• Title/Summary/Keyword: CdTe detector

검색결과 80건 처리시간 0.022초

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

  • Lee, Jun;Kim, Younghak;Bolotnikov, Aleksey;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4080-4092
    • /
    • 2021
  • In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm3. The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80%), while those evaluated using the minimum squared difference method (55-59%) and Three Compton method (45-55%) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

EFFECT OF METAL CONTACT ON THE CZT DETECTOR PERFORMANCE

  • Park, Se-Hwan;Park, Hyung-Sik;Lee, Jae-Hyung;Kin, Han-Soo;Ha, Jang-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.65-68
    • /
    • 2009
  • Metal-semiconductor contact is very important for the operating property of semiconductor detector. $Cd_{0.96}$ $Zn_{0.04}$ Te semiconductor crystal was grown with Bridgman method, and the crystal was cut and polished. EPMA (Electron Probe Micro Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry) analysis were done to obtain the chemical composition and impurity of the crystal. Metal contact was deposited with thermal evaporator on both sides of the crystal. Detectors with Au/CZT/Au and In/CZT/Au structure were made, and I-V curve and the energy spectrum were measured with the detectors. It could be seen that the detector with the In/CZT/Au structure has superior property than the detector with Au/CZT/Au structure when the crystal resistivity was low. However, the metal contact structure effect becomes low when the crystal resistivity was high.

Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

  • Coulon, Romain;Dumazert, Jonathan;Tith, Tola;Rohee, Emmanuel;Boudergui, Karim
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1489-1494
    • /
    • 2017
  • The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, and $LaBr_3:Ce$. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

선형 종ㆍ원적외선 이중대역 동시 검출기배열을 위한 신호취득회로의 설계 (Design of readout circuit for linear two-color infrared detector array)

  • 김철범;우두형;강상구;이희철
    • 대한전자공학회논문지SD
    • /
    • 제41권9호
    • /
    • pp.49-56
    • /
    • 2004
  • HgCdTe 64×2 중원적외선 이중대역 동시검출기를 위한 포화전류차단 회로를 갖는 BDI입력방식의 신호취득회로(ROIC)를 설계하였다. 제안된 포화차단 회로를 통해서 중적외선 신호가 포화되면 원적외선 신호도 왜곡이 일어나던 기존의 문제점을 해결함으로써 120k정도 더 넓은 온도 영역의 물체까지 측정할 수 있는 범위를 확보하고 중적외선 검출기에서 발생하는 dead pixel에 의해 원적외선 검출기의 성능은 영향받지 않는 특성을 보였다. 회로 제작에 사용한 공정은 0.Sum 2-poly 3-metal Hynix CMOS 공정이었다. 측정결과 중적외선 신호와 원적외선 신호가 동시에 처리되는 것을 확인할 수 있었다. 또한, 측정된 잡음의 크기는 상온에서 53uV로서 동작온도 77K의 값으로 환산시켜 보았을 때 27uV로 ROIC의 특성이95% BLIP 조건을 만족함을 알 수 있었다.

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

카드뮴 텔룰라이드 CMP 공정에서 산화제가 연마에 미치는 영향 (Effect of Oxidizer on the Polishing in Cadmium Telluride CMP)

  • 신병철;이창석;정해도
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.69-74
    • /
    • 2015
  • Cadmium telluride (CdTe) is being developed for thin film of the X-Ray detector recently. But a rough surface of the CdTe should be improved for resolution and signal speed. This paper shows the study on the improvement of surface roughness and removal rate by applying Chemical Mechanical Polishing. The conventional potassium hydroxide (KOH) based colloidal silica slurry could not realize a mirror surface without physical defects, resulting in low material removal rate and many scratches on surface. In order to enhance chemical reaction such as form oxidized layer on the surface of cadmium telluride, we used hydrogen peroxide ($H_2O_2$) as an oxidizer. Consequently, in case of 3 wt% concentration of hydrogen peroxide, the highest MRR (938 nm/min) and the lowest surface roughness ($R_{p-v}=10.69nm$, $R_a=0.8nm$) could be obtained. EDS was also used to confirm the generated oxide of cadmium telluride surface.

방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작 (Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System)

  • 송관훈;김광수
    • 전자공학회논문지
    • /
    • 제51권4호
    • /
    • pp.193-200
    • /
    • 2014
  • 본 논문에서는 방사성 의약품의 자동합성장치에 사용되는 단채널 감마선 분광기를 보드 형태로 설계, 제작하고 그 특성을 측정 분석하였다. 감마선 검출을 위해 CZT (CdZnTe) spear 검출기를 이용하였고 아날로그 방식을 적용한 신호처리 보드의 형태로 감마선 분광기를 제작하였다. 측정을 위하여 방사성 물질인 Co-60을 시료로 사용하였으며, 최대 1173keV까지의 감마선 에너지 스펙트럼을 얻을 수 있었다. 아날로그 보드는 CZT spear 검출기에서 감마선을 검출하여 출력하는 신호를 적절히 변화시켜주기 위한 SF (shaping filter) 및 PHA (peak and hold amplifier)와 수치화된 감마선 신호 데이터를 계산하기 위한 ADC(analog to digital converter)와 FPGA (field programmable gate array)로 구성되었다.

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

CZT검출기를 이용한 CT/SPECT 조합영상시스템 (Combined X-ray CT/SPECT System with a Common CZT Detector)

  • 권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.229-233
    • /
    • 2002
  • CdZnTe 검출기를 제작하고 CT/SPECT 조합영상 시스템에 설치하여 엑스선 및 감마선검출기로서의 응용가능성을 타진해 보았다. 검출기의 크기는 10$\times$10$\times$5 ㎣ 이었다. 양극은 4$\times$4 픽셀로 설계하였으며 각 픽셀의 크기는 $1.5\times$l.5 $\textrm{mm}^2$ 이었다. 음극은 Au로 전극을 만들어 주었다. 시스템의 성능을 조사하기 위해서 방사선촬영용 분해능팬텀과 호프만 뇌 팬텀을 사용하였다. X선 영상에서 고광자방출율을 만족시키기 위해서 shapping time은 50ns 로 하었으며, 3$\times$$10^{5}$ counts/s 까지 선형성이 유지되었다. Tc-99m의 140 keV 감마선에 대한 에너지 분해능은 50 ㎱와 2 $\mu\textrm{s}$ shaping time을 걸어주었을 때 각각 10.4%와 5.3%이었다. CT와 SPECT의 공간분해능은 각각 1 mm와 9 mm 이었다. 광피이크 효율은 50 ㎱와 2 $\mu\textrm{s}$일 때 각각 41.0%와 72.5%이었다.

  • PDF