Design of a 100 kW MCFC Stack and Power Generation System

100 kW급 용융탄산염 연료전지 스택 및 발전 시스템 설계

  • 고준호 (한전 전력연구원 발전연구실, 연소신발전그룹) ;
  • 강병삼 (한전 전력연구원 발전연구실, 연소신발전그룹) ;
  • 임희천 (한전 전력연구원 발전연구실, 연소신발전그룹)
  • Published : 2001.06.27

Abstract

Several design parameters for a 100 kW molten carbonate fuel cell stack was described. Approximately 170 cells are required to generate 100 kW at a current density of $125\;mA/cm^{2}$ with $6000\;cm^{2}$ cells. An overall heat balance was calculated to predict exit temperature. In order to limit the stack temperature in the range of $600-700^{\circ}C$, current load cannot exceed $75\;mA/cm^{2}$ at atmospheric operation. The 100 kW power is expected only under pressurization. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^{2}$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition.

Keywords