Carbon fiber reinforced plastic (CFRP), one of lightweight materials, is the fiber structure using carbon fiber. It is the composite material that has the characteristics of carbon and plastic. As for the fiber structure, it has the great strength due to fiber direction. CFRP for woven type is used mostly as such a CFRP with lightweight. Woven type is more stable when compared with unidirectional type. On the other hand, woven type is highly priced. Therefore, this study aims to analyze the fiber structure of unidirectional CFRP. In this study, as the stacking angle [0/X/-X/0], X is the variable. This is unidirectional CFRP in which the angle phase of X has been reversed and stacked. By using such a unidirectional CFRP, the analysis model which had a crack at the center as the form of panel with the thickness of 2 mm was used. On analysis, the load is applied on the upper and lower parts being connected with a pin. The damage in the area near center crack was investigated. As for the analysis model, 3D surface model was designed by using CATIA. For CFRP stacking, the stacking direction was determined by using ACP in ANSYS program and the analysis model with two stacks was made. Afterwards, the structural analysis was carried out.
Kim, Hyun-Jeong;Lee, Sung-Gyu;Ji, Young-Ju;HwangBo, Mi-Hyang;Lee, Eun-Ju;Lee, Sam-Pin;Lee, In-Seon
Journal of the Korean Society of Food Science and Nutrition
/
v.37
no.11
/
pp.1479-1484
/
2008
This study was conducted to investigate the quality characteristics of fermented-defatted soybean grits (DSG). Fermented-DSG was prepared by inoculating Bacillus subtilis NUCI into steamed DSG at 2% (v/w) concentration and fermenting at $40^{\circ}C$ for 24 hr. The protein contents of DSG and fermented-DSG were higher by $57.2{\sim}61.0%$ than those of Chungkukjang, but lipid contents of these samples were not detected. The protease and $\alpha$-amylase activities, and solid contents in DSG were not shown. However, the activities of protease and $\alpha$-amylase, tyrosine contents, fluid consistency, and viscous substance contents of fermented-DSG were higher than those of Chungkukjang. The levels of free amino acids and isoflavone of fermented-DSG tended to increase more than those of DSG. The sensory score of fermented-DSG were higher in odor and taste than those of Chungkukjang groups, while lower in color and overall acceptability.
Kim, Hyun-Jeong;Lee, Sung-Gyu;Lee, Sam-Pin;Lee, In-Seon
Korean Journal of Food Science and Technology
/
v.43
no.3
/
pp.375-380
/
2011
This study was performed to investigate cholesterol improvement effects of adding fermented defatted soybean grit (FD) and FD added to 5 or 10% Corchorus olitorius (FDC). Cholesterol adsorption in the FD and FDC group was more than 70%. Apolipoprotein AI and CIII improved in HepG2 cells, and a greater improvement effect was shown in FDC than that in FD. We also investigated the effect of FDC on body lipid metabolism and a high-fat diet for 4 weeks. Rats were divided into control (Con), high-fat (HF), HF treated with 20% FD (HF-FD), and HF treated with 20% FDC (HF-FDC) groups. Plasma total cholesterol and low density lipoprotein-cholesterol concentrations, hepatic total cholesterol, and triglyceride contents were significantly lower in the HF-FDC group than those in the HF group. Additionally, fecal total cholesterol and triglyceride contents increased in rats treated with FDC. Hepatic 3-hydroxy-3-methylglutaryl-coenzyme A reductase activities were significantly lower in the HF-FDC group than those in the HF group.
Park, Ji-Young;Yang, Jun Youl;Suh, Dong Jin;Yoo, Ki-Pung;Lim, Jong Sung
Korean Chemical Engineering Research
/
v.43
no.1
/
pp.53-59
/
2005
In this study, the supercritical electroplating was investigated by forming macroemulsion of electroplating solution using surfactant in supercritical $CO_2$. The fluorinated analogous AOT surfactant, sodium salt of bis (2,2,3,3,4,4,5,5-octafluoro-1-pentanol) sulfosuccinate which has both '$CO_2$ philic' chains and 'hydrophilic' head group was used as a surfactant, and Ni plate and Cu plate were used as the anode and the cathode, respectively. Electroplating was carried out in the conventional method and the supercritical macroemulsion and both results were compared. The supercritical electroplating was carried out in various concentration of surfactant such as 2, 4, 7 wt%, the volume ratio of Ni-plating solution to $CO_2$ was varied in the range of 10-70 vol%, and propane was used as a supercritical fluid instead of $CO_2$. According to the experimental results, the plated surface of Ni on Cu plate performed in supercritical macroemulsion was better than that, in conventional state. In the image of Ni surface plated on Cu plate in supercritical state, there were fewer pin-holes and pits comparing with that in the conventional process. The current and conductivity was increased as the volume ratio of Ni-plating solution to $CO_2$ was increased and the current and the amount of Ni plated on Cu plate were decreased as the concentration of surfactant become higher. In addition, in case of the continuous phase, using $CO_2$ was more effective than using $CO_2$.
Jung, Young-Soo;Lee, Gyu-Tae;Jung, Hwi-Dong;Mulliken, John B.
Maxillofacial Plastic and Reconstructive Surgery
/
v.34
no.2
/
pp.133-139
/
2012
This is a review regarding Mulliken's Modification using the Millard rotation-advancement principle for the repair of unilateral complete cleft lip and nasal deformity. All patients underwent prior labionasal adhesion and dentofacial orthopedics with a pin-retained (Latham) appliance used for infants with a cleft of the lip and palate. Technical variations concerning the operation are described. A high rotation and releasing incision in the columella lengthens the medial labial element and produces a symmetric prolabium with minimal transgression of the upper philtral column through the advancement flap. The orbicularis oris muscle is everted, from caudad to cephalad, to form the philtral ridge. A minor variation of unilimb Z-plasty is used to level the cleft side of Cupid's bow handle, and cutaneous closure proceeds superiorly from this junction. The dislocated alar cartilage is visualized though a nostril rim incision and suspended to the ipsilateral upper lateral cartilage. Symmetry of the alar base is addressed in three dimensions, including maneuvers to position the deviated anterior-caudal septum, configure the sill, and efface the lateral vestibular web. The authors believe the technical refinements described herein contribute favorably to the outcome of repair regarding unilateral cleft lip and nasal distortion.
To evaluate the effect of aging on solar salts produced in Korea, the chemical compositions of the solar salts, including their heavy metal contents, were analyzed after they were aged for one-year (OA) and for three years (TA). The average contents of the components were: sodium chloride; 81.4% (OA) and 90.9% (TA), chloride; 57.7% (OA) and 65.0% (TA), moisture content; 4.7% (TA) and 12.0% (OA), insoluble solids; 0.03% (OA) and 0.04% (TA), and $SO_4$ ions; and 0.57% (TA) and 0.85% (OA). No significant difference was found, however, in the heavy metal contents. Heavy metals such as As, Pb, and Hg were detected with values far below the maximum permissible limit, and Cd was not detected in the salts. The TA solar salts showed higher values of sodium chloride, chloride, and insoluble solids than the OA solar salts, but the TA solar salts had lower moisture and $SO_4$ values. These results clearly indicate that the levels of heavy metals in the OA and TA solar salts that are produced in Korea are safe.
Chiao-Lin Hsu;Pin-Chieh Wu;Chun-Hao Yin;Chung-Hwan Chen;King-Teh Lee;Chih-Lung Lin;Hon-Yi Shi
Korean Journal of Radiology
/
v.24
no.12
/
pp.1249-1259
/
2023
Objective: This study aimed to evaluate the clinical outcomes and cost-effectiveness of dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. Materials and Methods: Eligible patients who had and had not undergone DXA screening were identified from among those aged 50 years or older at Kaohsiung Veterans General Hospital, Taiwan. Age, sex, screening year (index year), and Charlson comorbidity index of the DXA and non-DXA groups were matched using inverse probability of treatment weighting (IPTW) for propensity score analysis. For cost-effectiveness analysis, a societal perspective, 1-year cycle length, 20-year time horizon, and discount rate of 2% per year for both effectiveness and costs were adopted in the incremental cost-effectiveness (ICER) model. Results: The outcome analysis included 10337 patients (female:male, 63.8%:36.2%) who were screened for osteoporosis in southern Taiwan between January 1, 2012, and December 31, 2021. The DXA group had significantly better outcomes than the non-DXA group in terms of fragility fractures (7.6% vs. 12.5%, P < 0.001) and mortality (0.6% vs. 4.3%, P < 0.001). The DXA screening strategy gained an ICER of US$ -2794 per quality-adjusted life year (QALY) relative to the non-DXA at the willingness-to-pay threshold of US$ 33004 (Taiwan's per capita gross domestic product). The ICER after stratifying by ages of 50-59, 60-69, 70-79, and ≥ 80 years were US$ -17815, US$ -26862, US$ -28981, and US$ -34816 per QALY, respectively. Conclusion: Using DXA to screen adults aged 50 years or older for osteoporosis resulted in a reduced incidence of fragility fractures, lower mortality rate, and reduced total costs. Screening for osteoporosis is a cost-saving strategy and its effectiveness increases with age. However, caution is needed when generalizing these cost-effectiveness results to all older populations because the study population consisted mainly of women.
In this study, specimens were produced with a column member and a wooden gusset only by inserting an wooden gusset which is a substitute for steel plate into the center of a slit-processed column member. The moment resistance performance of the specimens was compared with that of control specimens that used a steel plate. The measured maximum moments of the specimens produced with GFRP-reinforced wooden laminated gussets and pins were lower by 24% on average compared to the steel plate-inserted specimens, but they showed good toughness. The fracture shape suggests that it was fractured along the annual rings between the pin and the end of the column member. The rigid specimen that integrated a laminated wood and a wooden laminated gusset with adhesive showed 2.8 times greater initial rigidity and 40% greater maximum moment on average compared to the control specimen. The rigid specimens mainly fractured on a glulam around glue line.
Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
Tribology and Lubricants
/
v.21
no.6
/
pp.268-271
/
2005
In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.
Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
/
2004.11a
/
pp.350-354
/
2004
In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.