• Title/Summary/Keyword: Cell Lysis

Search Result 215, Processing Time 0.027 seconds

A Continuous Electrical Cell Lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow (한 쌍의 전극으로 전기 삼투 유동과 세포 분쇄 기능을 동시에 구현한 연속적인 세포 분쇄기)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.831-835
    • /
    • 2008
  • We present a continuous electrical cell lysis chip, using a DC bias voltage to generate the focused high electric field for cell lysis as well as the electroosmotic flow for cell transport. The previous cell lysis chips apply an AC voltage between micro-gap electrodes for cell lysis and use pumps or valves for cell transport. The present DC chip generates high electrical field by reducing the width of the channel between a DC electrode pair, while the previous AC chips reducing the gap between an AC electrode pair. The present chip performs continuous cell pumping without using additional flow source, while the previous chips need additional pumps or valves for the discontinuous cell loading and unloading in the lysis chambers. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present chip generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of Red Blood Cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of $30{\mu}m/s{\pm}9{\mu}m/s$. In conclusion, the present chip is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip.

Stomach Cancer Cell Lysis in PBS with Conductivity and Osmotic-Pressure Control (용액 전도도 및 삼투압 조절된 PBS에서의 위암 세포 전기 분해)

  • Kim, Min-Soo;Lee, Kook-Nyung;Cho, Su-Hyung;Kim, Byung-Gee;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2137-2139
    • /
    • 2004
  • Cancer cell lysis at pulsed DC is realized using micromachined electrodes. In this research, quantitative analyses are performed on cell lysis results. The cell volume increasing at the pulses applied are analyzed in different medium conditions on osmotic pressure and conductivity, and the cell lysis procedures are studied in detail experimentally. Phosphate buffered saline (PBS) is used as the medium. To change the conductivity of PBS, NaCl concentration of PBS is adjusted, and inositol is used with PBS to control the effects of the osmotic pressure to cell lysis performance.

  • PDF

Development of a Simple Cell Lysis Method for Recombinant DNA Using Bacteriophage Lambda Lysis Genes

  • Jang, Bo-Yun;Jung, Yun-A;Lim, Dong-Bin
    • Journal of Microbiology
    • /
    • v.45 no.6
    • /
    • pp.593-596
    • /
    • 2007
  • In this study, we describe the development of a simple and efficient method for cell lysis via the insertion of a bacteriophage lambda lysis gene cluster into the pET22b expression vector in the following order; the T7 promoter, a gene for a target protein intended for production, Sam7 and R. This insertion of R and Sam7 into pET22b exerted no detrimental effects on cellular growth or the production of a target protein. The induction of the T7 promoter did not in itself result in the autolysis of cells in culture but the harvested cells were readily broken by freezing and thawing. We compared the efficiency of the cell lysis technique by freezing and thawing to that observed with sonication, and determined that both methods completely disintegrated the cells and released proteins into the solution. With our modification of pET22b, the lysis of cells became quite simple, efficient, and reliable. This strategy may prove useful for a broad variety of applications, particularly in experiments requiring extensive cell breakage, including library screening and culture condition exploration, in addition to protein purification.

Comparison of Cell Lysis Techniques via Q-TOF LC/MS

  • Kaplan, Ozan;Oncul, Selin;Ercan, Ayse;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • v.11 no.2
    • /
    • pp.36-40
    • /
    • 2020
  • Untargeted metabolomics is a useful tool for drug development focusing on novel chemotherapeutic and chemopreventative agents against cancer cells. In recent years, quadrupole time of flight liquid chromatography-mass spectrometry (Q-TOF LC/MS)-based untargeted metabolomic approaches have gained importance to evaluate the effect of these agents at the molecular level. The researchers working on cell culture studies still do not apply standardized methodologies on sample preparation for untargeted metabolomics approaches. In this study, the rough and wet lysis techniques performed on MCF-7 breast cancer cells were compared with each other via the Q-TOF LC/MS-based metabolomic approach. The C18 and hydrophilic interaction liquid chromatography (HILIC) columns were used for the separation of the metabolites in MCF-7 cell lysates. 505 peaks were detected through the HILIC column and 551 peaks were found through the C18 column for the wet lysis technique. This situation supported by the base peak chromatograms showed that the wet lysis technique allowed us to extract higher number of non-polar metabolites. Almost equal number of metabolites was found for the C18 and HILIC columns (697 peaks for the HILIC column and 695 peaks for the C18 column) when the rough lysis technique was used. However, the intensities of polar metabolites were higher for the rough lysis technique on base peak chromatograms for both the HILIC and C18 columns. Although cell lysis technique, which is the first step in the sample preparation for cell culture studies, does not cause dramatic differences in the number of the detected metabolite peaks, it affects the polar and non-polar metabolite ratio significantly. Therefore, it must be considered carefully especially for in vitro drug development studies.

Study on Microbiochip for Buccal Cell Lysis and DNA Purification (상피세포 시료 전처리용 마이크로바이오칩에 관한 연구)

  • Ha, Seung-Mo;Cho, Woong;Ahn, Yoo-Min;Hwang, Seung-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1785-1791
    • /
    • 2010
  • This paper describes a separable microfluidic device fabricated with PDMS (polydimethylsiloxane) and glass. The device is used for sample preparation involving cell lysis and the DNA purification process. The cell lysis was performed for 2 min at $80^{\circ}C$ in a serpentine-type microreactor ($20 {\mu}l$) using a Au microheater that was integrated with a thermal microsensor on a glass substrate. The DNA that was mixed with other residual products during the cell lysis process was then filtered through a new filtration system composed of microbeads (diameter: $50 {\mu}m$) and PDMS pillars. Since the entire process (sample loading, cell lysis reaction, DNA purification, and sample extraction) was performed within 5 min in a microchip, we could reduce the sample preparation time in comparison with that for the conventional methods used in biochemistry laboratories. Finally, we verified the performance of the sample preparation chip by conducting PCR (polymerase chain reaction) analysis of the chip product.

Statistical Optimization of the Lysis Agents for Gram-negative Bacterial Cells in a Microfluidic Device

  • Kim, Young-Bum;Park, Ji-Ho;Chang, Woo-Jin;Koo, Yoon-Mo;Kim, Eun-Ki;Kim, Jin-Hwan
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.4
    • /
    • pp.288-292
    • /
    • 2006
  • Through statistically designed experiments, lysis agents were optimized to effectively disrupt bacterial cells in a microfluidic device. Most surfactants caused the efficient lysis of Gram-positive microbes, but not of Gram-negative bacteria. A Plackett-Burman design was used to select the components that increase the efficiency of the lysis of the Gram-negative bacteria Escherichia coli. Using this experimental design, both lysozyme and benzalkonium chloride were shown to significantly increase the cell lysis efficiency, and ATP was extracted in proportion to the lysis efficiency. Benzalkonium chloride affected the cell membrane physically, while lysozyme destroyed the cell wall, and the amount of ATP extracted increased through the synergistic interaction of these two components. The two-factor response-surface design method was used to determine the optimum concentrations of lysozyme and benzalkonium chloride, which were found to be 202 and 99 ppm, respectively. The lysis effect was further verified by microscopic observations in the microchannels. These results indicate that Gram-negative cells can be lysed efficiently in a microfluidic device, thereby allowing the rapid detection of bacterial cells using a bioluminescence-based assay of the released ATP.

Bio-inspired Cell Deformability Monitoring Chips Based on Strain Dependent Digital Lysis Rates (미소유로의 길이에 따른 통과세포의 파괴율을 바탕으로 한 생체모사 세포 변형성 검사칩에 관한 연구)

  • Youn, Se-Chan;Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.844-849
    • /
    • 2008
  • We present a novel cell deformability monitoring chip based on the digitally measured cell lysis rate which is dependent on the areal strain of the cell membrane. This method offers simple cell deformability monitoring by automated high-throughput testing system. We suggest the filter design considering the areal strain imposed on the cell membrane passing through the filter array having gradually increased orifice length. In the experiment using erythrocytes, we characterized the cell deformability in terms of average fracture areal strain which was $0.24{\pm}0.014\;and\;0.21{\pm}0.002$ for normal and chemically treated erythrocytes, respectively. We also verified that the areal strain of 0.15 effectively discriminates the deformability difference of normal and chemically treated erythrocytes, which can be applied to the clinical situation. We compared the lysis rates and their difference for the samples from different donors and found that the present chips can be commonly used without any calibration process. The experimental results demonstrate the simple structure and high performance of the present cell deformability monitoring chips, applicable to simple and cost-effective cell aging process monitoring.

A New Method for Determination of Enzyme Reaction and Activity of Lysozyme with UV-Spectrophotometer (UV-분광광도계를 이용한 새로운 Lysozyme의 효소반응 및 활성측정법 연구)

  • Kim, Woon-Soo;Kim, Yong-Wook;Kim, Woo-Sik
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.857-863
    • /
    • 1998
  • A simple and new experimental method for determination of lysozyme-M. lysodeikticus cell lysis reaction and lysozyme activity was suggested using Beer's law. The UV transmittance of the solution changed with the concentration of M. lysodeikticus and the relationship between the UV transmittance and M. lysodeikticus cell concentration followed Beer's Law. In addition, it was experimentally proven that the UV transmittance of the solution was not influenced by the lysozyme concentration and product of the lysis reaction. During the lysozyme-M. lysodeikticus cell lysis reaction, thus, M. lysodeikticus cell concentration in the solution could be measured in-situ by UV-spectrophotometer. By using these experimental data, kinetic Parameters of the Michaelis-Menten equation for the lysozyme-M. lysodeikticus cell 1ysis reaction was simply determined The maximum reaction rate constant ($k_3$) and Michaelis-Menten constants were $0.1734sec^{-1}$ and $9.83{\times}10^{-6}M$ respectively. The activity of the lysozyme could also be obtained with this experiment because the lysis reaction rate of the 1ysozyme depended on its activity.

  • PDF

Spontaneous Tumor Lysis Syndrome Presenting Acute Kidney Injury with Extreme Hyperuricemia and Urinary Stone: A Rare Case of Spontaneous Tumor Lysis Syndrome

  • Kim, Seong Heon;Yang, Eu Jeen;Lim, Young Tak;Kim, Su Young
    • Childhood Kidney Diseases
    • /
    • v.21 no.1
    • /
    • pp.31-34
    • /
    • 2017
  • Tumor lysis syndrome is a serious complication of malignancy, resulting from the massive and rapid release of cellular components into the blood. Generally, it occurs after initiation of chemotherapy. The onset of spontaneous tumor lysis syndrome (STLS) before anti-cancer treatment is rare and occurs mostly in Burkitt lymphoma and non-Hodgkin's lymphoma. There are only a few case reports in children. Here, we report a case of STLS secondary to T-cell acute lymphoblastic leukemia (ALL), which presented with urinary stone and subsequent acute kidney injury with severe hyperuricemia. Occult malignancy should be considered in case of unexplained acute kidney injury with extreme hyperuricemia.

Lysis Action of Lauric Acid on Bacillus subtilis var. niger (Bacillus subtilis var. niger에 대한 Lauric Acid의 용균작용)

  • 조석금;조효현
    • The Korean Journal of Food And Nutrition
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 1990
  • Effect of lauric acid and whir derivatives on the growth of Bacillus subtilis var niger was studied. Lauric acid showed the strongest inhibition among the fatty acids tested, Lysis rate of lauric acid proved to be greatly sensitibility against logarithmic phase cells but was not so influenced by cell concentration. On the other hand, lauric acid was inhibited lysis activity when the pH shift from 7.0 to 5.5

  • PDF