• 제목/요약/키워드: Cell Resistance

검색결과 2,450건 처리시간 0.035초

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

In Vitro Evaluation of Swine-Derived Lactobacillus reuteri: Probiotic Properties and Effects on Intestinal Porcine Epithelial Cells Challenged with Enterotoxigenic Escherichia coli K88

  • Wan, Zhilin;Wang, Li;Chen, Zhuang;Ma, Xianyong;Yang, Xuefen;Zhang, Jian;Jiang, Zongyong
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권6호
    • /
    • pp.1018-1025
    • /
    • 2016
  • Probiotics are considered as the best effective alternatives to antibiotics. The aim of this study was to characterize the probiotic potential of lactobacilli for use in swine farming by using in vitro evaluation methods. A total of 106 lactic acid bacterial isolates, originating from porcine feces, were first screened for the capacity to survive stresses considered important for putative probiotic strains. Sixteen isolates showed notable acid and bile resistance, antibacterial activity, and adherence to intestinal porcine epithelial cells (IPEC-1). One isolate, LR1, identified as Lactobacillus reuteri, was selected for extensive study of its probiotic and functional properties in IPEC-1 cell models. L. reuteri LR1 exhibited good adhesion to IPEC-1 cells and could inhibit the adhesion of enterotoxigenic Escherichia coli (ETEC) to IPEC-1 cells. L. reuteri LR1 could also modulate transcript and protein expression of cytokines involved in inflammation in IPEC-1 cells; the Lactobacillus strain inhibited the ETEC-induced expression of proinflammatory transcripts (IL-6 and TNF-α) and protein (IL-6), and increased the level of anti-inflammatory cytokine (IL-10). Measurement of the permeation of FD-4 showed that L. reuteri LR1 could maintain barrier integrity in monolayer IPEC-1 cells exposed to ETEC. Immunolocalization experiments showed L. reuteri LR1 could also prevent ETEC-induced tight junction ZO-1 disruption. Together, these results indicate that L. reuteri LR1 exhibits desirable probiotic properties and could be a potential probiotic for use in swine production.

벼 내도복 뽀얀멥쌀 신품종 '설갱' (A Lodging Tolerant, Opaque Rice Cultivar 'Seolgaeng')

  • 홍하철;문헌팔;최해춘;황홍구;김연규;김홍열;예종두;신영섭;강경호;최용환;조영찬;백만기;양창인;최임수;안상낙;양세준
    • 한국육종학회지
    • /
    • 제43권6호
    • /
    • pp.532-537
    • /
    • 2011
  • '설갱'은 다양한 전분소재를 육성할 목적으로 1991년 하계에 양질다수성 품종인 일품벼에 돌연변이 유도물질(MNU)을 처리하여 $M_1$세대 697개체를 얻었다. 1992년 하계온실에서 $M_2$세대 113개체를 선발하여 1992/'93 동계 온실에서 $M_3$집단을 육성하였다. $M_4$세대부터는 포장에서 계통선발법에 의해 주요 병충해 및 미질검정을 병행하여 다양한 전분 신소재 계통을 선발 고정시켰다. 중만생종이며 전분의 형태가 아밀로스 함량은 일반 메벼와 같고 투명도는 찰벼와 같은 뽀얀메 일품(MNU) 28-3-GH1-2-5-3 계통을 선발하여 '수원 461호'로 계통명을 부여한 후 1999년부터 2001년까지 3년간 지역적응시험 실시 결과 그 우수성이 인정되어 2001년 12월 직무육성 신품종 선정위원회에서 국가목록등재품종으로 선정됨과 동시에 '설갱' 으로 명명하였다. 그 주요 특성을 요약하면 다음과 같다. 1. '설갱'의 출수기는 보통기 보비재배에서 평균 출수기가 8월 21일로 화성벼보다 9일 늦은 중만생이며, 간장은 83 cm로 화성벼보다 6 cm 짧으며 이삭당 벼알수는 화성벼보다 23개 많으나 등숙률은 73.3%로 화성벼보다 14.3% 낮았다. 2. '설갱'은 잎도열병, 흰잎마름병, 바이러스병 및 멸구류에는 약한 반응을 보였다. 3. '설갱'은 내냉성에는 중강 정도의 특성이었으며, 벼 키와 3절 간장이 화성벼보다 짧고 도복지수가 낮아서 도복에 강하다. 4. '설갱' 쌀의 외관은 찹쌀과 같은 뽀얀특성을 지니고 있으나 아밀로스 함량은 19.3%로 일반메벼와 같은 특성을 보였으며, 식미 관능검정에서 밥맛이 화성벼보다 양호하였으나, 도정율은 화성벼보다 떨어졌다. 5. '설갱' 쌀의 발효적성 검정 결과 황국균 발효에서 일품벼보다 균사의 밀도 및 향이 우수하며 홍국균 고체 발효에서도 일품벼보다 색소 및 균사체 상태가 우수하였다. 6. '설갱'의 쌀 수량은 보통기 보비재배에서 평균 5.27 MT/ha으로 대비품종 화성벼 및 동진벼와 비슷하였고, 남부평야지 이모작 재배에서는 5.08 MT/ha로 동진벼보다 3% 감수하였으나, 만식재배에서는 5.75 MT/ha로 동진벼보다 6% 증수하였다. 7. 재배적지는 중부 및 남부 평야지이다.

