• 제목/요약/키워드: Cavity of Class V

검색결과 80건 처리시간 0.026초

단일 단계 접착제의 변연 미세누출 (MARGINAL MICROLEAKAGE OF SINGLE STEP ADHESIVES)

  • 조영곤;정진호;기영재;최희영;진철희;유상훈;김종욱;박병철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.162-169
    • /
    • 2004
  • This study evaluated the marginal microleakage of five single step adhesives. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of the single step adhesives and composite resins:Prompt L-Pop/Filtek Z-250 (Group 1), AQ Bond/Metafil CX (Group 2), One-Up Bond F/Palfique Toughwell (Group 3). Futurabond/Admira (Group 4), Xeno III/Spectrum TPH (Group 5). The restored teeth were thermocycled. Microleakage was assessed by dye penetration using 2% methylene blue dye solution. The teeth were bisected buccolingually and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kruskal-Wallis test and Mann-Whitney tests. The results of this study were as follows:1. Microleakage of enamel margins in group 3 was statistically higher than that in groups 1, 2, 4, 5 (p < 0.05). 2. Microleakage of dentin margins in group 1 was statistically higher than that in groups 2, 5, and that in group 3 was statistically higher than that in groups 2, 4, 5 (p < 0.05). 3. Dentin marginal microleakage was higher than enamel marginal microleakage in all experimental groups. In conclusion, Prompt L-Pop showed the least leakage at enamel margin, and AQ Bond showed at dentin margin in this study. Marginal miroleakage in dentin was higher than that in enamel.

수복물의 미세누출도와 변연적합도 측정에 사용되는 방법 사이의 상관 관계 평가 (ESTIMATION OF RELATION BETWEEN TECHNIQUES OF DYE PENETRATION FOR MICROLEA-KAGE AND SEM EVALUATION FOR MARGINAL ADAPTATION OF THE RESTORATION)

  • 황순주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.337-343
    • /
    • 2006
  • 본 연구에서는 색소 침투법을 이용한 5급 복합레진 수복물의 미세누출도와 주사전자 현미경을 이용한 변연적합도를 측정하고 두 방법 사이의 상관성을 평가하고자 하였다. 발거된 사람의 대구치 20개의 협면에 고속의 330번 버를 이용하여 5급 와동을 (백아법랑경계부를 중앙으로 가로 4 mm, 세로 3 mm, 깊이 1.5 mm) 형성하고, 평가시 참고점으로 사용하고자 1/2번 원형 버로 6개의 함몰부를 만들었다. 제조사의 지시에 따라 단일 단계의 올인원 접착제인 Xeno III로 치면을 처리한 다음, 미세혼합형 복합레진인 Esthet X로 단일 충전하였다. 시편을 식염수에 1일간 보관한 후 Sof-Lex 시스템으로 마무리 및 연마하였다. 이후 5도와 55도에서 1000회 열순환시킨 다음, 50%질산은 용액을 이용하여 침투시켰다. 실리콘 고무 인상재와 폴리우레탄 모형재로 수복물 주변의 레진 복제물을 제작하고 금도금한 다음 주사전자현미경으로 외부 및 내부 변연부의 변연적합도를 측정하였다. 또한 참고점을 기점으로 수복물을 3분한 다음, 미세누출도를 측정하였다. 내부 및 외부 변연적합도와 미세누출도 평가법 사이의 상관관계는 Spearman's rho test를 이용하여 다음과 같은 결과를 얻었다. 1. 미세누출도와 각각의 외부 및 내부 변연 적합도는 유의한 상관관계를 보였다 (p <0.01). 2.내부와 외부의 변연 적합도 사이에는 유의한 상관관계를 보이지 않았다.

Glass Ionomer Cement의 방사선 불투과성에 관한 연구 (A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS)

  • 박수경;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

5급 와동의 복합레진 수복 시 발생되는 교두굴곡에 관한 연구 (CUSPAL DEFLECTION IN CLASS V CAVITIES RESTORED WITH COMPOSITE RESINS)

  • 박준규;임범순;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.83-89
    • /
    • 2008
  • 본 연구의 목적은 복합레진의 중합수축과 탄성계수가 5급 와동 수복시 교두굴곡에 미치는 영향을 평가하기 위함이다. 16개의 발치된 상악 소구치를 평균 크기가 비슷하게 2개의 group으로 분류하였다. 각각의 치아에 5급 와동을 형성하여 유동성 복합레진 (Filtek flow)과 전구치 수복용 hybrid복합레진 (Z-250)으로 각 group을 충전하였을 때 나타나는 교두굴곡을 측정하였으며 그 후 수복단면을 주사전자현미경 (SEM)으로 관찰하였다. 각 복합레진의 중합수축률과 탄성계수를 측정하여 교두굴곡에 미치는 영향을 고찰하였고 다음과 같은 결과를 얻었다. 1. Filtek flow와 Z-250으로 충전한 group에서 교두굴곡량은 각각 $2.18\;{\pm}\;0.92\;{\mu}m$$2.95\;{\pm}\;1.13\;{\mu}m$으로 나타나 Filtek flow의 평균 교두굴곡량이 더 작은 것으로 측정되었으나 통계적 유의성은 보이지 않았다 (p > 0.05). 2. 수복단면의 SEM 관찰 결과 두 group의 시편 중 각각 2개의 시편에서 와동 내면에 접착이 탈락된 미세간격이 관찰되었다. 3. Filtek flow의 탄성계수간은 7.77 GPa로 Z-250의 17.43 GPa에 비해 절반 이상 낮았으며 중합수축률은 4.41%로 Z-250의 2.23%에 비해 더 큰 것으로 나타났다. 4. 교두굴곡에는 복합레진의 중합수축률 뿐만 아니라 수축응력의 발현에 영향을 주는 탄성계수가 복합적으로 작용함을 알 수 있었다.

삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향 (EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS)

  • 김용희;박재구;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.327-334
    • /
    • 2007
  • 이 연구는 서로 다른 카바이드 버와 다이아몬드 버로 5급 와동을 형성 한 후 SE primer 접착 시스템인 Clearfil SE Bond를 이용한 복합레진 수복 시 버의 종류에 따른 법랑질과 상아질 변연에서의 미세누출 차이를 상호 비교하기 위하여 시행하였다. 4종의 삭제기구를 이용하여 각각 10개의 발거된 대구치의 협면 치경부에 5급 와동을 형성하였다. 1군은 plain-cut carbide fissure bur (no. 245)를 사용한 군, 2군은 cross-cut carbide fissure bur (no. 557)를 사용한 군, 3군은 fine diamond bur (TF-21F: 입자크기 $53\;-\;63\;{\mu}m$)를 사용한 군, 4군은 standard diamond bur (EX-41: 입자크기 $106\;-\;205\;{\mu}m$)를 사용한 군으로 분류하였다. 형성된 와동에 Clearfil SE Bond의 Primer와 Bond를 적용하고 Clearfil AP-X 복합레진을 충전하여 광중합한 후, Sof-Lex disc를 이용하여 마무리와 연마를 시행하였다. 수복된 치아를 2% methylene blue 용액에 24시간 동안 침적시킨 후 각 군의 치아를 협설로 절단하여 광학 입체현미경 하에서 법랑질과 상아질 변연에서의 미세누출 점수를 평가하여 다음과 같은 결과를 얻었다. Clearfil SE Bond와 복합레진을 이용한 5급 와동 수복 시 거친 다이아몬드 버의 사용은 카바이드 버나 미세한 다이아몬드 버에 비해 법랑질과 상아질 변연 모두에서 높은 미세누출을 나타내었다.

상아질 접착제의 미세누출과 변연부 혼화층 (MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES)

  • 조영곤;김영관;안종모
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과 (SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING)

  • 김민정;이미정;유미경;박수정;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.22-30
    • /
    • 2005
  • 수복물의 변연 미세 누출과 마모 개선을 위해 표면 전색제가 개발되었으며 이의 효과에 대해 알아보기 위해, 규격화된 치경부 5급 와동을 25개의 소구치의 협면에 형성하고 Single Bond와 Z-250으로 수복한 뒤, $37^{\circ}C$의 증류수에 7일간 보관한 후 무작위로 5군으로 나누고 다음과 같은 재료로 제조사의 지시에 따라 표면 처리하였다 : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. 그 후 잇솔질 마모시험을 시행하였다. 표면 조도는 잇솔질 전후에 profilometer로 측정되었고 paired t-test와 ANOVA로 비교하였다. 접착면과 표면변화는 전자현미경으로 관찰하였다. 미세누출 평가를 위해 시편은 $2\%$ methylene blue 용액으로 염색한 뒤, 협설로 잘라 제작하였다. 입체현미경을 이용하여 교합면쪽과 치경부쪽 계면에서 미세누출을 관찰하고 Kruskal-Wallis와 Mann-Whitney U test를 이용하여 그 결과를 비교하였다. 표면 조도는 잇솔질 후 수치가 증가하였으나 통계학적으로 유의한 차이를 나타내지는 않았다. 전자 현미경 관찰 결과, 표면 전색제가 접착면에 부분적으로 남아있기도 하였으나 많은 부분에서 떨어져 나간 상태였다. 특히, 미세 틈새가 치경부쪽 변연에서 나타났다. 미세누출 실험에서는 법랑질에서 더 봉쇄효과가 좋았으며 교합면쪽 변연에서 군간에 유의할만한 차이를 나타내었다. 조절군과 Single Bond를 도포한 군에서는 치경부쪽 변연보다 법랑질쪽 변연에서 유의하게 좋은 변연 봉쇄 효과를 나타내었다.

Involvement of TRPA1 in the cinnamaldehyde-induced pulpal blood flow change in the feline dental pulp

  • Kim, Dokyung;Lee, Moon-Hwan;Kim, Sung Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제41권3호
    • /
    • pp.202-209
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the involvement of TRPA1 in the cinnamaldehyde-induced pulpal blood flow (PBF) change in the feline dental pulp. Materials and Methods: Mandibles of eight cats were immobilized and PBF was monitored with a laser Doppler flowmetry at the mandibular canine tooth. To evaluate the effect of cinnamaldehyde on PBF, cinnamaldehyde was injected into the pulp through the lingual artery at a constant rate for 60 seconds. As a control, a mixture of 70% ethanol and 30% dimethyl sulfoxide (DMSO, vehicle) was used. To evaluate the involvement of transient receptor potential ankyrin 1 (TRPA1) in PBF change, AP18, a specific TRPA1 antagonist, was applied into the pulp through the Class V dentinal cavity followed by cinnamaldehyde-administration 3 minutes later. The paired variables of experimental data were statistically analyzed using paired t-test. A p value of less than 0.05 was considered as statistically significant. Results: Administration of cinnamaldehyde (0.5 mg/kg, intra-arterial [i.a.]) induced significant increases in PBF (p < 0.05). While administration of a TRPA1 antagonist, AP18 (2.5 - 3.0 mM, into the dentinal cavity [i.c.]) caused insignificant change of PBF (p > 0.05), administration of cinnamaldehyde (0.5 mg/kg, i.a.) following the application of AP18 (2.5 - 3.0 mM, i.c.) resulted in an attenuation of PBF increase from the control level (p < 0.05). As a result, a TRPA1 antagonist, AP18 effectively inhibited the vasodilative effect of cinnamaldehyde (p < 0.05). Conclusions: The result of the present study provided a functional evidence that TRPA1 is involved in the mechanism of cinnamaldehyde-induced vasodilation in the feline dental pulp.

다양한 복합레진 시스템의 변연 누출도 (MICROLEAKAGE OF VARIOUS COMPOSITE RESIN SYSTEMS)

  • 김인수;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.127-133
    • /
    • 2003
  • The object of this study was to compare the microleakage between various composite resin systems of multistep, one-bottle, and self-etching systems using electrical conductivity. After making class V cavities ($4{\times}3{\times}1.5{\;}mm$ around CEJ), they were bulk filled with three kinds of resins of A3. Teeth were storaged in a saline solution for one day, after then, they were finished and polished using Sof-Lex system. Another stress of thermocycling was made for 500 times from $5^{\circ}{\;}to{\;}55^{\circ}C$ with each dwelling time of 10 seconds. Electrical conductivity (microamphere, $\mu\textrm{A}$) was checked four times: before and after cavity preparation, after filing, after thermocycling. One-way ANOVA and 95% Scheffe Post Hoc test was used for checking any statistical difference among groups. Another 95% Paired Samples T-test was also used for estimating any significant difference within group after cavity filling or thermocycling. The results were as follows: 1 Every specimen showed various range of microleakage after filing. There was, however, no difference between composite resin systems. 2. All composite resin systems showed marked increase in microleakage with a thermocycling (p<0.05), there was, however, no difference between composite resin systems. 3. Although there was no significant difference between groups (p=0.078), one-bottle and self-etching systems seemed to be unstable than multistep system. Within the limits of this study, it was concluded that much more consideration should be needed when using thermally unstable one-bottle and self-etching systems that have multi-advantages from simplified step. More studies will be needed to solve these kinds of problems.

3차원 재구성법을 이용한 수복물의 정량적 미세누출도 측정 (NEW QUANTITATIVE MEASURING TECHNIQUE FOR MICROLEAKAGE OF THE RESTORED TOOTH THROUGH 3D RECONSTRUCTION)

  • 하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.413-422
    • /
    • 2004
  • Established microleakage tests have their own disadvantages. In this study, 3D reconstruction method was tried to overcome these disadvantages. Four types of microleakage tests were used and relationships among them were estimated: penetrated dye volume: marginal adaptability: degree of dye penetration and relative penetrated length to cavity wall. Twenty-four Class V cavities were bulk filled with composite (Esthet X) following surface treatments: N group (no treatment): E group (etching only): T group (etching + Prime & Bond NT). 50% silver nitrate was used as a dye solution after thermocycling ($5^{\circ}C{\;}&{\;}55^{\circ}C$, 1.000 times). Teeth were serially ground with a thickness of 0.2 mm. Volume of dye penetration was estimated from a three-dimensionally reconstructed image with a software (3D-DOCTOR). Percentage of margin without gap was estimated from SEM and degree of dye penetration and the relative length of dye penetration to overall cavity wall were also estimated. ANOVA and Scheffe test for dye volume, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman's rho test for checking of relationships among methods were used. The results were as follows: 1. Dye penetration could be seen from several directions, furthermore, its volumetric estimation was possible. 2. Reverse relationship was found between dye volume and marginal quality (r = -0.881/ p = 0.004). 3. Very low relationship was seen between dye volume and two-dimensional tests (degree of dye penetration and relative length). However, 2D evaluation methods showed high relationship (p = 0.002-0.054) each other. 4. Three times vertical section could be recommended as a 2D test.