• Title/Summary/Keyword: Center Pin

Search Result 322, Processing Time 0.021 seconds

A Study on Fracture Behavior of Center Crack at Unidirectional CFRP due to Stacking Angle (적층각도에 따른 단방향 CFRP에서의 중앙 크랙의 파괴 거동에 관한 연구)

  • Park, Jae-Woong;Cheon, Seong-Sik;Cho, Jae-Ung
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.342-346
    • /
    • 2016
  • Carbon fiber reinforced plastic (CFRP), one of lightweight materials, is the fiber structure using carbon fiber. It is the composite material that has the characteristics of carbon and plastic. As for the fiber structure, it has the great strength due to fiber direction. CFRP for woven type is used mostly as such a CFRP with lightweight. Woven type is more stable when compared with unidirectional type. On the other hand, woven type is highly priced. Therefore, this study aims to analyze the fiber structure of unidirectional CFRP. In this study, as the stacking angle [0/X/-X/0], X is the variable. This is unidirectional CFRP in which the angle phase of X has been reversed and stacked. By using such a unidirectional CFRP, the analysis model which had a crack at the center as the form of panel with the thickness of 2 mm was used. On analysis, the load is applied on the upper and lower parts being connected with a pin. The damage in the area near center crack was investigated. As for the analysis model, 3D surface model was designed by using CATIA. For CFRP stacking, the stacking direction was determined by using ACP in ANSYS program and the analysis model with two stacks was made. Afterwards, the structural analysis was carried out.

Quality Characteristics of Defatted Soybean Grits Fermented by Bacillus subtilis NUC1 (고초균에 의한 탈지대두 Grits(Defatted Soybean Grits) 발효물의 품질 특성)

  • Kim, Hyun-Jeong;Lee, Sung-Gyu;Ji, Young-Ju;HwangBo, Mi-Hyang;Lee, Eun-Ju;Lee, Sam-Pin;Lee, In-Seon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1479-1484
    • /
    • 2008
  • This study was conducted to investigate the quality characteristics of fermented-defatted soybean grits (DSG). Fermented-DSG was prepared by inoculating Bacillus subtilis NUCI into steamed DSG at 2% (v/w) concentration and fermenting at $40^{\circ}C$ for 24 hr. The protein contents of DSG and fermented-DSG were higher by $57.2{\sim}61.0%$ than those of Chungkukjang, but lipid contents of these samples were not detected. The protease and $\alpha$-amylase activities, and solid contents in DSG were not shown. However, the activities of protease and $\alpha$-amylase, tyrosine contents, fluid consistency, and viscous substance contents of fermented-DSG were higher than those of Chungkukjang. The levels of free amino acids and isoflavone of fermented-DSG tended to increase more than those of DSG. The sensory score of fermented-DSG were higher in odor and taste than those of Chungkukjang groups, while lower in color and overall acceptability.

Cholesterol Improvement Effects of Fermented Defatted Soybean Grits Added to Corchorus olitorius (몰로키아 첨가 탈지대두grit(defatted soybean grit) 발효물의 콜레스테롤 개선 효과)

  • Kim, Hyun-Jeong;Lee, Sung-Gyu;Lee, Sam-Pin;Lee, In-Seon
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.3
    • /
    • pp.375-380
    • /
    • 2011
  • This study was performed to investigate cholesterol improvement effects of adding fermented defatted soybean grit (FD) and FD added to 5 or 10% Corchorus olitorius (FDC). Cholesterol adsorption in the FD and FDC group was more than 70%. Apolipoprotein AI and CIII improved in HepG2 cells, and a greater improvement effect was shown in FDC than that in FD. We also investigated the effect of FDC on body lipid metabolism and a high-fat diet for 4 weeks. Rats were divided into control (Con), high-fat (HF), HF treated with 20% FD (HF-FD), and HF treated with 20% FDC (HF-FDC) groups. Plasma total cholesterol and low density lipoprotein-cholesterol concentrations, hepatic total cholesterol, and triglyceride contents were significantly lower in the HF-FDC group than those in the HF group. Additionally, fecal total cholesterol and triglyceride contents increased in rats treated with FDC. Hepatic 3-hydroxy-3-methylglutaryl-coenzyme A reductase activities were significantly lower in the HF-FDC group than those in the HF group.