대전광역시 월평공원과 전북 격포해수욕장 주변 야생화와 토양들로부터 야생효모의 분리 및 국내 미기록 효모들의 특성과 생리 활성 (Isolation of Wild Yeasts and Characterization of Physiological Functionalities of Unrecorded Wild Yeasts Obtained from Flowers and Soils of the Wolpyung Park, Daejeon City and Gykpo Beach, Buan, Jeollabuk-do in Korea)

  • 장지은;박선정;이종수
    • 한국균학회지
    • /
    • 제49권1호
    • /
    • pp.87-100
    • /
    • 2021
  • 많은 사람들이 다녀가는 도시공원과 해변 환경의 효모 특성을 알아보기 위해 대전광역시 월평공원 갑천 누리길과 내원사 주변의 야생화와 토양 75점에서 모두 88균주의 야생 효모들을 분리, 동정하였다. 또한 전북 부안의 격포해수욕장과 격포항 주변 야생화와 토양 35점에서 30균주의 야생 효모들을 분리하였다. 이들 분리 야생 효모들 중 A. porosum ASCM32-1, A. scarabaeorum WP49-1, C. athensensis WP4-90-3, C. berkhoutiae WP34-2, C. bracarensis WP35-1, Cy. amylophila GP19-1, K. gamospora WP9-1, M. carpophila BN-17-1, T. namnaoensis WP4-89-1, V. taibaiensis WP13-2 등 10종의 국내 미기록종 후보 균주들을 선별하여 균학적 특성을 확인하였다. 이들 미기록 효모들은 주로 구형~타원형으로 모두 출아방식으로 영양 증식을 하였고 V. taibaiensis WP13-2와 K. gamospora WP9-1, C. athensensis WP4-90-3 외 7종의 미기록 효모들은 자낭포자를 형성하지 않은 무포자 효모들이었으며A. porosum ASCM32-1만이 의균사를 생성하였다. 대부분의 균주들은 YPD 배지와 YM 배지에서생육하였고V. taibaiensis WP13-2와K. gamospora WP9-1, T. namnaoensis WP4-89-1 균주들은 15% NaCl을 함유한 YPD 배지에서 생육하는 호염성 효모들이었고, Cy. amylophila GP19-1 균주는 40℃에서도 생육하였다. C. athensensis WP4-90-3 균주 등 5균주들이 10% 에탄올 내성을 보였고C. athensensis WP4-90-3 균주는 Li2+ 등 많은 중금속들에 대해서 내성을 보였다. 국내 미기록 효모들과 비병원성 야생 효모 균주 무세포추출물들의 β-glucuronidase 저해 활성은 C. oleophila WP5-19-1의 무세포 추출물이 49.0%로 가장 높았고 미기록 효모인 K. gamospora WP9-1의 무세포 추출물도 27.7%를 보였다. 호중구 elastase 저해 활성은 W. anomalus HO9-2가 38.4%로 우수하여 건강 소재로 생산에 매우 유용한 균주로 활용될 것으로 기대된다.

