• Title/Summary/Keyword: Cavity thickness

Search Result 319, Processing Time 0.028 seconds

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF

Robust Design for Showerhead Thermal Deformation

  • Gong, Dae-Wi;Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF

Intrapulpal Temperature Change during Cavity Preparation on the Enamel and Dentin with an Er:YAG Laser (Er:YAG 레이저를 이용한 법랑질 및 상아질 와동 형성시의 치수내 온도변화)

  • Yang, Hee-Young;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The purpose of our study was to investigate whether the intrapulpal temperature during cavity preparation of enamel or dentin with Er:YAG laser still remained in range of safety for dental pulp protection when combined with appropriate water flow rate. The effect of different pulse repetition rates at the same pulse energy during ablation was evaluated as well. Caries-free, restoration-free extracted human molar teeth were prepared for the specimen and divided two experimental groups of enamel and dentin. Each group comprised 5 specimens and each of tooth specimens were embedded into a resin block each and measuring probe was placed on the irradiated pulpal walls. For experiments of dentin ablation, enamel layers were prepared to produce dentin specimen with a same dentin thickness of 2 mm. A pulse energy of Er:YAG laser was set to 300 mJ and three different pulse repetition rates of 20 Hz, 15 Hz and 10 Hz were employed. Laser beam was delivered with 3 seconds and less per application over enamel and dentin surfaces constant sized by $3\;mm{\times}2\;mm$ and water spray added during irradiation was a rate of 1.6 ml/min. Temperature change induced by Er:YAG laser irradiation was monitored and recorded While enamel was ablated, there was no significant difference of temperature related to pulse repetition rates(p=0.358) and temperature change at any pulse repetition rate was negligible. Significant statistical difference in temperature changes during cavity preparation in dentin existed among three different pulse groups(p=0.001). While temperature rise was noticeable when the dentinal wall was perforated, actual change of temperature due to Er:YAG laser irradiation was not enough to compromise safety of dental pulp when irradiation was conjugated with appropriate water spray. Conclusively, it can be said that cavity preparation on enamel or dentin with an Er:YAG laser is performed safely without pulp damage if appropriate volume of water is sprayed properly over the irradiated site.

AN EXPERIMENTAL STUDY OF THE EFFECTS ON THE BONE TISSUE BY IMPLANT OF ROOT CANAL FILLING MATERIALS (근관충전재(根管充塡材)의 매식(埋植)이 골조직(骨組織)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Chung, Jae-Kyoo;Min, Byung-Soon;Chi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.9 no.1
    • /
    • pp.25-35
    • /
    • 1983
  • The purpose of this study was the observe the toxic effects of root canal sealers in 108 white rats. Experimental animals were divided into control and experimental groups. Theree representative types of materials, such as AH26, Z.O.E. and F.R. were used in this study. Cavities were prepared on the left mandibular area of 108 white rats. Three different sealers were placed in as experiment and bone cavities were left without filling as control. The experimental animals were sacrificed by cervical dislocation at the intervals of 1, 3, 7, 14, 28 and 49 days after filling. Each specimen was fixed with 10% neutral formalin solution, decalcified with 5% nitric acid, embedded in paraffin and sectioned 5-7${\mu}$. in thickness. The paraffin sections stained with Hematoxylin - Eosin were observed through the ordinary light microscope. The results were as follows; 1. Slight toxic effect to surrounding tissue were found in every experimental specimen. 2. AH26 showed the highest inflammatory response, and F.R. showed the lowest inflammatory response which subsided and replaced by fibrosis at 4 weeks after filling. 3. The cavity filled materials, such as implanted root canal sealers, blood clots and necrotic tissue, showed a tendency to be absorbed gradually proportioned to the experimental periods. A small amount of cavity filled materials were observed in the bone cavities after 4 weeks. 4. Fibroblastic proliferation began to produce fibrous capsule around the bone cavity in 2 weeks after filling. Fibrosis was prominent at 4 weeks after filling. 5. Osteoblastic activity of surrounding bone was observed at first in 2 weeks after filling and prominent in 4 weeks after filling. Osteoblastic activity showed an increasing effect as the time prolonged. 6. Surrounding tissue of the bone cavities showed the features of tissue destruction and had very severe inflammatory response at an initial stage. Above-mentioned appeared to be recovered gradually proportioned to the experimental periods.

  • PDF

Reconstruction of Hard Palatal Defect using Staged Operation of the Prelaminated Radial Forearm Free Flap (부분층 피부이식으로 전판상화된 전완유리피판을 이용한 경구개 결손의 재건)

  • Choi, Eui Chul;Kim, Jun Hyuk;Nam, Doo Hyun;Lee, Young Man;Tak, Min Sung
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.53-57
    • /
    • 2010
  • Purpose: The radial forearm fasciocutaneous free flap is currently considered as the ideal free flap for reconstruction of mucosal and soft tissue defects of the palate. But the availability of stably attached oral and nasal mucosal lining is needed. In addition to this, for better operation field, operating convenience and esthetics, we planned a prelaminated radial forearm free flap. Methods: A 64-year-old male patient was admitted due to a $4{\times}4.5cm$ full through defect in the middle of the hard palate caused by peripheral T cell lymphoma with actinomycosis. In the first stage, the radial forearm flap was elevated, tailored to fit the hard palate defect, and then it positioned up-side down with split thickness skin graft. Two weeks later, the prelaminated radial forearm free flap was re-elevated and transferred to the palatal defect. One side covered with grafted skin was used to line the nasal cavity, and the other side (the cutaneous portion of the radial forearm flap) was used to line the oral cavity. Results: The prelamination procedure was relatively easy and useful. The skin graft was well taken to the flap. After 2nd stage operation, the flap survived uneventfully. There was no prolapse of the inset flap into the oral cavity and the cutaneous portion of the flap was mucosalized. The procedure was very successful and the patient can enjoy normal rigid diet and speech. Conclusion: The use of prelaminated radial forearm free flap for hard palate reconstruction is an excellent method to restore oral function. Based upon the result of this case, microvascular free flap transfer with prelaminated procedure is a valid alternative to the prosthetic obturator for palatal defect that provides an improved quality of life. It should be considered as an integral component of head and neck cancer therapy and rehabilitation.

THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN (유동성 레진의 두께가 미세누출에 미치는 영향)

  • Song, Gi-Gang;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.363-371
    • /
    • 2005
  • This study investigated the effect of thickness of flowable resin lining on marginal leakage in class II composite restorations. 80 experimental teeth were prepared with class II preparations with enamel margin or dentin margin. Each group was devided into four groups according to flowable resin lining thickness ; Control group - no flowable resin lining, Group 1 - 0.5 mm flowable resin lining, Group 2 - 1 mm flowable resin lining, Group 3 - 2 mm flowable resin lining. The cavities were restored using Scotchbond Multi-Purpose adhesive system, Filtek Flow and Filtek Z 250 composite resin. Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles and immersed in $2\%$ methylene blue for 24 hours. The results of this study were as follows : 1. Ranking of mean microleakage scores at the enamel margins was Group 1 < Control = Group 2 < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 and Group 2 (p < 0.05). 2. Ranking of mean microleakage scores at the dentin margins was Group 1 < Group 2 < Control < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 (p < 0.05) 3. Compared with microleakage between the enamel and dentin margins, enamel margin group were significantly lower than dentin margin group.

Non-exposure Simple Suturing Endoscopic Full-thickness Resection with Sentinel Basin Dissection in Patients with Early Gastric Cancer: the SENORITA 3 Pilot Study

  • Eom, Bang Wool;Kim, Chan Gyoo;Kook, Myeong-Cherl;Yoon, Hong Man;Ryu, Keun Won;Kim, Young-Woo;Rho, Ji Yoon;Kim, Young-Il;Lee, Jong Yeul;Choi, Il Ju
    • Journal of Gastric Cancer
    • /
    • v.20 no.3
    • /
    • pp.245-255
    • /
    • 2020
  • Purpose: Recently, non-exposure simple suturing endoscopic full-thickness resection (NESS-EFTR) was developed to prevent tumor exposure to the peritoneal cavity. This study aimed to evaluate the feasibility of NESS-EFTR with sentinel basin dissection for early gastric cancer (EGC). Materials and Methods: This was the prospective SENORITA 3 pilot. From July 2017 to January 2018, 20 patients with EGC smaller than 3 cm without an absolute indication for endoscopic submucosal dissection were enrolled. The sentinel basin was detected using Tc99m-phytate and indocyanine green, and the NESS-EFTR procedure was performed when all sentinel basin nodes were tumor-free on frozen pathologic examination. We evaluated the complete resection and intraoperative perforation rates as well as the incidence of postoperative complications. Results: Among the 20 enrolled patients, one dropped out due to large tumor size, while another underwent conventional laparoscopic gastrectomy due to metastatic sentinel lymph nodes. All NESS-EFTR procedures were performed in 17 of the 18 other patients (94.4%) without conversion, and the complete resection rate was 83.3% (15/18). The intraoperative perforation rate was 27.8% (5/18), and endoscopic clipping or laparoscopic suturing or stapling was performed at the perforation site. There was one case of postoperative complications treated with endoscopic clipping; the others were discharged without any event. Conclusions: NESS-EFTR with sentinel basin dissection is a technically challenging procedure that obtains safe margins, prevents intraoperative perforation, and may be a treatment option for EGC after additional experience.

Optimization of multiple-quantum-well structures in 1.55.$\mu$ InGaAsP/InGaAsP SL-MQW DFB-LD for high-speed direct modulation (고속직접변조를 위한 1.55.$\mu$. InGaAsP/InGaAsP SL-MQW DFB-LD의 양자우물구조의 최적화)

  • 심종인;한백형
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.3
    • /
    • pp.60-73
    • /
    • 1997
  • By introducing a compressive-strained quanternary InGaAsP quantum-wells instead of a conventional ternary InGaAs quantum-wells in 1.55.mu.m DFB-LD, the lasing performances canb e improved and the problems caused by the thickness non-uniformity and the compositional abruptness among the hetero-interpaces canb e relaxed. In this paper, we investigated an iptimum InGaAsP/InGaAsP multiple-quantum-well(MQW) structure as an active layer in a direct-modulated 1.55.mu. DFB-LD from the view point of threshold current, chirping charcteristics, and resonance frequency. The optimum compressive-strained MQW structure was revealed as InGaAsP/InGaAsP structure with strain amount of about 1.2%, number of wells $N_{w}$ of 7, well width $L_{w}$ of 58.agns.. The threshold current density J of 500A/c $m^{2}$, the linewidth enhancement factor a of 1.8, and differential resonance frequency of d $f_{r}$/d(I-I)$^{1}$2/=2GHz/(mA)$^{1}$2/(atI=2 $I_{th}$) were expected in 1.55.mu.m .gamma./4-shifted DFB-LD with the cavity length of 400.mu.m long and kL value of 1.25. These values are considerably improved ones compared to those of 1.55um DFB-LD with InGaAs/InGaAsP MQW which have enhancement factor and the resonance frequence frequency by the detuning of lasing wavelength and gain-peak wavelength. It was found that the linewidth enhancement factor of 20% and differential resonance frequency of 35% without the degradation of the threshold current density could be enhanced in the range of -15nm~-20nm detuning which can be realized by controlling the thickness and Incomposition of InGaAsP well. well.and Incomposition of InGaAsP well. well.

  • PDF

Lung Lobe Torsion with Concurrent Intestinal Lymphangiectasia in a Maltese Dog (Maltese 개에서 림프관 확장증을 동반한 폐염전 발생 증례)

  • Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.262-266
    • /
    • 2011
  • A 4-year-old intact male, Maltese dog weighing 2.2 kg was presented for evaluation of tachypnea and hyperthermia. On initial evaluation, the dog was dyspneic, but alert and responsive. Muffled heart sound was noted with auscultation of the right hemithorax. The radiographic findings were consolidation of the right middle lung lobe, pleural effusion, and abdominal fluid accumulation. Thoracic computed tomography confirmed a contrast-enhancing mass within the right middle lung lobe. Surgical exploration of the thoracic cavity was performed using a right fifth intercostal thoracotomy. Examination of the right lung lobe revealed $360^{\circ}C$ torsion of the right middle lung lobe at the level of the hilus, in a clockwise direction. Lung lobectomy was performed using a thoracoabdominal stapling device with 2.5-mm vascular staples. Full-thickness intestinal biopsy by exploratory laparotomy was taken from the jejunum for histological assessment. Histopathologic examination of the full-thickness intestinal biopsy revealed distended lacteal located within the submucosa of the jejunum. Intestinal lymphangiectasia was resolved with prednisone and low fat diets. Subsequent communication with the owner revealed that the patient was in good health 6 months post-discharge.

Malignant Fibrous Histocytoma Originating from the Chest Wall (흉부에서 발생한 악성 섬유성 조직구종)

  • Lee, Chul-Burm;Chung, Tae-Yul;Halm, Shee-Young;Kim, Hyuk;Jung, Won-Sang;Kim, Young-Hak;Kang, Jung-Ho;Jee, Heng-Ok;Park, Yong-Wook
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.333-337
    • /
    • 2000
  • Malignant fibrous histiocytoma(MFH) is a deep-seated pleomorphic sarcoma, which occurs principally as a mass of the extremities, abdominal cavity, or retroperitoneum in adults. However, it only rarely occurs in the chest wall. An 85-year-old man had undeergone excision of a small mass on the right posterior chest wall under local anesthesia 14 months age. However, the lesion did not heal and the mass recurred. He was referred to our hospital after the mass had grown to a size of 10.5$\times$8$\times$4cm with a 3$\times$3cm skin defect. Intraoperative frozen biopsy revealed MFH. An en-bloc wide resection and thin-thickness skin graft from his thigh were performed. Although distant metastasis to the lund developed 14 months later and the patient died 2 months later, there was no local recurrence. Thin-thickness skin graft is a simple method for a wide range skin defect, especially in the old age. He recovered in good condition without any physical disabilities.

  • PDF