• 제목/요약/키워드: Cell-in-cell

검색결과 56,591건 처리시간 0.067초

Stem cell maintenance by manipulating signaling pathways: past, current and future

  • Chen, Xi;Ye, Shoudong;Ying, Qi-Long
    • BMB Reports
    • /
    • 제48권12호
    • /
    • pp.668-676
    • /
    • 2015
  • Pluripotent stem cells only exist in a narrow window during early embryonic development, whereas multipotent stem cells are abundant throughout embryonic development and are retainedin various adult tissues and organs. While pluripotent stem cell lines have been established from several species, including mouse, rat, and human, it is still challenging to establish stable multipotent stem cell lines from embryonic or adult tissues. Based on current knowledge, we anticipate that by manipulating extrinsic and intrinsic signaling pathways, most if not all types of stem cells can be maintained in a long-term culture. In this article, we summarize current culture conditions established for the long-term maintenance of authentic pluripotent and multipotent stem cells and the signaling pathways involved. We also discuss the general principles of stem cell maintenance and propose several strategies on the establishment of novel stem cell lines through manipulation of signaling pathways.

Effect of Ferulic Acid on Cell Viability and Cell Adhesion Activity in Normal Human Gingival Fibroblasts

  • Lee Joo-Hyun;Jin Byung-Jo;Son Il-Hong;Han Du-Seok
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.269-273
    • /
    • 2004
  • This study was designed to investigate the effect of ferulic acid on cell viability and cell adhesion activity in normal human gingival fibroblasts. The cell viability and cell adhesion activity of ferulic acid was measured by MTT assay or XTT assay, respectively, after normal human gingival fibroblasts were treated with or without ferulic acid for 48 hours. The cell viability of ferolic acid on normal human gingival fibroblasts did not show any decreasement by MTT assay and also, cell adhesion activity did not decreased by XTT assay, respectively, compared with control after cells were treated with various concentrations of ferolic acid for 48 hours. MTT/sub 50/ and XTT/sub 50/ were 2,130.0 μM and 1,773.7 μM ferolic acid, respectively. These results suggest that ferolic acid is non-toxic to normal human gingival fibroblasts by showing no significant differences in the cell viability and the adhesion activity compared with control by colorimetric assay.

  • PDF

잡음에 강인한 셀 아이디 검출 및 SNR 추정 알고리즘 (Cell ID Detection and SNR Estimation Algorithms Robust to Noise)

  • 이종현;배진호
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.139-145
    • /
    • 2010
  • 본 논문에서는 이동 기지국 채널 환경에 적용될 수 있는 이동 기지국 Cell ID 검출 및 신호대잡음비 추정 알고리즘을 제안한다. 제안된 Cell ID 추정 알고리즘은, 부공간(Subspace)을 이용하여 이동 셀 내에서 사용 중인 Cell ID를 추정하는 알고리즘이다. 제안된 이동기지국 SNR 추정 알고리즘은 고유값과 잡음 부공간 수를 이용하여 SNR을 추정하는 알고리즘이다. 모의실험을 통하여 기존의 상관계수를 이용한 방법들과 제안된 알고리즘들을 비교한 결과 Cell ID 검출 및 신호대잡음비 추정 성능이 매우 우수함이 입증하였고, 배경 잡음 및 간섭 신호로 인한 열악한 고속 채널환경에서 제안된 알고리즘이 적합함을 보였다.

시뮬레이션 기반 연료전지/2차전지 하이브리드 미니버스의 설계 및 성능 평가 (Design and Performance Evaluation for a Fuel Cell/Battery Hybrid Mini-Bus Based on a Simulation)

  • 김민진;공낙원;이원용;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제18권1호
    • /
    • pp.60-66
    • /
    • 2007
  • In terms of the vehicle efficiency, a fuel cell hybrid system has advantages compared to a conventional internal combustion engine and a fuel cell alone-powered system. The efficiency of the fuel cell hybrid vehicle mainly depends on the maximum power of the fuel cell and therefore it is important to decide the design value of the fuel cell maximum power. In this paper, to estimate the performance of the fuel cell hybrid mini-bus in the design phase the simulator based on the models for the fuel cell stack, the electric battery, the fuel cell balance of plant, the controller, and the vehicle itself is proposed. Additionally, the hybrid mini-bus efficiencies with several different fuel cell powers are simulated for a city driving schedule and are compared on another. Consequently, the proposed simulation scheme is useful to determine the best design value of the fuel cell hybrid vehicles.

Microfabricated Cell Chip for Cell-based in vitro Assay

  • 박제균;김태한;이상은;김수현;윤규식;이정건
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.115-118
    • /
    • 2000
  • 미세 가공 기술을 이용하여 제작된 IDA 전극을 활용하여 임피던스 측정방식의 cell chip으로의 응용에 대해 고찰하였다. IDA 전극은 기존의 반도체 공정으로서 손쉽게 제작할 수 있고, 대량 제작시 전극의 재현성 확보가 용이하고 소형화 할 수 있으며 낮은 단가로 제작될 수 있는 장점이 있다. IDA 전극을 채용한 cell chip을 B16-F1 melanoma 세포 배양에 적용한 결과, 세포성장과 임피던스 변화량이 상관성을 보였고, 세포의 성장을 저해하는 약물의 투과시 cell chip의 임피던스 변화 역시 기존의 방법과 유사한 결과를 보여 주었다.

  • PDF

한우 섬유아세포의 성 판별 및 세포주기 유도 분석 (Sexing and Cell Cycle Induction Hanwoo Fetal Fibroblast Cells)

  • 김현주;강회성;최화식;이성호;박창식;진동일
    • 한국가축번식학회지
    • /
    • 제27권1호
    • /
    • pp.53-59
    • /
    • 2003
  • 본 연구에서는 한우 태아의 시기별로 35일령, 50일령, 70일령 및 90일령의 fetal fibroblast cell line을 생산하였고, bovine-specific primer와 Y chromosome-specific primer를 이용하여 PCR에 의해 성을 판별하여 각각 암수 2 line의 한우 fetal fibroblast cell line을 확립하였다. 이들 cell line을 계대배양하여 passage number가 10 이상에서 염색체 분석을 실시하였는데 모두에서 80%이상의 세포가 60개의 정상 염색체수의 나타내어 계대배양이 karyotype에 영향을 미치지 않는 것으로 나타났다. Serum starvation과 confluent 배양 방법을 이용하여 Go 상태로 유도되었는지 확인하기 위해 PCNA antibody를 이용하여 Western blotting 분석을 실시하였는데 PCNA 발현이 현저히 감소되는 것을 확인할 수 있었고, 다시 정상 medium으로 환원시켰을 때 세포분열이 재개되어 Go상태로 유도되었음을 확인할 수 있었다. 또한 serum stravation 방법이 conflent한 배양방법보다 PCNA 발현양이 적은 것으로 나타나 좀더 효율적인 Go 상태 세포 주기 조절방법으로 판명되었다.

Bifidobacteria의 Caco-2 Cell 정착성에 미치는 영향 인자 (Factors Affecting the Adherence of Bifidobacteria to Caco-2 Cell)

  • 김응률;정후길;전석락;유제현
    • 한국축산식품학회지
    • /
    • 제21권2호
    • /
    • pp.133-141
    • /
    • 2001
  • Adherence of probiotic bacteria to intestinal epithelium is found to be the most principal characteristics among the various physiological functionality. This study was conducted to investigate the effect of bifidobacterial growth properties and condition on the Caco-2 cell adherence and to construct a basic data on adherence-related research. Among 20 strains of bifidobacteris tested, when measured by cell surface hydrophobicity(CSH) and cell agglutination(CA), Bifidobacterium bifidum ATCC29521, Bif. adolescentis K8, and Bif. infantis K9 were selected. Using these strains, variations of Caso-2 cell adherence depending upon experimental condition were analyzed. The results obtained are as follows : Even though Bif. bifidum ATCC29521, Bif. adolescentis K8, and Bif. infantis K9 reached more 85% cell surface hydrophobicity there was no significant difference in cell agglutination, when reached 31.54$\pm$0.54mg/ml. By direct count method for adherence, viable cell count of M3, K1, K2, K8, K9 and K10 reached more 100 counts per 100 Caco-2 cells. When Bif. bifidum ATCC29521, Bif. adolescentistis K8, and Bif. infantis K9 were used to compare the adherence depending upon viable cell counts, reaction time, and growth phase, the more viable cell count, and the more adhered cell counts, the less adherence percentage. In addition, there was no difference in adherence percentage of bifidobacteria when bifidobacteria was incubated from 1 to 8 hrs after Caco-2 cells already formed monolayer. Considering of the effect of growth phase of bifidobacteria on adherence variation, all strains showed the highest adherence during the early stage of stationary phase. In conclusion, adherence of bifidobacteria was affected by strain specificity, viable cell count, and growth activity.

  • PDF

Passaging Method for Expansion of Undifferentiated Human Embryonic Stem Cells by Pipetting Technique

  • Lee, Sung-Geum;Moon, Sung-Hwan;Lee, Soo-Hong;Lee, Hey-Jin;Kim, Jae-Hwan;Chung, Hyung-Min
    • Reproductive and Developmental Biology
    • /
    • 제30권4호
    • /
    • pp.287-291
    • /
    • 2006
  • We have developed a new passaging technique for the expansion of human embryonic stem cells (hESCs) that involves simply pipetting portions of hESCs acquired from colonies, reducing the laborious and time-consuming steps in the expansion of hESCs. Compared to general mechanical methods of passaging, our pipetting method allowed hESCs colonies to be broken into small fragments, which showed significantly higher attachment rates onto feeder cell layers. This technique produced three times the number of hESCs colonies than conventional mechanical methods. In addition, this pipetting method allowed us to distinguish differentiated hESCs from undifferentiated hESCs during hESCs colony pipetting. The hESCs cultured by pipetting method displayed normal human chromosomes for over 60 passages. According to RT-PCR and immunohistochemical analysis, the hESCs successfully maintained their undifferentiated state and pluripotency which was also confirmed by teratoma formation in viva Therefore, the pipetting method described in this study is a useful tool to efficiently and quickly expand hESCs on a large scale without enzyme treatment.

동적 우선순위 제어방식을 사용한 ATM 스위치의 성능분석 (Performance Analysis of ATM Switch Using Dynamic Priority Control Mechanisms)

  • 박원기
    • 한국통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.855-869
    • /
    • 1997
  • In this paper, we proposed two kids of dynamic priority control mechanisms controlling the cell service ratio in order to improve the QOS(Quality of Service). We also analyse theoretically the characteristics of cell loss probability and mean cell delay time by applying the proposed priority control mechanisms to ATM switch with output buffer. The proposed priority control mechanisms have the same principles of storing cells into buffer but the different principles of serving cells from buffer. The one is the control mechanism controlling the cell service ratio according to the relative cell occupancy ratio of buffer, the other is the control mechanism controlling the cell service ratio according to both the relative cell occupancy ratio of buffer and the average arrival rate. The two service classes of our concern are the delay sensitive class and the loss sensitive class. The analytical results show that the proposed control mechanisms are able to improve the QOS, the characteristics of cell loss probability and mean cell delay time, by selecting properly the relative cell occupancy ratio of buffer and the average arrival rate. conventional DLB algorithm does not support synchronous cells, but the proposed algorithm gives higher priority to synchronous cells. To reduce synchronous cell loss rate, the synchronous cell detector is used in the proposed algorithm. Synchronous cell detector detects synchronous cells, and passes them cells to the 2nd Leaky-Bucket. So it is similar to give higher priority to synchronous cells. In this paper, the proposed algorithm used audio/video traffic modeled by On/Off and Two-state MMPP, and simulated by SLAM II package. As simulation results, the proposed algorithm gets lower synchronous cell loss rate than the conventional DLB algorithms. The improved DLB algorithm for multimedia synchronization can be extended to any other cells which require higher priority.

  • PDF

A study of Polarization Modulator to Single-cell type in Polarized Glasses 3D Display System Using Binocular Parallax

  • Kong, Kyung-Bae;Kwon, Jung-Jang
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.71-78
    • /
    • 2019
  • 현재 상용화된 대부분의 3D 디스플레이는 왼쪽 눈과 오른쪽 눈의 입력영상을 다르게 만들어 입체감을 만드는 양안시차 방식을 적용하고 있다. 하지만 상용화된 3D 영상 출력 장치는 성능 부족에 의한 시청자의 불편 유발과 시청위치의 제약 등의 문제들이 있다. 본 논문에서는 기존 Dual-cell 구조 대비 시야각, Crosstalk 감소, 광투과도를 향상할 수 있는 Single-cell 구조의 편광안경식 입체영상 시스템을 개발하고, 투과도 실험과 시야각 평가를 통해 Single-cell 구조의 편광안경식 입체영상 시스템 특성분석과 Dual-cell 구조 대비 성능향상 효과 분석을 진행하였다. 분석 결과 Single-cell 구조가 Dual-cell 구조 대비 투과도 부분에서 약 25% 이상의 높은 성능을 보이며, 시야각 평가 중 입체 영상 특성품질의 주요지표인 3D crosstalk 지표는 약 37% 이상 향상되는 것을 확인할 수 있었다.