• 제목/요약/키워드: Cellular Convection

검색결과 13건 처리시간 0.026초

Multi-Cellular Natural Convection in the Melt during Convection- Dominated Melting

  • Kim, Sin;Kim, Min-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제16권1호
    • /
    • pp.94-101
    • /
    • 2002
  • Convection-dominated melting in a rectangular cavity is analyzed numerically with particular attention to the multi-cellular flows in the melt. At the earlier stage of the melting, the melt region is quite similar to a cavity with high aspect rati71, where the multi-cellular natural convection appears. Numerical results show that the formation and evolution of the multiple flow cells in the melt region is approximately similar to t]tat of a single-phase flow in a tall cavity with the same aspect ratio; however, the continuous change of the melt region due to the melting affects the detailed process. Also, numerical aspects for the prediction of the detailed flow structure in the melt are discussed.

직각 밀폐용기내의 복합부력에 의한 자연대류에 관한 실험적 연구 (Experimental Study of Natural Convection Due to Combined Buoyancy in a Rectangular Enclosure)

  • 이진호;현명택
    • 대한기계학회논문집
    • /
    • 제10권2호
    • /
    • pp.247-256
    • /
    • 1986
  • 본 연구에서는 종횡비가 0.2인 직각 밀폐용기내에서 소금물을 시험유체로 하여 양단의 온도 및 농도차가 수평방향으로 가해지는 경우(CASE 1,2) 밀폐용기내 에서의 유동현상과 열전달 특성을 온도 및 농도분포, 흐름의 가시화를 통해 실험적 으로 관찰, 조사하였다

수평 원주형 환형내에서의 정상상태의 공기의 자연대류에 대한 이중해 (Dual Solutions for Steady Natural Convection of Air in Horizontal Cylindrical Annulus)

  • 유주식
    • 대한기계학회논문집B
    • /
    • 제20권9호
    • /
    • pp.2981-2990
    • /
    • 1996
  • Dual solutions for steady natural convection of air between two horizontal concentric cylinders are numerically investigated in the range of $D_i$/TEX>/L(=diameter of inner cylinder/gap width)$\leq$10. It is found that, when the Rayleigh number based on the gap width exceeds a certain critical value, a new flow pattern forming two counter-rotating eddies in the half of the annulus can be realized, which is different from the crescent-shaped flow commonly observed. In the new flow pattern, the fluid near the top of the hot inner cylinder moves downward. This solution is found for D$_{i}$/L.geq.0.3, but not for$D_i$/TEX>/L$\leq$0.2. As $D_i$/TEX>/L increase, the critical Rayleigh number is decreased, and tends to a finite limit.t.

STELLAR MAGNETIC ACTIVITY AND LONG TERM LUMINOSITY VARIATIONS OF LATE TYPE STARS.: I. ON GENERALIZATION OF ${\ddot{O}}PIK'S$ CONVECTION THEORY TO A ROTATING MEDIUM

  • Park, Chang-Bum;Yun, Hong-Sik;Lee, Jeong-Woo
    • 천문학회지
    • /
    • 제18권2호
    • /
    • pp.86-99
    • /
    • 1985
  • A generalization of the original ${\ddot{O}}pik's$ cellular convection theory has been made to accomodate a rotating convective medium. With the use of the formulation, a set of rotating model envelopes of the sun and late type main sequence stars have been constructed under three different rotation periods. Their thermal structures are presented and characteristics of their convection are discussed in the context of stellar dynamo. In the present study it is noted that the rotational angular velocity increases in wards with depth, and its increase turns out to be about 6% at the bottom of the solar convection zone.

  • PDF

다공성 매질에서 Local Thermal Equilibrium에 관한 연구 (Study on Local Thermal Equilibrium in a Porous Medium)

  • 장석필;김성진
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1172-1182
    • /
    • 2002
  • In the present study a general criterion for local thermal equilibrium is presented in terms of parameters of engineering importance which include the Darcy number, the effective Prandtl number of fluid, and the Reynolds number. For this, an order of magnitude analysis is performed for the case when the effect of convection heat transfer is dominant in a porous structure. The criterion proposed in this study is more general than the previous criterion suggested by Carbonell and Whitaker, because the latter is applicable only when conduction is the dominant heat transfer mode in a porous medium while the former can be applied even when convection heat transfer prevails. In order to check the validity of the proposed criterion for local thermal equilibrium, the forced convection phenomena in a porous medium with a microchanneled structure subject to an impinging jet are studied using a similarity transformation. The proposed criterion is also validated with the existing experimental and numerical results for convection heat transfer in various porous materials that include some of the parameters used in the criterion such as a microchannel heat sink with a parallel flow, a packed bed, a cellular ceramic, and a sintered metal. It is shown that the criterion presented in this work well-predicts the validity of the assumption of local thermal equilibrium in a porous medium.

정현적인 온도 분포를 갖는 두 수평 평판 사이에서의 작은 Rayleigh 수 열 대류 (Low Rayleigh Number Thermal Convection Between Two Horizontal Plates with Sinusoidal Temperature Distributions)

  • 유주식;김용진
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.145-152
    • /
    • 2001
  • Low Rayleigh number thermal convection in a fluid layer confined between two-infinite horizontal walls kept at spatially sinusoidal temperature distributions, T_L=T_m+\Delta T\sin \kappax,\;T_U=T_m+\Delta T\sin(\kappax-\beta)$, is theoretically investigated by a regular perturbation expansion method. For small wave numbers, an upright cell is formed between the two walls at $\beta$=0. The cell is tilted, as the phase difference increases, and a flow with tow counter-rotating eddies occurs at $\beta=\pi$. when the wave number is large, isolated eddies are formed near the lower and upper walls, for all the phase differences. There exists a wave number at which maximum heat transfer rate at the walls occurs, at each of the phase differences. And the wave number increases with increase of the phase difference. for a fixed wave number, the heat transfer rate decrease with increase of the phase difference.

