• 제목/요약/키워드: Cell stack

검색결과 583건 처리시간 0.029초

TiN이 코팅된 316 스테인리스강 분리판을 이용한 1 kW 급 고분자전해질 연료전지 스택의 운전특성 (Performance of a 1 kW PEMFC Stack Using the TiN-Coated 316 Stainless Steel Bipolar Piates)

  • 전의식;조은애;하흥용;홍성안;오인환
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.39-45
    • /
    • 2004
  • A 12-cell PEMFC stack was fabricated using the TiN-coated 316 stainless steel bipolar plates as substitute for the expensive and brittle graphite bipolar plates. Open cirtuit voltage and the maximum power of the stack was 12.08 V and 1.197 kW (199.5 A @ 6 V), respectively. Volumetric and gravimetric power density of the stack was calculated to be 373 W/L and 168 W/kg, respectively. Performance of each cell was quite uniform initially while degraded at a singnificantly different rate. During the 1,000 hr-operation at a constant load of 48 A, stack voltage decreased from 9.0 to 7.98 V at a degradation rate of 11 %/1,000 hr. However, degradation rate of each cell was in the wide rage from 1.2 to 31 %/1,000 hr.

인산형 연료전지 30W급 스택제조 및 발전실험 (Fabrication of 30W PAFC stack and its electrical performance)

  • 김창수;송락현;최병우;한성옥;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.78-80
    • /
    • 1991
  • Preliminary multiple cell stack testing was performed using three-cell stack each electrode having an active area of $100cm^2$. The stack was operated at $190^{\circ}C$, the output power was 32W at 1.8V and maximum power was 69W. It was recorded as the first stack fabricated in Korea and continuous research works on the fabrication of stack, optimization of stack performance and long run tests will be conducted.

  • PDF

용융탄산염형 연료전지의 스택구조와 온도특성 (Temperature Characteristics of the Molten Carbonate Fuel Cell Stack)

  • 이충곤;안교상;박성연;서혜경;임희천
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.54-61
    • /
    • 2004
  • Temperature characteristics in a stack of molten carbonate fuel cell (MCFC) have been investigated with simulation based on the computational fluid dynamics (CFD) codes and experimental way. The MCFC has generally two stack structures when the natural gas is used as fuel; one is the external reforming type and the other is internal reforming type. Computer simulation at the external reforming stack suggests that the maximum temperature in the stack depends on the gas flow length. The 2 kW MCFC stack with 25 cm gas flow length showed about $675^\circ{C}$ of maximum temperature.

직접 메탄올 연료 전지의 성능에 대한 메탄올 농도, 풍속 및 스택 온도의 영향 (Effects of the Methanol Concentration, Wind Velocity and Stack Temperature on the performance of Direct Methanol Fuel Cell)

  • 김용하;김석일
    • 항공우주시스템공학회지
    • /
    • 제1권2호
    • /
    • pp.21-26
    • /
    • 2007
  • DMFC(Direct Methanol Fuel Cell) has been considered as an attractive option to produce electric power in many application. In this study, in order to estimate the effects of the methanol concentration, wind velocity and temperature on the performance of DMFC, a physical prototype of DMFC was designed and manufactured, and the stack voltage of DMFC was measured during the operation of DMFC. Expecially, the experimental results showed that a low stack temperature, a low wind velocity and an excess methanol concentration lead to the increase of the time to reach the maximum stack voltage.

  • PDF

100 kW급 용융탄산염 연료전지 스택 및 발전 시스템 설계 (Design of a 100 kW MCFC Stack and Power Generation System)

  • 고준호;강병삼;임희천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.146-151
    • /
    • 2001
  • Several design parameters for a 100 kW molten carbonate fuel cell stack was described. Approximately 170 cells are required to generate 100 kW at a current density of $125\;mA/cm^{2}$ with $6000\;cm^{2}$ cells. An overall heat balance was calculated to predict exit temperature. In order to limit the stack temperature in the range of $600-700^{\circ}C$, current load cannot exceed $75\;mA/cm^{2}$ at atmospheric operation. The 100 kW power is expected only under pressurization. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^{2}$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition.

  • PDF

재생전원 시스템의 지상 시뮬레이터용 1kW급 재생형 연료전지 개발 (Development of the 1kW Class Regenerative Fuel Cell for Ground Simulator of Regeneration Electric Power System)

  • 김형모;양철남;홍병선;박영일
    • 대한기계학회논문집B
    • /
    • 제30권11호
    • /
    • pp.1117-1122
    • /
    • 2006
  • The PEM type regenerative fuel cell(RFC) for the ground simulator of the regeneration electric power system has been designed, manufactured, and tested. In this paper, the designing and manufacturing procedures of the RFC were presented. Also, the performance test results were showed briefly. The RFC consists of PEM type stack, humidifier, pressure and flow control valve, storage tanks, pump and controller. The performance tests were carried out with stack and system performance tests. The performance targets are more than 50% stack efficiency, 1.5kW stack power, less 400W parasitic power in design condition. Most of the performances required are satisfied.

자동차 연료전지 진단 및 백금 촉매제 최소화에 대한 연구 (Methods for Diagnosis and Minimum PT-Loading of PEM Fuel Cell Stack)

  • 유승열;이용현
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.105-108
    • /
    • 2013
  • To resolve global environmental problems, many automobile companies are making a great deal of effort to develop so-called green-cars. One of the solutions is an electric vehicle equipped with the PEMFC (Proton Exchange Membrane Fuel Cell) stack. However, the cost of the stack, at the moment, is still too high. This obstacle must be resolved for commercialized fuel cell cars. One of the reasons for high cost is a relatively large amount of Pt (platinum) in the membrane. In this paper, a method for reducing the Pt-loading is introduced. Furthermore, the durability of the stack will be important for a company to stay competitive in world markets (in the future). For this, the diagnosis of the stack must be conducted on-line. Some diagnosis methods as key technology are also introduced in this paper.

교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가 (Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack)

  • 임희천;설진호;류철성;이창우;홍성안
    • 한국수소및신에너지학회논문집
    • /
    • 제6권2호
    • /
    • pp.53-63
    • /
    • 1995
  • 차세대의 새로운 발전방식인 용융탄산염형 연료전지 시스템개발 사업중 실용 스택개발을 위하여 전극유효연적이 $100cm^2$ 인 단위전지를 10단 적층한 Cross Flow형 MCFC스택을 제작하고 2성능측정설비를 구성하여 장기운전시험을 실시하였다 연료로는 $H_2/CO_2/H_2O$의 비율을 72%/18%/10% 로 조성한 가스를 이용하고 산화제가스로는 $O_2/CO_2$$Air/CO_2$ 비율이 33%/67%, 70%/30%가 되는 가스를 이용하여 운전할때의 초기성능 및 15A($150mA/cm^2$) 정부하 상태에서의 장기운전시험시의 전압 강하율을 조사하였다. 운전시간 310시간이 경과된 후의 스택전압은 8.39V이었고 이때의 출력은 125.8W를 보여주었다. 한편 1845시간이 경과한후 공기를 산화제로 이용하는 경우 전압은 6.95V로서 출력 104W를 나타내고 있다. 초기성능치에 의한 에너지 변환효율은 이용율이 40%인 경우 29.65%이었고 80%로 증가하는 경우 약 51.5%가 된다. 1840시간의 경과한때 까지의 전압 강하율은 약 52.4mV/1000hr로서 이전의 스택보다는 전압강하율이 감소되고 있으며 스택의 성능 저하의 주요한 요인은 개회로 전압의 저하로 내부단락동에서 기인하는 것으로 여겨진다. 또한 장기운전사 스택내부에서의 단위전지 전압분포가 균일하지 않음을 알 수 있어 이에 대한 개선을 필요로 한다.

  • PDF

원통형 고체산화물 연료전지 스택 제작 및 성능평가 (Fabrication and Performance Evaluation of Tubular Solid Oxide Fuel Cells Stack)

  • 김완제;이승복;송락현;박석주;임탁형;이종원
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.467-471
    • /
    • 2013
  • In present work, optimized the manufacturing process of anode-supported tubular SOFCs cell and stack were studied. For this purpose, we first developed a high performance tubular SOFC cell, and then made electrical connection in series to get high voltage. The gas sealing was established by attaching single cells to alumina jig with ceramic bond. Through these process, we can obtain such high OVP as around 15V, which means that the electrical connection and gas sealing were optimized. Finally we developed a new tubular SOFC stack which shows a maximum power of 65W @ $800^{\circ}C$.

인산형 연료전지 스택의 전산모사 (Simulation Study of the Phosphoric Acid Fuel Cell Stack)

  • 최성우;이갑수;김화용
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.243-250
    • /
    • 2001
  • 연료전지는 환경 친화적 대체에너지로 지속적인 연구가 이루어지고 있다. 최근에는 연료전지의 실용화를 위해 적층, 대면적화에 대한 기본 기술이 중요시되고 있다. 그러나 연료전지중 가장 많은 기술적 발전을 이룬 인산형 연료전지에 관해서도 연료전지 설계의 기초자료가 되는 스택의 온도 분포에 대한 연구는 거의 발표되지 않았다. 본 연구에서는 인산형 연료전지 스택의 온도 분포를 전산모사하였다. 이를 통하여 여러 작동 조건에서 스택의 온도 분포를 알아내었으며, 스택 운전시 적절한 온도 측정 위치를 예측할 수 있었다. 또한 냉각단의 유로를 변경하여 전산모사를 수행한 결과 스택 내부의 온도 분포의 표준 편차를 약 50% 감소시키는 효과적인 냉각 디자인을 제안할 수 있었다.

  • PDF