A Study on the Electroplating using Macroemulsion in High Pressure (고압 매크로에멀젼을 이용한 전해도금에 관한 연구)

  • Park, Ji-Young;Yang, Jun Youl;Suh, Dong Jin;Yoo, Ki-Pung;Lim, Jong Sung
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.53-59
    • /
    • 2005
  • In this study, the supercritical electroplating was investigated by forming macroemulsion of electroplating solution using surfactant in supercritical $CO_2$. The fluorinated analogous AOT surfactant, sodium salt of bis (2,2,3,3,4,4,5,5-octafluoro-1-pentanol) sulfosuccinate which has both '$CO_2$ philic' chains and 'hydrophilic' head group was used as a surfactant, and Ni plate and Cu plate were used as the anode and the cathode, respectively. Electroplating was carried out in the conventional method and the supercritical macroemulsion and both results were compared. The supercritical electroplating was carried out in various concentration of surfactant such as 2, 4, 7 wt%, the volume ratio of Ni-plating solution to $CO_2$ was varied in the range of 10-70 vol%, and propane was used as a supercritical fluid instead of $CO_2$. According to the experimental results, the plated surface of Ni on Cu plate performed in supercritical macroemulsion was better than that, in conventional state. In the image of Ni surface plated on Cu plate in supercritical state, there were fewer pin-holes and pits comparing with that in the conventional process. The current and conductivity was increased as the volume ratio of Ni-plating solution to $CO_2$ was increased and the current and the amount of Ni plated on Cu plate were decreased as the concentration of surfactant become higher. In addition, in case of the continuous phase, using $CO_2$ was more effective than using $CO_2$.

Repair of Unilateral Cleft Lip and Nose: Mulliken's Modification of Rotation Advancement (편측 구순열비의 교정술: Rotation Advancement 원칙에 근거한 Mulliken의 방법)

  • Jung, Young-Soo;Lee, Gyu-Tae;Jung, Hwi-Dong;Mulliken, John B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • This is a review regarding Mulliken's Modification using the Millard rotation-advancement principle for the repair of unilateral complete cleft lip and nasal deformity. All patients underwent prior labionasal adhesion and dentofacial orthopedics with a pin-retained (Latham) appliance used for infants with a cleft of the lip and palate. Technical variations concerning the operation are described. A high rotation and releasing incision in the columella lengthens the medial labial element and produces a symmetric prolabium with minimal transgression of the upper philtral column through the advancement flap. The orbicularis oris muscle is everted, from caudad to cephalad, to form the philtral ridge. A minor variation of unilimb Z-plasty is used to level the cleft side of Cupid's bow handle, and cutaneous closure proceeds superiorly from this junction. The dislocated alar cartilage is visualized though a nostril rim incision and suspended to the ipsilateral upper lateral cartilage. Symmetry of the alar base is addressed in three dimensions, including maneuvers to position the deviated anterior-caudal septum, configure the sill, and efface the lateral vestibular web. The authors believe the technical refinements described herein contribute favorably to the outcome of repair regarding unilateral cleft lip and nasal distortion.

