• Title/Summary/Keyword: Cavity detection

Search Result 183, Processing Time 0.025 seconds

A Comparison of Active Contour Algorithms in Computer-aided Detection System for Dental Cavity using X-ray Image (X선 영상 기반 치아와동 컴퓨터 보조검출 시스템에서의 동적윤곽 알고리즘 비교)

  • Kim, Dae-han;Heo, Chang-hoe;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1678-1684
    • /
    • 2018
  • Dental caries is one of the most popular oral disease. The aim of automatic dental cavity detection system is helping dentist to make accurate diagnosis. It is very important to separate cavity from the teeth in the detection system. In this paper, We compared two active contour algorithms, Snake and DRLSE(Distance Regularized Level Set Evolution). To improve performance, image is selected ROI(region of interest), then applied bilateral filter, Canny edge. In order to evaluate the algorithms, we applied to 7 tooth phantoms from incisor to molar. Each teeth contains two cavities of different shape. As a result, Snake is faster than DRLSE, but Snake has limitation to compute topology of objects. DRLSE is slower but those of performance is better.

The Endocardial Boundary Detection based on Statistical Charact'eristics of Echocardiographic Image (초음파 영상의 통계적 특성에 근거한 심내벽 윤곽선 검출)

  • Won, Chul-Ho;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.365-372
    • /
    • 1996
  • The researches to acquire diagnostic parameters from ultrasonic images are advanced with the progress of the digital image processing technique. Especially, the detection of endocardial boundary is very important in ultrasonic images, because endocardial boundary is used as a clinical parameter to estimate both the cardiac area and the variation of cardiac volume. Various methods to detect cardiac boundary are proposed, but these are insufficient to detect boundary. In this paper, an algorithm that detects the endocardial boundary, expanding the cavity region from the center using statistical information, is proposed The value of mean and sty:nd, wd deviation in cavity region is lower than those in muscle re- gion. Therefore, if we define the multiplication of mean and standard deviation as homogeneous coefficient, it can lead to conclusion that the pixels with small variation of these coefficleno are cavity region, and extraction of endocardial boundary from cavity region is possible. The proposed method detected endocardial boundary more effectively than edge based or threshold based method and is robuster to noise than radial searching method that has high dependency for center position.

  • PDF

Model Study for Underground Cavity Detection Using S-wave (S파를 이용한 지하공동 탐사의 모형 연구)

  • 서백수
    • Tunnel and Underground Space
    • /
    • v.3 no.2
    • /
    • pp.109-117
    • /
    • 1993
  • The existence and exact location of cavity is very important for the stability of the large underground storage house or building. Numerical method such as finite element method and finite diference methods are widely used because of model's complexity. Preliminary tests such as calculation step test, mesh size test and model size test were tried. Upper shadow zone and lower shadow zone can be calculated from 50% amplitude level of measuring data. From these statistical methods, the calculatied position of cavity coincided nearly with actual position of model testing cavity.

  • PDF

Detection of Methane and Ethane by Continuous-Wave Cavity Ring-Down Spectroscopy Near 1.67 μm

  • Oh, Myoung-Kyu;Lee, Yong-Hoon;Choi, Sung-Chul;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • We report the simple detection method of the small hydrocarbons, methane and ethane, by continuous-wave cavity ring-down spectroscopy near 1.67 ${\mu}m$ using an external cavity diode laser. The absorption lines of methane between 6002.48 $cm^{-1}$ and 6003.37 $cm^{-1}$ and ethane between 5955.65 $cm^{-1}$ and 5956.4 $cm^{-1}$ have been resolved and employed for the gas detection. The largest absorption cross sections were found to be 6.5$\times10^{-20}cm^2$ and 7.4$\times10^{-21}cm^2$ for methane and ethane, respectively, in each spectral range. The minimum detectable absorption limit of our spectrometer was 4.8${\times}10^{-9}cm^{-1}$/$\sqrt{Hz}$, which corresponds to the detection limits of 3 ppb/$\sqrt{Hz}$ and 27 ppb/$\sqrt{Hz}$ for methane and ethane, respectively. The near-IR continuous-wave cavity ring-down spectroscopic detection method of the small hydrocarbons can be applied for medical diagnosis and environmental monitoring as a fast and convenient method.

First step of root canal therapy-access cavity preparation (근관치료의 시작 - 치수강 개방)

  • Song, Minju
    • The Journal of the Korean dental association
    • /
    • v.56 no.10
    • /
    • pp.572-580
    • /
    • 2018
  • Adequate access cavity is the key to achieving endodontic success. The aims of the access cavity can be considered as follows: 1) Creation of a smooth unimpeded pathway for instruments to canal orifices 2) Removal of the entire roof of the pulp chamber in order to inspect the pulp floor, 3) Preservation of natural tooth substance consistent with the above. Recently, contracted endodontic cavities based on minimally invasive endodontics has introduced. This has the benefit of preserving the pericervical dentin more than traditional access cavity with achieving long-term success. However, some studies reported controversial results regarding root canal detection, instrumentation efficacy (noninstrumented canal area, hard tissue debris accumulation, canal transportation, and centering ratio) as well as fracture resistance. Therefore, further studies are required for accepting contracted access cavity, and modified form of traditional and contracted access cavity could be considered.