  • PDF

일정 열유속 실린더를 갖는 수평 환형 공간에서의 공기의 이중 자연대류 유동 (Dual Natural-Convective Flows of Air in a Horizontal Annulus with a Constant Heat Flux Cylinder)

  • 유주식
    • 한국전산유체공학회지
    • /
    • 제4권2호
    • /
    • pp.1-8
    • /
    • 1999
  • Natural convection in a horizontal annulus with the inner cylinder heated by the application of a constant heat flux and the isothermally cooled outer cylinder is considered, and the transition of flows and the bifurcation phenomenon are numerically investigated for air with Pr=0.7. The zero initial condition always induces a crescent-sheped eddy flow. A bicellular flow in which the fluid descends along the vertical central plane of the annulus can be obtained at high Rayleigh number by introducing artificial numerical disturbances. Dual solutions are found above a certain critical Rayleigh number. Hysteresis phenomena have not been observed.

  • PDF

위상 차이가 있는 작은 파동수의 정현적인 벽면 온도 하에서의 자연 대류 유동의 천이 (Transition of Natural Convective Flows Subjected to Small-Wave-Number Sinusoidal Wall Temperatures with Phase Difference)

  • 유주식
    • 대한공업교육학회지
    • /
    • 제33권2호
    • /
    • pp.300-311
    • /
    • 2008
  • 두 벽면이 서로 다른 평균 온도와 일정한 위상 차이 하에서 작은 파동수의 정현적인 온도 분포를 갖는 시스템에서의 자연 대류를 조사한다. 벽면 온도 분포의 파동수 k=0.5이고 위상차는 ㄱ/2 이며, 고려하는 유체는 Pr =0.7인 공기이다. 작은 Rayleigh 수의 전도 영역에서는 한 주기에 걸쳐 약간 기울어진 형태의 두 개의 큰 셀이 형성된다. 그러나 Rayleigh 수가 증가하면 열적으로 불안정한 영역에서 여러 개의 셀이 형성되는 다수 셀 유동이 일어난다. 다수 셀 영역에서 과도기적인 기간에서는 일시적으로 공간적인 점대칭성이 깨어지기도 하지만 정상 상태의 유동장은 언제나 대칭성을 만족한다. 유동 형태의 천이가 일어나는 임계 Rayleigh 수 부근에서는 Nusselt 수가 급격하게 증가한다.

직사각형 밀폐공간내 자연대류 열전달의 수치해석

  • 민만기
    • 대한설비공학회지:설비저널
    • /
    • 제10권3호
    • /
    • pp.185-219
    • /
    • 1981
  • To analyze two dimensional incompressible laminar natural convection in a rectangular enclosure heated from below and cooled by a horizontal ceiling and two vertical walls, he primitive Navier-Stokes equations and the energy equation were solved numerically in time dependent form by a marker and cell method. A successive over-relaxation method for the elliptic portion of the problem and an explicit method for the parabolic portion were applied for the range of Grashoff number of $5{\times}10^3\;to\;5{\times}10^4$ to get the transient and steady state dimensionless temperature and velocity profiles. For the range of aspect ratio $L/H{\leqq}2.4$ in which only a pair of convection rolls exists mean Nusselt number calculated are as follows : $$N_{NU}0.89\;N_{Gr}^{0.2}(H/L)^{0.45}$$ By path lines drawn by marker particle trajectories roll number of cellular motion were observed for various aspect ratio of the enclosure.

  • PDF

Optimization and Mathematical Modeling of the Transtubular Bioreactor for the Production of Monoclonal Antibodies from a Hybridoma Cell Line

  • Halberstadt, Craig R.;Palsson, Bernhanrd O.;Midgley, A.Rees;Curl, Rane L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권3호
    • /
    • pp.163-170
    • /
    • 2002
  • This report describes the use of a transtubular bioreactor to study the relative effects of diffusion versus perfusion of medium on antibody production by a hybridoma cell line. The study was performed with a high-density cell culture maintained in a serum-free, low-protein medium for 77 days. It was determined that the reactor possessed a macro-mixing pattern residence time distribution similar to a continuous stirred tank reactor (CSTR), However, due to the arrangement of the medium lines in the reactor, the flow patterns for nutrient distribution consist of largely independent medium path lengths ranging from short to long. When operated with cyclic, reversing, transtubular medium flow, some regions of the reactor (with short residence times) are more accessible to medium than others (with long residence times). From this standpoint, the reactor can be divided into three regions: a captive volume, which consists of medium primarily delivered via diffusion; a lapped volume, which provides nutrients through unilateral convection; and a swept volume, which operates through bilateral convection. The relative sizes of these three volumes were modified experimentally by changing the period over which the direction of medium flow was reversed from 15 min (larger captive volume) to 9 h (larger swept volume). The results suggest that antibody concentration increases as the size of the diffusion-limited (captive) volume is increased to a maximum at around 30 min with a sharp decrease thereafter. As reflected by changes in measured consumption of glucose and production of lactate, no significant difference in cellular metabolism occurred as the reactor was moved between these different states. These results indicate that the mode of operation of the transtubular bioreactor may influence antibody productivity under serum-free, low-protein conditions with minimal effects on cellular metabolism.