테레프탈알데하이드의 전자전달 강화효과에 따른 헴 단백질 모방 촉매의 성능 향상 및 이를 이용한 비분리막형 과산화수소 연료전지 (Effect of Terephthalaldehyde to Facilitate Electron Transfer in Heme-mimic Catalyst and Its Use in Membraneless Hydrogen Peroxide Fuel Cell)

  • 전시은;안희연;정용진
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.588-593
    • /
    • 2022
  • 본 논문에서는 hemin, 폴리에틸렌이민(PEI) 및 탄소나노튜브(CNT)를 이용하여 제조 CNT/PEI/hemin/PEI 복합재에 가교제인 테레프탈알데하이드(TPA)를 첨가하여 전자전달이 개선된 과산화수소 환원 반응(HPRR) 촉매를 합성하였다. 합성된 촉매(CNT/PEI/hemin/PEI/TPA)를 과산화수소 10 mM 농도에서 HPRR 반응성을 확인한 결과, 0.2 V (vs. Ag/AgCl)에서 0.2813 mA cm-2의 전류 밀도로 나타났으며, 이는 가교하지 않은 촉매(CNT/PEI/hemin/PEI)와 범용 가교제인 글루타르알데하이드(GA)에 의해 가교된 촉매(CNT/PEI/hemin/PEI/GA)에 비해 각각 2.43 및 1.87배 증가하였다. CNT/PEI/hemin/PEI/TPA의 HPRR 개시전위는 0.544 V로서 CNT/PEI/hemin/PEI와 CNT/PEI/hemin/PEI/GA의 0.511 및 0.471 V에 비하여 원활한 전자전달에 의해 개선되었음을 확인할 수 있었다. 이는 전기화학 임피던스 분광법(EIS)을 이용한 분석 결과에서도 확인되었는데, CNT/PEI/hemin/PEI/GA의 경우, 전자전달을 방해하는 가교제의 도입에 따라 CNT/PEI/hemin/PEI에 비하여 높은 전자전달저항을 나타낸 반면, CNT/PEI/hemin/PEI/TPA는 6.2% 감소하여, 가장 낮은 전자전달저항을 나타냈다. 막이 없는 흐름형 과산화수소 연료전지를 이용한 평가에서도, CNT/PEI/hemin/PEI/TPA를 환원극으로 활용한 전지의 최대 출력 밀도가 36.34±1.41 μWcm-2로, CNT/PEI/hemin/PEI (27.87±0.95 μWcm-2)와 CNT/PEI/hemin/PEI/GA(25.57±1.32 μWcm-2) 보다 높게 측정되어, TPA는 전자전달을 개선 성능을 확인할 수 있었다.

무김치에서 분리한 Leuconostoc 속의 특성과 면역증강 효과 (Characteristics of Leuconostoc spp. isolated from radish kimchi and its immune enhancement effect)

