analysis. The obtained results are as follows: The alignment errors between center pins alone do not affect the rotation accuracy of ferrule. The alignment errors between center holes cause a sinusoidal displacement of ferrule. And the maximum displacement of ferrule centers increase in proportion to the center pin angle in the case of a fixed alignment errors

  • PDF

A Design of Free Velocity Bias for GPS Receiver

  • Nguyen, Phi-Long;Kim, Hyun-Soo;Kim, Han-Sil
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.537-542
    • /
    • 2007
  • This paper proposes a 2-step Kalman filter model for land vehicle navigation using civilian-band GPS measurements. The velocity bias caused by the Earth#s rotation would be removed completely when applying this model. Because the linearization of velocity equations in this model is not necessary, the error is significantly reduced. The experiment reveals that estimated position error with stationary data is about 5m during a 15-20 minute interval. The other benefit of this model is that it can be feasibly applied as a GPS receiver module thanks to the small sizes of the necessary manipulating matrices.