  • PDF

The Mode of Detection of Helicobacter pylori in Saliva and Subgingival Plaques of Adult Periodontitis Patients (성인형 치주염 환자의 타액 및 치은연하치태에서 Helicobacter pylori의 발현양상)

  • An, Jong-Mo;Na, Myoung-Su;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.4
    • /
    • pp.723-731
    • /
    • 2004
  • Helicobacter pylori(H. pylori) has been associated with the cause of chronic gastritis, peptic ulcers and gastric cancer. Although it may be transmitted through the oral cavity, it is unknown whether the oral cavity acts as a reservoir of H. pylori. The purpose of this study was to investigate the mode of detection of H. pylori in oral cavity of adult periodontitis patients with plaque and periodontal pocket which atmosphere is grown well H. pylori. We analysed detection rate of H. pylori in saliva and subgingival plaques of 17 adult periodontitis patients without symptoms of gastroduodenal disease by nested PCR. Samples tested comprised saliva and subgingival plaques from central incisor, 1st premolar and 1st molar. H. pylori DNA was not identified in saliva from all patients. The detection rate in subgingival plaque from incisors, premolars and molars was 5.9%, 5.9% and 17.7%, respectively. In conclusion, the dental plaque and periodontal pocket (especially, of molars) in adult periodontitis can be favorable reservoir of H. pylori and may be the source of infection and transmission of H. pylori.

Ultrasonographic Evaluation of Experimentally Induced Ascites in Dogs (개에서 실험적으로 유발한 복수증의 초음파 진단)

  • Kim Jong-gyu
    • Journal of Veterinary Clinics
    • /
    • v.12 no.1
    • /
    • pp.839-847
    • /
    • 1995
  • In this study, ultrasonographic evaluations were made after experimentally induced ascites in dogs. Ultrasonographic evaluation allowed to identify the earliest fluid accumulation between the spleen and the left kidney after the administration of 0.9% normal saline at 8 ml/kg into the abdominal cavity in dogs. Ultrasonographic finding were observed in order between the spleen and the left kidney, the liver, the pelvic cavity. It is considered that the most adequate pare f3r the early detection of ascites is between the spleen and the left kidney, and the least amount of detection fluid is 8 ml/kg in dogs.

  • PDF

Helicobacter pylori in the Oral Cavity (구강 내 Helicobacter pylori)

  • Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.2
    • /
    • pp.75-79
    • /
    • 2012
  • Helicobacter pylori(H. pylori) associated with gastritis and gastric cancer is mainly detected dental plaque and saliva in the oral cavity. Most infection is probably acquired in childhood, but the route of transmission is not clear. The oral cavity has been indicated as secondary reservoir of H. pylori, and may therefore be argued in the route of transmission and reinfection of the stomach which follows treatment of H. pylori infection. So this review aimed to discuss about H. pylori in the oral cavity. H. pylori in stomach can appear in the oral cavity by gastroesophageal reflex or vomiting, but infection of stomach and oral cavity is different. Diagnostic methods are serological method, urea breath test, PCR method, urease test, histologic method and so on. Nested PCR recommend for detection of H. pylori in saliva and dental plaque. H. pylori infection in the oral cavity appear variously and is no relation with dental diseases. The antimicrobial mouthrinse recommend in patients with periodontal diseases because of high detection rate fo H. pylori. Thus H. pylori may be considered as the normal oral microflora.

Simple Technique for Measurement of Complex Permittivity and Detection of Small Permittivity Change Using Partially Open Cavity

  • Park, Sangbok;Chung, Young-Seek;Cheon, Changyul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.268-272
    • /
    • 2014
  • This letter presents a measurement methodology of the complex permittivity of liquid using a partially open cavity in narrow band. The partially open cavity (POC) can measure dielectric small changes caused by the temperature variation of the liquid inside the cavity as well. Using the resonance frequency and unloaded quality factor of the proposed POC, the complex permittivity is evaluated. The apertures on the walls of the cavity are designed to circulate the liquid inside to outside of the POC and located at the corner area of the cavity to minimize the disturbance of field distribution at the dominant mode. The results measured by the proposed POC were compared with those by the conventional open-ended probe and Cole-Cole equation. The POC showed better performance in measuring small dielectric constant changes than the open-ended probe.

Improvement of Underground Cavity and Structure Detection Performance Through Machine Learning-based Diffraction Separation of GPR Data (기계학습 기반 회절파 분리 적용을 통한 GPR 탐사 자료의 도로 하부 공동 및 구조물 탐지 성능 향상)

  • Sooyoon Kim;Joongmoo Byun
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.4
    • /
    • pp.171-184
    • /
    • 2023
  • Machine learning (ML)-based cavity detection using a large amount of survey data obtained from vehicle-mounted ground penetrating radar (GPR) has been actively studied to identify underground cavities. However, only simple image processing techniques have been used for preprocessing the ML input, and many conventional seismic and GPR data processing techniques, which have been used for decades, have not been fully exploited. In this study, based on the idea that a cavity can be identified using diffraction, we applied ML-based diffraction separation to GPR data to increase the accuracy of cavity detection using the YOLO v5 model. The original ML-based seismic diffraction separation technique was modified, and the separated diffraction image was used as the input to train the cavity detection model. The performance of the proposed method was verified using public GPR data released by the Seoul Metropolitan Government. Underground cavities and objects were more accurately detected using separated diffraction images. In the future, the proposed method can be useful in various fields in which GPR surveys are used.