• Title/Summary/Keyword: Celluloid

Search Result 33, Processing Time 0.025 seconds

GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH (강화형 strip crown의 사용)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.132-135
    • /
    • 2005
  • The purpose of this study was to propose the modified strip crown technique for esthetic restoration of primary anterior teeth using glass fibers. Celluloid crown form(3M, USA), Z100(P shade, 3M, USA). Aeliteflo(Bisco Inc., USA), and Clearfil SE Bond(Kuraray Medical Inc., Japan) were used for this technique. Mesh type of glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA) was used for reinforcing material. After trimming the celluloid crown form, resin adhesive and flowable resin were applied on the pre-shaped glass fiber mesh. That mesh was placed on the lingual surface of inside of celluloid crown form and followed by light activation. Composite resin was filled into the celluloid crown form and put it on a prepared tooth and then light activated and finished the margin. The new modified strip crown technique can provide esthetics and increased durability for restoration of primary anterior teeth.

  • PDF

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

A STUDY OF SURFACE ROUGHNESS OF COMPOSITE RESIN (복합레진의 표면조도에 관한 연구)

  • Park, Ki-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.108-115
    • /
    • 2000
  • This study was designed to compare the effect of polishing on surface roughness of composite resin. We used Z100(3M) composite resin and placed the composite resin in the hole (4mm thick and 4mm in diameter) of vinyl plate and polymerized it under manufacturer's instructions. Samples were divided into 5 groups by polishing methods. Group 1 was control: resin was polymerized under glass plate, Group 2: resin was polymerized without any polishing procedure, Group 3: resin was polymerized with a polishing procedure of abrasive disc, Group 4: bonding agent was applyed in thin layer and polymerized on the polished polymerized resin surface. Group 5: resin was polymerized under transparent celluloid strip. The surface roughness of each specimen was measured with Sufacoder SEF-30D (Kosaka lab. Ltd) under 0.08mm cut off, 0.05mm/s stylus speed, ${\times}40$ horizontal magnification, ${\times}5000$ vertical magnification. The results were as follows : 1. Group 1 showed the most smooth surface in this study. 2. Group 3 showed more rough surface than Group 2. Considering the surface roughness, it would be better to make the shape completely before polymerize the resin. To finish and polish after the polymerization of resin makes less smooth surface. 3. When we use the transparent celluloid strip, minimum finishing procedures are recommended. Any polishing procedure could not recover the smooth resin surface of celluloid strip. 4. Application and polymerization of the thin layer of bonding agent on the polished surface showed the minimum surface smoothing effect.

  • PDF

A STUDY ON THE ROUGHNESS OF THE VISIBLE LIGHT CURED COMPOSITE RESINS (가시광선(可視光線) 중합형(重合型) 복합(複合)레진의 표면조도(表面粗度)에 관(關)한 연구(硏究))

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.197-212
    • /
    • 1991
  • The purpose of this study was to roughness on the polished surface of visible light composite resins and was to observe the polished surfaces under Scanning Electrom Microscope(ISI DS 130 AKASHI Co. JAPAN). The surface roughness tester(Surfcom 700A Seimtsu profilometer Tokyo, Japan) was used to measure roughness of polished surfaces. In this study, 5 brands of visible of composite resins were examined, Pyrofile light bond Anterior Lite fil anterior Photo clearfil anterior & posterior Palfique light Anterior and posterior Silux Anterior. White point, Silicure point, Super snap Sof-Lex medium disk as cutting instrument, and celluloid matrix were used. The results obtained were as follows. 1. The Celluloid matrix produced the smoothest surfaces. 2. The surfaces made by Soflex medium disk was smoother than the surfaces made by any other polishing instruments. 3. The values of surface roughness made by White point, Silicon point and Super snap were similer. 4. Palfique light (AP) visible light composite resin showed the smoothest surface after polishing with Silicone point, Super snap disk and Soflex mediuem disk in all tested materials.

  • PDF

A STUDY ON THE ROUGHNESS OF THE RESTORATIVE COMPOSITE RESIN (수복용(修複用) 복합(復合)레진의 표면조도(表面粗度)에 관(關)한 연구(硏究))

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.207-220
    • /
    • 1988
  • The purpose of this study was to measure roughness on the polished surfaces of composite resin, and was to observe the polished surfaces under Scanning Electron Microscope. The surface roughness tester (Surfcom 700A Semitsu Profilometer Tokyo. Japan) was used to measure roughness of polished surfaces. In this study, 4 brands of composite resin were examined, Pyrofil bond anterior Bell-Feel anterior Clearfil F II and Microrest A.P. White point, Silicone point, Super snap, and Sof-Lex medium disc as cutting instrument, and celluloid matrix were used. The results obtained were as follows. 1) The celluloid matrix produced the smoothest surfaces. 2) Microrest composite resin had smoother surface than any other composite resins after polishing. 3) The values of surface roughness made by White point, Silicon point and Super snap were similar. 4) The surfaces made by Sof-Lex medium disc was smoother than the surfaces made by any other polishing instruments.

  • PDF

ALTERNATIVE TECHINQUE OF MATRIX BANDING FOR RESTORING OF PROXIMAL CARIOUS LESIONS IN PRIMARY ANTERIOR TEETH (유전치 인접면우식증의 복합레진 충전시 변형된 matrix band의 사용)

  • Ra, Ji-Young;Cho, Hyun;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.453-458
    • /
    • 2003
  • Usually Mylar strip and wedge or celluloid strip crown were used in conventional method of restoring proximal carious lesions of primary anterior teeth. But, these methods have some difficulties to place the matrix and wedge due to short crown lenth and interdental spacing of primary teeth. And it is difficult to form proper cavosurface margin due to the rigidity of matrix and inconvenience to support matrix by practitioner's hand in narrow oral cavity of child. This article describes an alternative technique for restoring carious lesions of primary anterior teeth using available straw. This method is very convenient and reduce chair time and it also allows good marginal adaptation.

  • PDF

FULL COVERAGE RESTORATION OF PRIMARY ANTERIOR TEETH : A CASE REPORT (유전치의 전장피개수복 : 증례보고)

  • Hong, Kee-Sang;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.240-247
    • /
    • 1999
  • Primary anterior teeth requiring extensive restorative therapy due to caries, trauma or developmental defects can present a particularly challenging problem for the pediatric dentist. The ideal restorative technique would combine strength, durability esthetics and efficiency in placement. Couple these concerns with the technical difficulties of operating on children with behavior management problems, and the dentist is left with the difficult task of choosing from a variety of restorative options. Restorative modalities currently in use to treat primary anterior teeth include bonding with composite resin as in celluloid strip crowns, conventional stainless steel crowns, open-faced stainless steel crowns, commercially and chairside veneered stainless steel crowns and epoxy-coated stainless steel crowns. Each of these techniques presents technical, functional or esthetic compromises that complicate their efficient and effective usage. This is a report of the results obtained at the Department of Pediatric Dentistry, College of Dentistry Seoul National University, through the use of these various methods of treating primary anterior teeth.

  • PDF