• Title/Summary/Keyword: Center Pixel

Search Result 422, Processing Time 0.054 seconds

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Development of Adaptive Spatial Filter to Improve Noise Characteristics of PET Images (PET 영상의 잡음개선을 위한 적응적 공간 필터 개발)

  • Woo, S. K.;Choi, Y.;Im, K. C.;Song, T. Y.;Jung, J. H.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.253-261
    • /
    • 2002
  • A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .

Optimization of H-IPS Structure for High Aperture Ratio.

  • Lee, Do-Young;Kim, Do-Sung;Kang, Byung-Goo;Kim, Eui-Tae;Kim, Bo-Ram;Kim, Jung-Han;Lim, Byung-Ho;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.290-293
    • /
    • 2006
  • We designed the H-IPS that has similar aperture ratio to the AS-IPS with organic insulator. To improve the aperture ratio without organic insulator, we positioned the pixel electrode over the preceding gate on the base of the H-IPS structure, and minimized the width of pixel and common electrodes. Without the additional process, we could obtain the similar brightness with that of AS-IPS in 15inch SXGA+ Panel.

  • PDF

A Study on Improvement of the Transmittance in the Fringe-Field Switching (FFS) Mode

  • Lee, J.Y.;Ryu, J.W.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.621-624
    • /
    • 2006
  • Pixel structure of the fringe-field switching (FFS) mode to improve transmittance has been studied. New FFS structures related to the electrode structure at the edges of pixel, and the pixel electrode width and distance between electrodes was optimized. The former improves transmittance by minimizing the region of disclination lines. The latter improves it by increasing light efficiency above center of electrodes and also response time.

  • PDF

Advanced Cell Structure for High Contrast Ratio in Charge Share S-PVA Monitors

  • Kim, Su-Jeong;Kim, Kwang-Hyun;Jung, Ji-Yoon;Heo, Jeong-Uk;Lee, Nam-Seok;Kim, Kyeong-Hyeon;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.288-291
    • /
    • 2008
  • This paper describes a new S-PVA cell structure which achieves enhanced contrast ratio by adopting a step-like patterned common electrode between the high sub-pixel and low sub-pixel electrodes without loss of transmittance. A 24-inch panel was developed for monitor applications and measured contrast ratio and white luminance were over 2500:1 and 400cd/m2, respectively.

  • PDF

New S-PVA Technology for Advanced LCD Performance

  • Um, Yoon-Sung;Park, Seung-Beom;Kim, Hoon;You, Hye-Ran;Lyu, Jae-Jin;Kim, Kyeong-Hyeon;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.403-406
    • /
    • 2007
  • A New S-PVA which is named as charge-shared super PVA (CS S-PVA) LCD mode is proposed. CS SPVA controls the voltage ratio of low pixel by sharing system between low pixel and control cap, resulting in improved off-axis image quality and transmittance increase without any side effects. Moreover, the new S-PVA LCD mode is free of image-sticking. Operating schemes and display performance of CS S-PVA are presented.

  • PDF

Automatic Interior Orientation of Aerial Photographs with Model-free Condition

  • Cho, Seong-Ik;Kim, Kyoung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.536-541
    • /
    • 2002
  • This paper proposes an approach of automatically calculating the center location of fiducial marks up to sub-pixel accuracy with model-free condition. The conceptual model, composed of two assumptions, about general geometric property of fiducial area and fiducial mark is established. The proposed approach is primarily based on the strategy of calculating the center of symmetry and is composed of three steps of processing: (a) determining horizontal center of fiducial area, (b) locating center of a fiducial mark, and, (c) finally calculating the exact center up to sub-pixel accuracy. Evaluation with respect to RMK style marks and RC style ones shows that the proposed approach can be evaluated as robust one. However there are several images which can't be analyzed by the proposed approach.

  • PDF

The Tracing Algorithm for Center Pixel of Character Image and the Design of Neural Chip (문자영상의 중심화소 추적 알고리즘 및 신경칩 설계)

  • 고휘진;여진경;정호선
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.8
    • /
    • pp.35-43
    • /
    • 1992
  • We have presented the tracing algorithm for center pixel of character image. Character image was read by scanner device. Performing the tracing process, it can be possible to detect feature points, such as branch point, stroke of 4 directions. So, the tracing process covers the thinning and feature point detection process for improving the processing time. Usage of suggested tracing algorithm instead of thinning that is the preprocessing of character recognition increases speed up to 5 times. The preprocessing chip has been designed by using single layer perceptron algorithm.

  • PDF

Shot-change Detection using Hierarchical Clustering (계층적 클러스터링을 이용한 장면 전환점 검출)

  • 김종성;홍승범;백중환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1507-1510
    • /
    • 2003
  • We propose UPGMA(Unweighted Pair Group Method using Average distance) as hierarchical clustering to detect abrupt shot changes using multiple features such as pixel-by-pixel difference, global and local histogram difference. Conventional $\kappa$-means algorithm which is a method of the partitional clustering, has to select an efficient initial cluster center adaptively UPGMA that we propose, does not need initial cluster center because of agglomerative algorithm that it starts from each sample for clusters. And UPGMA results in stable performance. Experiment results show that the proposed algorithm works not only well but also stably.

  • PDF

Improved measurement uncertainty of photon detection efficiency for single pixel Silicon photomultiplier

  • Yang, Seul Ki;Lee, Hye-Young;Jeon, Jina;Kim, Sug-Whan;Lee, Jik;Park, Il H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.210.1-210.1
    • /
    • 2012
  • We report technique used for improved measurement uncertainties for Photon detection efficiency(PDE) of $1mm^2$ single pixel SiPM. It consists of 470nm LED light source, two 2-inch integrating sphere and two NIST calibrated silicon photodiodes that have ${\pm}2.4%$ calibration error. With raytracing simulation of our experimental setup, we predict number of photon into SiPM and measurement uncertainty. For MPPC, Hamamatsu suggested PDE(1600 micro pixel) including crosstalk and afterpulse is 23.5% at 470 nm. By using new low calibration error photodiode and raytracing simulation, our simulation result has ${\pm}3%$ measurement uncertainty. The technical detail of measurement, simulation are presented with the results and implication.

  • PDF