Psychosocial Interventions for Children and Adolescents after a Disaster: A Systematic Literature Review (1991-2015) (재난 후 소아청소년의 정신사회적 개입: 체계적 문헌고찰(1991~2015))

  • Lee, Mi-Sun;Hwang, Jun-Won;Lee, Cheol-Soon;Kim, Ji-Youn;Lee, Ju-Hyun;Kim, Eunji;Chang, Hyoung Yoon;Bae, Seung-Min;Park, Jang-Ho;Bhang, Soo-Young
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.4
    • /
    • pp.278-305
    • /
    • 2016
  • Objective: The aim of this systematic literature review is to analyze the psychosocial interventions for children and adolescents after disasters. Methods: We conducted a review of the extant research literature from 1991 to 2015 via a comprehensive search of the MEDLINE, EMBASE, Cochrane CENTRAL, PubMed and PsyclNFO databases. The keywords employed in this research included: 'child', 'adolescent', 'youth', 'disaster', 'posttraumatic', 'psychosocial', 'therapy' and 'intervention'. The researchers followed the PRISMA guidelines. A total of 850 articles were screened for their eligibility and fifty-nine were found to meet the study criteria. The final data analysis was performed based on the disaster type, study design, type of intervention, sample size, age, school grade, number of sessions, setting of intervention delivery, providers, approach and parent involvement. Results: Countries worldwide have experienced various kinds of disasters, including earthquakes, hurricanes, vessel accidents, tornados, tsunamis, volcanic eruptions, war, fire, terrorism, and traffic accidents. The types of psychosocial intervention that were conducted after these disasters included: psychological first aid, psychological debriefing, psychoeducation, trauma focused cognitive behavior therapy, eye movement desensitization reprocessing, prolonged exposure therapy, group play therapy and arts therapy, project interventions, school-based interventions and web-based interventions. Conclusion: The findings of the systematic literature review suggest that an appropriate psychosocial intervention could be utilized as evidence-based mental health treatment for children and adolescents after disasters.

A Study on the Residual Mechanical Properties of Fiber Reinforced Concrete with High Temperature and Load (고온 및 하중에 따른 섬유보강 콘크리트의 잔존 역학적 특성에 관한 연구)

  • Kim, Young-Sun;Lee, Tae-Gyu;Nam, Jeong-Soo;Park, Gyu-Yeon;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.321-330
    • /
    • 2011
  • Recently, the effects of high temperature and fiber content on the residual mechnical properties of high-strength concrete were experimentally investigated. In this paper, residual mechanical properties of concrete with water to cement (w/c) ratios of 0.55, 0.42 and 0.35 exposed to high temperature are compared with those obtained in fiber reinforced concrete with similar characteristics ranging from 0.05% to 0.20% polypropylene (PP) fiber volume percentage. Also, factors including pre-load levels of 20% and 40% of the maximum load at room temperature are considered. Outbreak time, thermal strain, length change, and mass loss were tested to determine compressive strength, modulus of elasticity, and energy absorption capacity. From the results, in order to prevent the explosive spalling of 50 MPa grade concretes exposed to high temperature, more than 0.05 vol. % of PP fibers is needed. Also, the cross-sectional area of PP fiber can influence the residual mechanical properties and spalling tendency of fiber reinforced concrete exposed to high temperature. Especially, the external loading increases not only the residual mechanical properties of concrete but also the risk of spalling and brittle failure tendency.

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Blast Resistance Behavior under Blast Loading Scenario (폭발하중 시나리오에 따른 2방향 비부착 프리스트레스트 콘크리트 패널부재의 폭발저항성능에 대한 실험적 거동 평가)

  • Choi, Ji-Hun;Choi, Seung-Jai;Cho, Chul-Min;Kim, Tae-Kyun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.673-683
    • /
    • 2016
  • In recent years, frequent terror or military attack by explosion, impact, fire accidents have occurred. Particularly, World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. Also, nuclear power plant incident on Mar. 11 of 2011. These attacks and incidents were raised public concerns and anxiety of potential terrorist attacks on major infrastructures and structures. Therefore, the extreme loading researches were performed of prestressed concrete (PSC) member, which widely used for nuclear containment vessel and gas tank. In this paper, to evaluate the blast resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, blast tests were carried out on $1,400{\times}1,000{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PSC), prestressed concrete with rebar (PSRC) specimens. The applied blast load was generated by the detonation of 55 lbs ANFO explosive charge at 1.0 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included displacement, acceleration, and strains at steel, concrete, PS tendon. The results can be used as basic research references for related research areas, which include protective design and blast simulation under blast loading.

The LVC Linkage for the Interoperability of the Battle Lab (Battle Lab에서의 상호운용성을 위한 LVC 연동방안)

  • Yun, Keun-Ho;Shim, Shin-Woo;Lee, Dong-Joon
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.1
    • /
    • pp.81-88
    • /
    • 2012
  • In the M&S filed, The Battle Lab is available for acquisition, design, development tool, validation test, and training in the weapon system of development process. Recently, the Battle Lab in the military of Korea is still in an early stage, in spite of importance of battle lab construction. In the environment of network centric warfare, a practical use of the M&S which is connecting live, virtual and constructive model can be applied to all field of System Engineering process. It is necessary thar the Battle Lab is not restricted by time and space, and is possible for the technical implementation. In this paper, to guarantee the interoperability of live and virtual simulation, virtual simulators connect live simulators by using the tactical data link. To guarantee the interoperability of virtual and constructive simulation, both virtual simulators and constructive simulators use the RTI which is the standard tool of M&S. We propose the System that constructed the Air Defence Battle Lab. In case of the approach of target tracks, The Air Defence Battle Lab is the system for the engagement based on a command of an upper system in the engagement weapon system. Constructive simulators which are target track, missile, radar, and launcher simulator connect virtual simulators which are MCRC, battalion, and fire control center simulators using the RPR-FOM 1.0 that is a kind of RTI FOM. The interoperability of virtual simulators and live simulators can be guaranteed by the connection of the tactical data links which are Link-11B and ATDL-1.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

Removal of Volatile Organic Compounds (VOCs) of Deodorant by Adding a Metal Oxide to the Essential Oils (식물정유물질에 금속산화물을 첨가한 탈취제의 휘발성유기화합물질의 제거에 관한 연구)

  • Lim, You-Young;Lee, Min-Ho;Jeon, Soo-Bin;Yang, Kyeong-Soon;Jeong, Hae-Eun;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.96-105
    • /
    • 2016
  • VOCs emissions from industries cause the air pollution and odor. In the industrial facilities, the existing odor treatment techniques have limits and problems. In this study, the optimum essential oil and metal oxide selected by screening test. lavender oil, cypress oil and TiO2 were determined by deodorant materials and those were blended by 5%, 45%, 10%, respectively. In addition, the result of batch type experiments depending on the dilution rate, injection, rate, temperature showed that the optimum condition of deodorant is 6 mL of injection rate, and 200 times of dilution rate and the removal efficiency increased in proportion with temperature. In addition, the activation energy was calculated from the rate equation, which appeared in the 3-4 times lower than conventional deodorants.

Numerical Simulation of Full-Scale Crash Impact Test for Fuel Cell of Rotorcraft (회전익항공기 연료셀 충돌충격시험 Full-Scale 수치모사)

  • Kim, Hyun-Gi;Kim, Sung Chan;Kim, Sung Jun;Kim, Soo Yeon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.343-349
    • /
    • 2013
  • Crashworthy fuel cells have a great influence on improving the survivability of crews. Since 1960's, the US army has developed a detailed military specification, MIL-DTL-27422, defining the performance requirements for rotorcraft fuel cells. In the qualification tests required by MIL-DTL-27422, the crash impact test should be conducted to verify the crashworthiness of fuel cell. Success of the crash impact test means the improvement of survivability of crews by preventing post-crash fire. But, there is a big risk of failure due to huge external load in the crash impact test. Because the crash impact test itself takes a long-term preparation efforts together with costly fuel cell specimens, the failure of crash impact test can result in serious delay of a entire rotorcraft development. Thus, the numerical simulations of the crash impact test has been required at the early design stage to minimize the possibility of trial-and-error with full-scale fuel cells. Present study performs the numerical simulation using SPH(smoothed particle hydro-dynamic) method supported by a crash simulation software, LS-DYNA. Test condition of MIL-DTL-27422 is reflected on analysis and material data is acquired by specimen test of fuel cell material. As a result, the resulting equivalent stresses of fuel cell itself are calculated and vulnerable areas are also evaluated.

The Method of Evaluating The Potential for Conversion Legal Problems with Conversion And Basic Capacity of Vacant Onces in Tokyo

  • Sato, Kouichi;Matsumura, Shuichi;Namiki, Kenji
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.301-306
    • /
    • 2002
  • In Japan, the vacancy rates of office buildings have been at high in big cities since 1992. This problem is especially acute in Tokyo, where it is estimated that over 2.27 million square meters of office floor area will be oversupplied in 2003: big urban redevelopment projects will be completed in 2003. Under these circumstances, International Cooperative Research and Development on Sustainable Urban Management by Conversion of Buildings, called “SUMCOB”, has been carried out. This research aims to regenerate urban areas by converting redundant offices into flats, although instances of conversion are still very few in Japan. This paper introduces part of current results by SUMCOB, and discusses legal problems with conversion and basic capacity of vacant offices in Tokyo. It has been confirmed that there are no constraints concerned with Real Estate Registration Law (although it requires the change of the registration after conversion). and City Planning Law. However, some criteria are incompatible with Building Standard Law and Fire Service Law if the use of the building is changed from offices to flats. Typical incompatibility between offices and flats is lightening. If the buildings do not satisfy criteria for flats, the cost of renovation works for conversion will increase. To examine the basic capacity of vacant office buildings for conversion, field surveys in Tokyo have carried out at three areas: Kodenmacho (Chuo-ku), Toranomon (Minato-ku), and Iwamonocho (Chiyoda-ku). They are typical office areas that are included in center core of Tokyo. In Chuo-ku, the oldest commercial area in Tokyo, textile merchants have been located their headquarters. In Minato-ku, many rental office buildings have been located and several large scale redevelopments are advancing. Chiyoda-ku includes Marunouchi area, which is the prime office area in Japan. Thirty percent of the buildings in survey areas suffer from over twenty percent vacant floor rate, and fifty five percent were constructed before 1990. Especially most of buildings over forty percent vacant floor rate were constructed in 1980s. Vacant office problems haven't been seen in old buildings in Tokyo yet. The number of dwelling units made from office space will influence the conversion scheme. Seventy percent of the office buildings in survey areas have floor area of less than two hundred square meters. If they have been subdivided into two bedrooms type or three bedrooms type, the number of dwelling units in a floor would be less than three. The difficulty of conversion planning derives from frontage size, depth size, and their proportion. The five categories are proposed to grasp actual requirements for converting offices into flats.