Evaluation of the Chemical Compositions of Solar Salts Produced in Korea (국내 시판 천일염의 성분 조사)

  • Seo, Ji-Hyun;Kim, Hyun-Jeong;Lee, Sam-Pin
    • Food Science and Preservation
    • /
    • v.19 no.4
    • /
    • pp.554-559
    • /
    • 2012
  • To evaluate the effect of aging on solar salts produced in Korea, the chemical compositions of the solar salts, including their heavy metal contents, were analyzed after they were aged for one-year (OA) and for three years (TA). The average contents of the components were: sodium chloride; 81.4% (OA) and 90.9% (TA), chloride; 57.7% (OA) and 65.0% (TA), moisture content; 4.7% (TA) and 12.0% (OA), insoluble solids; 0.03% (OA) and 0.04% (TA), and $SO_4$ ions; and 0.57% (TA) and 0.85% (OA). No significant difference was found, however, in the heavy metal contents. Heavy metals such as As, Pb, and Hg were detected with values far below the maximum permissible limit, and Cd was not detected in the salts. The TA solar salts showed higher values of sodium chloride, chloride, and insoluble solids than the OA solar salts, but the TA solar salts had lower moisture and $SO_4$ values. These results clearly indicate that the levels of heavy metals in the OA and TA solar salts that are produced in Korea are safe.

Clinical Outcomes and Cost-Effectiveness of Osteoporosis Screening With Dual-Energy X-ray Absorptiometry

  • Chiao-Lin Hsu;Pin-Chieh Wu;Chun-Hao Yin;Chung-Hwan Chen;King-Teh Lee;Chih-Lung Lin;Hon-Yi Shi
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1249-1259
    • /
    • 2023
  • Objective: This study aimed to evaluate the clinical outcomes and cost-effectiveness of dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. Materials and Methods: Eligible patients who had and had not undergone DXA screening were identified from among those aged 50 years or older at Kaohsiung Veterans General Hospital, Taiwan. Age, sex, screening year (index year), and Charlson comorbidity index of the DXA and non-DXA groups were matched using inverse probability of treatment weighting (IPTW) for propensity score analysis. For cost-effectiveness analysis, a societal perspective, 1-year cycle length, 20-year time horizon, and discount rate of 2% per year for both effectiveness and costs were adopted in the incremental cost-effectiveness (ICER) model. Results: The outcome analysis included 10337 patients (female:male, 63.8%:36.2%) who were screened for osteoporosis in southern Taiwan between January 1, 2012, and December 31, 2021. The DXA group had significantly better outcomes than the non-DXA group in terms of fragility fractures (7.6% vs. 12.5%, P < 0.001) and mortality (0.6% vs. 4.3%, P < 0.001). The DXA screening strategy gained an ICER of US$ -2794 per quality-adjusted life year (QALY) relative to the non-DXA at the willingness-to-pay threshold of US$ 33004 (Taiwan's per capita gross domestic product). The ICER after stratifying by ages of 50-59, 60-69, 70-79, and ≥ 80 years were US$ -17815, US$ -26862, US$ -28981, and US$ -34816 per QALY, respectively. Conclusion: Using DXA to screen adults aged 50 years or older for osteoporosis resulted in a reduced incidence of fragility fractures, lower mortality rate, and reduced total costs. Screening for osteoporosis is a cost-saving strategy and its effectiveness increases with age. However, caution is needed when generalizing these cost-effectiveness results to all older populations because the study population consisted mainly of women.

Evaluation of The Moment Resistance of Reinforced Wooden Gusset to Glulam Joint (보강목질적층판이 사용된 집성재 접합부의 모멘트 저항성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-61
    • /
    • 2017
  • In this study, specimens were produced with a column member and a wooden gusset only by inserting an wooden gusset which is a substitute for steel plate into the center of a slit-processed column member. The moment resistance performance of the specimens was compared with that of control specimens that used a steel plate. The measured maximum moments of the specimens produced with GFRP-reinforced wooden laminated gussets and pins were lower by 24% on average compared to the steel plate-inserted specimens, but they showed good toughness. The fracture shape suggests that it was fractured along the annual rings between the pin and the end of the column member. The rigid specimen that integrated a laminated wood and a wooden laminated gusset with adhesive showed 2.8 times greater initial rigidity and 40% greater maximum moment on average compared to the control specimen. The rigid specimens mainly fractured on a glulam around glue line.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF