• Title/Summary/Keyword: Cell to module loss

Search Result 59, Processing Time 0.021 seconds

Correlation between Reverse Voltage Characteristics and Bypass Diode Operation with Different Shading Conditions for c-Si Photovoltaic Module Package

  • Lim, Jong-Rok;Min, YongKi;Jung, Tae-Hee;Ahn, Jae-Hyun;Ahn, Hyung-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.577-584
    • /
    • 2015
  • A photovoltaic (PV) system generates electricity by installing a solar energy array; therefore, the photovoltaic system can be easily exposed to external factors, which include environmental factors such as temperature, humidity, and radiation. These factors-as well as shading, in particular-lead to power degradation. When there is an output loss in the solar cell of a PV module package, the output loss is partly controlled by the bypass diode. As solar cells become highly efficient, the characteristics of series resistance and parallel resistance improve, and the characteristics of reverse voltage change. A bypass diode is connected in parallel to the string that is connected in series to the PV module. Ideally, the bypass diode operates when the voltage is -0.6[V] around. This study examines the bypass diode operating time for different types of crystalline solar cells. It compares the reverse voltage characteristics between the single solar cell and polycrystalline solar cell. Special modules were produced for the experiment. The shading rate of the solar cell in the specially made solar energy module was raised by 5% each time to confirm that the bypass diode was operating. The operation of the bypass diode is affected not only by the reverse voltage but also by the forward bias. This tendency was verified as the number of strings increased.

Effect of Laser Scribing in High Efficiency Crystal Photovoltaic Cells to Produce Shingled Photovoltaic Module (슁글드 모듈 제작을 위한 고효율 실리콘 태양전지의 레이저 스크라이빙에 의한 영향)

  • Lee, Seong Eun;Park, Ji Su;Oh, Won Je;Lee, Jae Hyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.291-296
    • /
    • 2020
  • The high power of a shingled photovoltaic module can be attributed to its low cell-to-module loss. The production of high power modules in limited area requires high efficiency solar cells. Shingled photovoltaic modules can be made by divided solar cells, which can be produced by the laser scribing process. After dividing the 21% PERC cell using laser scribing, the efficiency decreased by approximately 0.35%. However, there was no change in the efficiency of the solar cell having relatively lower efficiency, because the laser scribing process induce higher heat damages in solar cells with high efficiency. To prove this phenomena, the J0 (leakage current density) of each cell was analyzed. It was found that the J0 of 21% PERC increased about 17 times between full and divided solar cell. However, the J0 of 20.2% PERC increased only about 2.5 times between full and divided solar cell.

PV Module Configuration Considering Environment Conditions of Photovoltaic System (태양광 발전시스템의 환경조건을 고려한 PV 모듈 구성)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.31-41
    • /
    • 2014
  • This paper proposes the configuration of photovoltaic(PV) module considering the environment conditions of the PV system. The PV system is consisted of the series-parallel connection of the PV module. When shadows or changes of the radiation or an electrical characteristic in the solar cell are happened to PV system, the serious power loss will occur. If the PV module connected in series has the shadows, the output current is restricted to current of shaded PV module. Also if shadow is occurred to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, this paper proposes the method that makes the output power of the PV module equalize by reconfiguration of PV module using the switching considering these environment conditions. A validity of the method proposed in this paper proves through comparing with performance of conventional PV module.

텍스쳐 형성 방식에 따른 실리콘 태양전지의 모듈화에 의한 효율 손실에 대한 연구

  • No, Jun-Hyeong;Son, Chan-Hui;Kim, Dong-Hae;Seo, Il-Won;Yun, Myeong-Su;Jo, Tae-Hun;Jo, Lee-Hyeon;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.438-438
    • /
    • 2012
  • 결정질 실리콘 태양전지 공정 중 텍스쳐 공정은 표면에서 반사되는 반사광을 줄여 단락전류(Isc)를 증가시킨다. 표면 텍스쳐 형성 방식으로는 일반적으로 습식 식각(Wet etching) 공정과 건식 식각(Reactive ion etching:RIE) 공정이 있다. 습식 식각 공정은 식각 용액을 사용하는 공정이며 건식 식각 공정은 플라즈마를 통하여 식각하는 공정으로 습식 식각 공정의 경우 식각 용액에 의한 공정상 위험도가 높으며, 용액의 폐기물에 의한 환경오염 문제가 크다. 건식 식각공정의 경우 습식 식각과 달리 공정상 위험도가 낮으며 불규칙적인 결정방향에 영향 받지 않는 비등방성 식각이 가능하여 다결정 실리콘 태양전지의 경우 습식 식각 공정보다 반사광이 적어 단락전류가 증가하게 된다. 그리고 태양전지를 Photovoltaic module로 만들게 되면 태양전지의 효율이 떨어지는데 이것을 Cell to module loss (CTM loss)라 부르며 이는 태양전지의 발전량을 줄이는 큰 원인이 된다. CTM loss의 경우 습식 식각 공정보다 건식 식각 공정에서 더 크게 나타나며 건식 식각 공정한 PV module의 경우 CTM loss로 인해 습식 식각 공정을 통한PV module와 비슷한 효율을 내게 된다. 본 연구에서는 식각 공정의 방식에 따라 나타나는CTM loss 중 광 손실 원인을 외부양자효율(External Quantum Efficiency)과 투과율(Transmittance), 반사율(Reflectance) 등 광 특성 통하여 분석한다.

  • PDF

The Analysis of the Current Loss in the Parallel Connection of Dye-sensitized Solar Cells (염료감응형 태양전지의 병렬 연결에서 발생하는 전류 손실 분석)

  • Seo, Hyun-Woong;Lee, Kyoung-Jun;Son, Min-Kyu;Hong, Ji-Tae;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.412-415
    • /
    • 2008
  • In a research on the practical dye-sensitized solar cell, a study on a large module have preference because module must be able to generate the proper current that is possible to convert electrically. So the parallel connection of dye-sensitized solar cells which outputs a large current easily is essential. However, there is a current loss in a paralle connection of dye-sensitized solar cells and the loss becomes larger according to increasing the number of parallel connection. In this study, we analyzed the cause of the current loss in the parallel connection by using the equivalent circuit analysis. One DSC used in this experiment had an active area $8cm^2$(4.62cm$\times$1.73cm) and it attained a conversion efficiency of 5.43% under 1 sun illumination ($P_{in}$ of 100 mW/$cm^2$) using a solar simulator.

  • PDF

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

Analysis of Power Variation and Design Optimization of a-Si PV Modules Considering Shading Effect (음영효과를 고려한 a-Si PV모듈의 출력 변화 및 최적 설계조건에 관한 연구)

  • Shin, Jun-Oh;Jung, Tae-Hee;Kim, Tae-Bum;Kang, Ki-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.102-107
    • /
    • 2010
  • a-Si solar cell has relatively dominant drift current when compared with crystalline solar cell due to the high internal electric field. Such drift current make an impact on the PV module in the local shading. In this paper, the a-Si PV module output characteristics of shading effects was approached in terms of process condition, because of the different deposition layer of thin film lead to rising the resistance. We suggested design condition to ensure the long-term durability of the module with regard to the degradation factors such as hot spot by analyzing the module specification. The result shows a remarkable difference on module uniformity for each shading position. In addition, the unbalanced power loss due to power mismatch of each module could intensify the degradation.

Operation Characteristics of Bypass Diode for PV Module (태양전지 모듈의 바이패스 다이오드 동작 특성 분석)

  • Kim, Seung-Tae;Park, Chi-Hong;Kang, Gi-Hwan;Lawrence, Waithiru C.K.;Ahn, Hyung-Keun;Yu, Gwon-Jong;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • In this paper, an I-V characteristics of bypass diode has been studied by counting the shading effect in photovoltaic module. The shadow induces hot spot phenomenon in PV module due to the increase of resistance in the current path. Two different types of PV module with and without bypass diode were fabricated to expect maximum output power with an increasing shading rate of 5 % on the solar cell. Temperature distribution is also detected by shading the whole solar cell for the outdoor test. From the result, the bypass diode works properly over 60 % of shading per cell with constant output power. Maximum power generation in case of solar cell being totally shaded with bypass diode decreases 41.3 % compared with the one under STC(Standard Test Condition). On the other hand, the maximum output power of the module without bypass diode gradually decreases by showing hot spot phenomenon with the increase of shading ratio on the cell and finally indicates 95.5 % of power loss compared with the output under STC. Finally the module temperature measured increases around $10^{\circ}C$ higher than that under STC due to hot-spots which come from the condition without bypass diode. It has been therefore one of the main reasons for degrading the PV module and shortening the durability of the PV system.

Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes (PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석)

  • Shin, Woo-Gyun;Jung, Tae-Hee;Go, Seok-Hwan;Ju, Young-Chul;Chang, Hyo-Sik;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.67-75
    • /
    • 2015
  • PV module is conventionally connected in series with some solar cell to adjust the output of module. Some bypass diodes in module are installed to prevent module from hot spot and mismatch power loss. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we study the thermal and electrical characteristics change of module with damaged bypass diode to easily find module with damaged bypass diode in photovoltaic system consisting of many modules. Firstly, the temperature change of bypass diode is measured according to forward and reverse bias current flowing through bypass diode. The maximum surface temperature of damaged bypass diode applied reverse bias is higher than that of normal bypass diode despite flowing equal current. Also, the output change of module with and without damaged bypass diode is observed. The output of module with damaged bypass diode is proportionally reduced by the total number of connected solar cells per one bypass diode. Lastly, the distribution temperature of module with damaged bypass diode is confirmed by IR camera. Temperature of all solar cells connected with damaged bypass diode rises and even hot spot of some solar cells is observed. We confirm that damaged bypass diodes in module lead to power drop of module, temperature rise of module and temperature rise of bypass diode. Those results are used to find module with a damaged bypass diode in system.

Performance analysis of the B-NT system using simulstor (시뮬레이터를 이용한 B-NT 시스템 성능분석)

  • 이규호;기장근;노승환;최진규;김재근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1503-1513
    • /
    • 1998
  • This paper is related to a performance analysis of B-NT system, which is essential compositional equipment of B-ISDN access network. A simulator enabling performance analysis according to the change of network configuration topology and the change of user traffic is developed in this study. The developed B-NT, system simulator consists of graphic user interface module, simulation program automatic generator module, and B-NT system model library module. As examples of the results of performance analysis using the simulator, end-to-end user cell transmission delay time, queueing delay time in each system, and cell loss rate in the head node switch are presented. The simulator developed in this paper can be utilized in determining the network topology of B-NT system.

  • PDF