• Title/Summary/Keyword: Cell interconnection

Search Result 83, Processing Time 0.026 seconds

Maximum Terminal Interconnection by a Given Length using Rectilinear Edge

  • Kim, Minkwon;Kim, Yeonsoo;Kim, Hanna;Hwang, Byungyeon
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.114-119
    • /
    • 2021
  • This paper proposes a method to find an optimal T' with the most terminal of the subset of T' trees that can be connected by a given length by improving a memetic genetic algorithm within several constraints, when the set of terminal T is given to the Euclidean plane R2. Constraint (1) is that a given length cannot connect all terminals of T, and (2) considers only the rectilinear layout of the edge connecting each terminal. The construction of interconnections has been used in various design-related areas, from network to architecture. Among these areas, there are cases where only the rectilinear layout is considered, such as wiring paths in the computer network and VLSI design, network design, and circuit connection length estimation in standard cell deployment. Therefore, the heuristics proposed in this paper are expected to provide various cost savings in the rectilinear layout.

The channel coding algorithm for the ATM cell QoS improvement in statellite B-ISDN/ATM network (위성 B-ISDN/ATM 망에서 ATM 셀 전송성능 개선을 위한 채널코딩 알고리즘)

  • 김신재;김병균;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.1083-1096
    • /
    • 1997
  • To implement satellite B-ISDN/ATM network, it needs to gurantee reliable transport via satelite in the poor BER environment. So, it requires to use channel coding (FEC:Forward Error Correction) schemes for improvement of BER performance, but these coding effects evoke burst errors and degradation of the QoS. Therefore we have to investigate new algorithm that compensates these weaknesses. We consider convolutional coding and concatenated coding among FEC schemes as FEC for satellite transmission and choose different compensational algorithm by the error characteristics of the using type of FEC. In using concatenated coding, this paper proposes the satellite system structure for interconnection to the terrestrial network and proposes the channel coding algorithm for improvement of transmission performances. We execute performance evaluation of the proposed algorithm by computer simulation. In detail, we propose 4 types of application ATM cell to the block coding(Reed-Solomon) and propose the new 55 byte ATM cell that enforces the error correction capability of cell header by the BCH coding. Then we propose the outer interleaverand the cell unit interleaver that evoke maximum coding effect of BCH code.

  • PDF

Open Manufacturing System Using MMS Service and Object Oriented Manufacturing Devices(2nd Report) (생산장비 객체화의 개방형 가공 셀 구축 연구(II) -개방형 가공 셀 구축-)

  • Kim, Seon-Ho;Kim, Dong-Hun;Park, Gyeong-Taek
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.41-48
    • /
    • 2000
  • Manufacturing devices must be integrated for constructing CIM environment, but integration of heterogeneous system meets several economical and technological difficulties. In this case, MMS(Manufacturing Message Specification) can be an effective method, but it has problems which MMS products are generally very expensive and majority of the existing manufacturing devices do not support MMS. This paper describes the development of a gateway for Non-MMS-Compatible CNC machine tools to serve MMS and the implementation of OSI(Open System Interconnection) upper layer on TCP/IP. The developed system is applied to construct cell controller with heterogeneous devices under CIM environment and to evaluate interoperability and portability.

  • PDF

The Performance of Banyan Type ATM Switch using Monotonic Buffering Scheme (단조 버퍼링 방식을 이용한 Banyan형 ATM 스위치의 성능평가)

  • 김범식;우찬일;신인철
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1997.11a
    • /
    • pp.147-161
    • /
    • 1997
  • In the future, the performance of B-lSDN offering the multimedia and a various service depends on the performance of switch that is the important factor consisting of network. Bufferless banyan network consisted of MIN(multistage interconnection network) selected for- the fabric of ATM switch and has a limitation of performance because of blocking. Input buffered banyan networks with FIFO(first-in first-out) buffering scheme for the reduction of blocking and the cell bypass queueing theory for the reduction of HOL(head of line) blocking were seperately compared of the performance of switch. Specially input buffered banyan networks were applied monotonic buffering scheme that was proposed. As a result of simulation, Buffered Banyan Network with cell bypass queueing theory showed better performance than FIFO type input buffered Banyan network. Monotonic increase buffering scheme showed better performance than Monotonic decrease buffering scheme.

  • PDF

A Study for reduction of the power loss of PV modules (PV moudule의 출력손실 저감요인 분석)

  • Lee, Sang-Hun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.45-50
    • /
    • 2011
  • The efficiency of solar cell was about 4[%] in initial stage of photovoltaic industry, but it has quite a lot of efficiency through technology advances. Today, the efficiency of c-Si solar cells is about 17 to 19[%] and the efficiency of PV modules is about 14 to 15 [%]. We called that electrical losses occurred in the Conversion of solar cells to PV modules are CTM loss(Cell To Module loss), the CTM loss typically has a value of about3~5[%]. The more efficiency of solar cell increase, differences are larger because the efficiency decrease owing to physical or technical problems occurred in the Conversion of solar cells to PV modules. In this study, the power loss factors occurred in the Conversion of solar cells to PV modules are analyzed and it is proposed that how to reduce losses of the PV module. The types of power loss factor are (1)losses of front glass and encapsulant(generally EVA sheet), (2)losses by sorting miss, (3)losses by interconnection, (4)losses by the field aging of PV modules. In further study, experimental and evaluation will be conducted to make demonstrate for proposed solutions.

  • PDF

High-Voltage Liquid-Electrolyte Microbatteries Inspired from Electric Eels (전기뱀장어의 전기발생을 모사한 고전압 액체 전해질 미소전지)

  • Kim, Mun-Chul;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.469-473
    • /
    • 2009
  • We present high-voltage liquid-electrolyte microbatteries, inspired from the high-voltage generation mechanism of electric eels using serially connected multiple-cell arrays. In the microbatteries, we purge air into the electrolyte filled in a channel layer to isolate serially connected multiple cell arrays using three surface-tension valves (cell-front, outlet, and cell-end valves). Compared to the previous multi-cell stack or interconnection, present microbatteries provide a reduced multi-cell charging time. We have designed and characterized four different prototypes C1, C10, C20, and C40 having 1, 10, 20, and 40 cells, respectively. In the experimental study, the threshold pressures of cell-front, outlet, and cell-end valves were measured as $460{\pm}47$, $1,000{\pm}53$, and $2,800{\pm}170$ Pa, respectively. The average charging time for C40 was measured as $26.8{\pm}4.9$ seconds where the electrolyte and air flow-rates are 100 and $10{\mu}l/min$, respectively. Microbatteries showed the maximum voltage of 12 V (C40), the maximum power density of $110{\mu}W/cm^2$ (C40), and the maximum power capacity of $2.1{\mu}Ah/cm^2$ (C40). We also proposed a tapered-channel to remove the reaction gas from the cell chamber using a surface tension effect. The present microbatteries are applicable to high-voltage portable power devices.

Cell array multiplier in GF(p$^{m}$ ) using Current mode CMOS (전류모드 CMOS를 이용한 GF(P$^{m}$ )상의 셀 배열 승산기)

  • 최재석
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.3
    • /
    • pp.102-109
    • /
    • 2001
  • In this paper, a new multiplication algorithm which describes the methods of constructing a multiplierover GF(p$^{m}$ ) was presented. For the multiplication of two elements in the finite field, the multiplication formula was derived. Multiplier structures which can be constructed by this formula were considered as well. For example, both GF(3) multiplication module and GF(3) addition module were realized by current-mode CMOS technology. By using these operation modules the basic cell used in GF(3$^{m}$ ) multiplier was realized and verified by SPICE simulation tool. Proposed multipliers consisted of regular interconnection of simple cells use regular cellular arrays. So they are simply expansible for the multiplication of two elements in the finite field increasing the degree m.

  • PDF

ER-mediated stress induces mitochondrial-dependent caspases activation in NT2 neuron-like cells

  • Arduino, Daniela M.;Esteves, A. Raquel;Domingues, A. Filipa;Pereira, Claudia M.F.;Cardoso, Sandra M.;Oliveira, Catarina R.
    • BMB Reports
    • /
    • v.42 no.11
    • /
    • pp.719-724
    • /
    • 2009
  • Recent studies have revealed that endoplasmic reticulum (ER) disturbance is involved in the pathophysiology of neurodegenerative disorders, contributing to the activation of the ER stress-mediated apoptotic pathway. Therefore, we investigated here the molecular mechanisms underlying the ER-mitochondria axis, focusing on calcium as a potential mediator of cell death signals. Using NT2 cells treated with brefeldin A or tunicamycin, we observed that ER stress induces changes in the mitochondrial function, impairing mitochondrial membrane potential and distressing mitochondrial respiratory chain complex Moreover, stress stimuli at ER level evoked calcium fluxes between ER and mitochondria. Under these conditions, ER stress activated the unfolded protein response by an overexpression of GRP78, and also caspase-4 and-2, both involved upstream of caspase-9. Our findings show that ER and mitochondria interconnection plays a prominent role in the induction of neuronal cell death under particular stress circumstances.

Thle New Design of a Large Area Dye-sensitized Solar Cell with Ag Grid for Improving a Design Characteristics (설계적 특성 개선을 위한 Ag 그리드를 가지는 대면적 염료감응형 태양전지의 새로운 디자인)

  • Choi, Jin-Young;Lee, Im-Geun;Hong, Ji-Tae;Kim, Mi-Jeong;Kim, Whi-Young;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.123-127
    • /
    • 2007
  • Up sizing of dye-sensitized solar cell(DSC) is the important technology to bring about commercialization of DSC. Several studies to obtain a stable large area DSC have been investigated in overseas laboratories, but have been hardly done in our country. In this study, up sizing technology of dye sensitized solar cells(DSCs) was investigated. We investigated low dark current materials for the current collecting grid. From the result, a new DSC module with metal grid was designed, and fabricated. For a new interconnection, both working and counter electrodes are alternately coupled on 10[cm]$\times$7[cm] substrate. We have achieved 68% of fill factor and photoelectric conversion efficiency of around 2.6% as the best results of new designed DSC structure.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.