  • PDF

An Analysis on the Prehospital Care of 119 Emergency Medical Service squads in Gyeonggi Area and Improvement Methods - Focusing on Prehospital Care - (경기도지역 119안전센터의 구급활동 현황과 개선방안 - 현장 응급처치 내역을 중심으로 -)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.55-69
    • /
    • 2008
  • Purpose : The purpose of this study was to analyze the prehospital care report prepared by EMS squads of 119 center in Gyeonggi area and to identify the status of prehospital care activities, problems and improvement possibilities of the emergency care. Method : Five hundred copies of prehospital care report prepared by EMS squads in thirty-eight 119 centers under 18 fire stations in Gyeonggi area from March to April in 2008 were randomly chosen for the analysis. Data abstracted according to the purpose of the study were input and the analysis of prehospital care activities were performed using SPSS-WIN(ver. 16) statistics package. Results : 1. Total 500 cases of prehospital emergency care activities were reviewed. By sex, females were 219 (43.8%) and males were 281 (56.2%). The places of reporting were home (57.8%). According to the type of emergency, 281 cases (56.2%) were caused by disease and 291 (43.8%) were from other causes such as traffic accidents or incidental injuries. 2 The average time needed for the 119 EMS squad to arrive at the scene after being reported was 7.29 minutes. The time used at the scene for the emergency care was 7.3 minutes in average and the time to arrive at the hospital was 25.4 minutes in average. 3. In patient evaluation, in 68% of the cases more than two vital signs were measured at one time and emergency patients were 31%, and non-emergency patients were 69%. 4. In one EMS activity, average 2.15 cases of emergency care were provided to a patient. The cases where two kinds of emergency care were given were 14.4%, which is the most frequent cases. When reviewing the details of the emergency cares given to the patient including multiple cares, trivial cards (taking it easy and giving comfort) were the most frequent one as 40.6% and the medical direction of the doctor was given in only one case out of 500 cases. 5. In patient evaluation and emergency care, vital signs were provided to emergency patients at significantly higher rate comparing to the non-emergency patients. The number of emergency care performance was significantly higher in emergency cases. In emergency dispatch, the cases that EMT (1st class) was on board was 86.2%. When comparing the cases when the 1st class EMT was on board and otherwise, the cases with the presence of 1st class EMT showed more vital signs were detected but there was no significant difference in the number of emergency cares provided. Conclusion : It seemed that the on-scene emergency care did not satisfy the expectations. So it is necessary to enforce the cooperation between the elements, the qualifications of the 119 EMS squads and to improve the prehospital working environment in order to provide the better medical service at any time.

  • PDF

Electrical Properties of BaTiO3-based 0603/0.1µF/0.3mm Ceramics Decoupling Capacitor for Embedding in the PCB of 10G RF Transceiver Module

  • Park, Hwa-sun;Na, Youngil;Choi, Ho Joon;Suh, Su-jeong;Baek, Dong-Hyun;Yoon, Jung-Rag
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1638-1643
    • /
    • 2018
  • Multi-layer ceramic capacitors as decoupling capacitor were fabricated by dielectric composition with a high dielectric constant. The fabricated decoupling capacitors were embedded in the PCB of the 10G RF transceiver module and evaluated for the characteristics of electrical noise by the level of AC input voltage. In order to further improve the electrical properties of the $BaTiO_3$ based composite, glass frit, MgO, $Y_2O_3$, $Mn_3O$, $V_2O_5$, $BaCO_3$, $SiO_2$, and $Al_2O_3$ were used as additives. The electrical properties of the composites were determined by various amounts of additives and optimum sintering temperature. As a result of the optimized composite, it was possible to obtain a density of $5.77g/cm^3$, a dielectric constant of 1994, and an insulation resistance of $2.91{\times}10^{12}{\Omega}$ at an additive content of 5wt% and a sintering temperature of $1250^{\circ}C$. After forming a $2.5{\mu}m$ green sheet using the doctor blade method, a total of 77 layers were laminated and sintered at $1180^{\circ}C$. A decoupling capacitor with a size of $0.6mm(W){\times}0.3mm(L){\times}0.3mm(T)$ (width, length and thickness, respectively) and a capacitance of 100 nF was embedded using a PCB process for the 10G RF Transceiver modules. In the range of AC input voltage 400mmV @ 500kHz to 2200mV @ 900kHz, the embedded 10G RF Transceiver modules evaluated that it has better electrical performance than the non-embedded modules.