  • 곽서연;유성의;박지언;정우수;권희민;여수환;김소영
    • 한국식품저장유통학회지
    • /
    • 제30권6호
    • /
    • pp.1082-1094
    • /
    • 2023
  • 본 연구는 무김치에서 우점균인 Leuconostoc속의 균주 특성을 살펴보고 유용한 균주를 발굴하여 소재화하기 위해 수행되었는데, 이들 Leuconostoc속 4균주의 효소학적 특성, 안전성 평가, 및 면역증강 효과는 양성대조구 LGG와 함께 비교·분석하였다. 효소활성 평가에서 모든 시험균주들은 벤조피렌과 같은 발암성 전구물질 생성과 연관된 β-glucuronidase 효소활성을 갖고 있지 않았고, β-1,4 당쇄결합을 유리시키는 β-glucosidase 효소활성을 나타내어 식품, 세제, 화학 등 여러 산업 분야로의 활용성을 기대할 수 있는 특징을 보유하고 있었다. 또한, 시험균주들에 대한 항생제 내성 평가결과는 8종 항생제들에 대해 MIC 값이 EFSA 기준치 이하로 감수성을 나타내었다. 용혈성 현상 실험 결과, 4종의 시험균주와 양성대조구로 사용된 LGG균은 모두 용혈능이 없는 감마 용혈 현상을 나타내었고, 병원성 미생물 4종에 대한 항균활성 결과에서도 Leu. mesenteroides K2-4 균주가 B. cereus와 Sta. aureus에 대하여 각각 19±0과 20±0 mm의 억제환을 나타내었는데, 이는 양성대조구인 LGG균보다 높은 항균활성을 보였다. 대식세포 RAW cell에 시험균주들을 처리하였을 때 NF-kB/AP-1 전사인자의 활성도는 모든 유산균주가 처리 농도가 낮을수록 농도 의존적으로 증가하였다. 이들 세포들에 의해 염증성매개물질 중 TNF-α와 IL-6의 생성량 역시 시험균주의 처리 농도가 낮을수록 높은 값을 보였는데, 특히 Leu. mesenteroides K2-4 균주는 모든 항목에서 다른 균주들에 비해 뚜렷한 차이를 보였다. 또한, mRNA 수준에서 TNF-α와 IL-6 발현량 역시 통계적 유의수준(p<0.05)으로 높은 활성을 저농도에서 처리하였을 때 유의적(p<0.05)으로 높은 값을 나타내었다. 따라서 이들 균주들이 분비한 사이토카인들은 T세포와 B세포를 자극하여 체내 면역체계를 활성화시켜 면역증강에 기여할 수 있을 것으로 사료된다. 종합적으로 본 연구에서 사용한 모든 Leuconostoc 균주들은 효소활성과 안전성이 확인되었는데, 그 중 Leu. mesenteroides K2-4균주가 높은 면역활성능을 보여, 향후 면역 기능 개선을 위한 건강기능식품 개발을 위한 후보소재로서 유용하게 이용될 수 있을 것으로 기대된다.

경기지역 학교 단체급식소 식품 및 환경 중 식중독균 분석 (Analysis of Foodborne Pathogens in Food and Environmental Samples from Foodservice Establishments at Schools in Gyeonggi Province)

  • 오태영;백승엽;구민선;이종경;김승민;박경민;황대근;김현정
    • 한국식품영양과학회지
    • /
    • 제44권12호
    • /
    • pp.1895-1904
    • /
    • 2015
  • 본 연구에서는 건당 환자수가 높아 식품안전관리 우선순위가 높은 단체급식소의 식품, 조리도구 및 환경에서 식중독균을 분석하고 이들 미생물의 병원성 인자 및 항생제 내성을 확인하여 미생물 위험분석을 위한 기본정보를 제공하고자 하였다. 경기도 소재 총 8개(농촌 3, 도시 4 및 벽지 1) 학교급식소에서 식품 시료(n=66), 조리도구(n=44) 및 환경 시료(n=56) 등 총 179점의 시료를 채취하여 지표세균 및 식중독균을 분석하였다. 식품 시료에서 총균수는 평균 4.7 log CFU/g, 최대 8.1 log CFU/g으로 대장균군의 평균 오염도 3.1 log CFU/g, 최대 오염도 4.0 log CFU/g으로 높았다. 선반 및 개수대 등 환경 시료의 총균수는 평균 2.7 log CFU/g, 최대 4.1 log CFU/g으로 식품 시료보다 낮은 수준으로 분석되었으나 대장균의 경우 평균 4.0 log CFU/g, 최대 5.4 log CFU/g으로 식품 시료보다 오염 수준이 높아 환경으로 부터의 교차오염 가능성을 배제할 수 없었다. 병원성 미생물 중 Bacillus cereus의 정량분석 결과 식품(원료, 조리단계 및 조리식품 포함) 시료에서 평균 2.1 log CFU/g, 최대 4.1 log CFU/g으로 분석되었으나, 이 중 조리된 식품의 오염도는 10,000 CFU/g 이하로 식품공전의 기준 이하로 오염되어 있었다. Escherichia coli는 식품 중 조리 전 시료(n=14)에서만 검출율 35.7%로 분석되었으며 조리단계의 식품, 조리도구 및 환경 시료에서는 검출되지 않았다. Staphylococcus aureus의 경우 조리 전 식품 원료(n=14)의 21.4%에서 검출되었으며 환경 시료(냉장고 손잡이)에서 1건 양성으로 검출되었고, 조리단계의 식품, 조리도구 및 환경 시료에서는 검출되지 않았다. 그 외 Clostridium perfringens, Listeria monocytogenes, Salmonella spp., Vibrio parahaemolyticus는 분석된 모든 시료에서 모두 음성이었다. 분리된 B. cereus의 독소유전자(hblACD, nheABC, entFM, cytK enterotoxin gene)를 분석한 결과 구토 유발 독소인 ces는 모두 음성이었으나 분석된 86주 모두 적어도 1종 이상의 설사 유발 독소유전자가 검출되었으며 66.2%의 균주는 설사 유발 독소유전자를 모두 보유하고 있었다. 식품과 환경에서 분리한 S. aureus(n=16)의 장독소 생성 유전자를 분석한 결과 모두 1종 이상의 독소유전자가 검출되었다. 전형적인 장독소유전자 중에서는 sea만 검출되었으며, 독소충격증후군 toxin(tst) 유전자는 모든 분리주에서 검출되지 않았다. 집단 식중독 발생 시 초기 진료에 결정적 영향을 주는 항생제 내성 여부를 분석한 결과 E. coli(n=41)의 92.7%는 분석한 항생제 16종에 대해 내성을 보이지 않았고 cefazolin에 대한 내성률이 4.9%로 가장 높았으며, 1개 균주에서만 2개 항생제에 대해 다제내성을 보여 국내외 항생제 내성률보다 낮았다. S. aureus(n=16)는 시험한 19종 항생제 중 gentamicin에 대한 내성률이 62.5%로 가장 높았으며 일부 균주에서 2주 항생제에 대해 다제내성이 관찰되었다. 한편 단체 급식소 2개소의 조리도구와 환경 중 미생물 군집을 분석한 결과 특정균이 도구와 환경에서 중복 검출되어 도구와 환경 중 교차오염 가능성을 간접적으로 시사하였다. 이와 같이 본 연구에서 단체급식소 식품, 조리도구 및 환경 중 위생지표균과 병원성 미생물의 오염패턴을 분석하고 분리된 균주의 독성인자와 항생제 내성 정보를 분석하였다. 관련 정보는 단체급식소 미생물 위험분석과 이를 바탕으로 사전적, 정량적 안전관리 기술 개발에 활용 가능할 것으로 사료된다. 한편 식중독 유발의 다른 원인인 바이러스류와 기타 원인에 대한 연구는 진행되지 않아 추가 연구가 필요하다.

포도 동해위험 판정기준으로서 온도시간 기반의 휴면심도 이용 (A Thermal Time-Driven Dormancy Index as a Complementary Criterion for Grape Vine Freeze Risk Evaluation)

  • 권은영;정재은;정유란;이승종;송기철;최동근;윤진일
    • 한국농림기상학회지
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 2006
  • 동계기온의 지속적인 상승에도 불구하고 낙엽과수의 동해발생빈도는 줄지 않고 있지만, 동해 경감을 위해 필수적인 사전경보시스템에 대한 연구는 미흡한 실정이다. 본 연구에서는 급격한 기후변화에 적응하지 못하는 기존의 '최저기온 의존 동해경보시스템'을 보완하기 위해 생물계절이론에 근거한 휴면심도를 동해위험도 판정의 추가기준으로 제시한다. 평년 기온자료와 생물계절모형에 근거한 휴면심도의 경시변화양상은 낙엽과수의 교과서적인 내동성 변화추세와 일치하였다. 개별 연도의 기온자료에 의해 추정된 휴면심도는 연차 변이가 현저하였으며 동일 연도 내 지역간 변이도 확인할 수 있었다. 전북 김제시 백구면 Campbell Early 주산지 10개 포도원을 대상으로 소기후모형과 인근 기상관서 기후자료에 의해 연도별 최저기온을 복원하고, 최저기온 발생일의 휴면심도를 생물계절모형으로 추정하였으며, 동해정도를 조사하였다. 최저기온휴면심도 피해율 사이의 관계를 분석하여 동해위험도 판정식을 작성하고, 이를 근거로 경북 영천, 충북 옥천, 충남 아산, 경기 화성 등 4개 포도 주산지 시군에 대해 1971-2000 평년의 동해위험지도를 30 m 공간해상도로 제작하였다. 화성지역의 경우 1996년의 동해사례에 의해 동해위험지도의 신뢰성을 부분적으로 검증할 수 있었다. 월동기간 중 실측기온자료에 의해 임의날짜의 휴면심도를 추정하고, 기상청 예보기온을 소기후모형에 의해 30m해상도의 국지기온 예상분포도로 변환한 다음, 내일 아침의 동해가능성을 동해위험도 판정식에 의해 판정할 수 있는 실시간 동해경보시스템을 설계하였다. 이 시스템의 실제 운영을 위해 필요한 프로그램을 작성하고 하드웨어를 갖추어 기상청 국가농업기상센터에 이전, 설치하였다. 산출되는 최저기온 및 동해위험정보는 표준지리정보로 가공되어 기상청 농업 기상정보서비스를 통해 시범적으로 제공될 예정이다.되지 않았으며 상처에 의하여서도 전혀 반응을 하지 않았다. 고에서는 이와 같은 비상통신과 관련하여 수행하고 있는 국외 비상통신 관련표준화 현황 및 해외 주요국가 별 구축 동향에 대해서 기술한다.급식성과는 급식경험 기간과 음(-)의 상관관계를, 아침식사횟수와는 양(+)의 상관관계를 보였으며, 서비스 품질의 특성 영역은 각 영역들에 대한 급식성과 점수가 높을수록 다른 영역의 급식성과 점수가 높은 유의적인(p <0.01) 양(+)의 상관관계를 보였다. 이상의 결과를 살펴볼 때, 균형된 영양공급이 다른 어느 시기보다 더 중요한 우리의 청소년들의 학교급식에 대한 만족도를 높이기 위해서 다음과 같은 제언을 하고자 한다. 먼저, 학교급식에 대한 식단 작성 시 학생들이 학교에서 제공되기 원하는 식단에 대한 의견을 받고 그 의견에 대한 결과를 게시하여 학생들이 제공되기 원하는 식단을 급식 시 제공하여 학생들이 식단선택에 동참할 수 있는 기회를 주는 것이 바람직하겠다. 또한 영양사는 학급의 반대표와의 정기적인 모임을 가짐으로서 학생들의 불만사항 및 개선 요구사항에대해 서로 의견을 교환하여 설문지조사가 아닌 직접적인 대화를 하여 문제점을 파악하고자 하는 적극적인 자세가 필요하겠다. 특히 아침식사의 결식 빈도가 높았고 이는 급식성과에 부정적인 영향을 줄 뿐 아니라 학교에서 제공하는 음식의 섭취정도에도 영향을 주고 있으므로 학생들에게 학부모와 전담교사 및 학교영양사는 학생들에게 이상적인 아침식사에 대한 교육은 물론이고 아침식사를 실천할 수 있도록 다양한 방안에 대해 함께 연구해야 하겠다. 정부차원에서 학교급식에 아침식사 프로그램을 도입할 수 있는 방안을 연구하고, 아침을 결식하는 학생이 학교에서 수업시작 하기 전에 간단한 식사를 할 수 있는 정책 도입이 필요하다acid의 생성량(生成量)을 측정(測定)하였는데 periodate의 소비량(消費量)은

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF