• 제목/요약/키워드: Cavity Wall

검색결과 547건 처리시간 0.026초

수압작용에 따른 지반내 공동생성 및 수리거동에 대한 개별요소해석 (Distinct element simulation of cavity development and fluid behavior caused by fluid injection)

  • 전제성;김기영;김재홍;이종욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.676-679
    • /
    • 2008
  • Numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. After generation of initial particles and wall elements, confining stress was applied by servo-control method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell. Fluid was injected as 7-step into the assembly in the x-direction from the inlet located at the center of the left boundary under confining stress condition, 0.1MPa and 0.5MPa, respectively. For each simulation, movement of particles, flow rate, fluid velocity, pressure history, wall stress including cavity initiation and propagation by interaction of flulid-paricles were analyzed.

  • PDF

공동 상류 경사 분사를 이용한 초음속 연소기의 실험적 연구, Part 1 : OH-PLIF 측정 (Experimental Study on Supersonic Combustor using Inclined Fuel Injection with the Cavity, Part 1: OH-PLIF Measurement)

  • 정은주;정인석
    • 한국연소학회지
    • /
    • 제12권1호
    • /
    • pp.11-20
    • /
    • 2007
  • The supersonic combustion experiments are carried out using T3 free-piston shock tunnel. Different shock tube fill pressures have various inflow conditions. $15^{\circ}$ inclined hydrogen fuel injection is located before the cavity. Oblique shock is generated from the cavity and reflects off the top and bottom wall. For non-reacting flow, fuel makes the shear layer thicker above the cavity therefore, the shock is generated just before the trailing edge. This research has self-ignition in the combustor. For reacting flow, as the equivalence ratio increases, flame starts to generate near the injector or occur in the recirculation zone before the injector. High fuel injection sustains the jet shape in the cross flow and air can mix with fuel along the shear layer. Therefore, two flame layers find above the cavity for high equivalence ratio.

  • PDF

와동면(窩洞面)의 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A SCANNING ELECTRON MICROSCOPIC STUDY OF CAVITY WALL)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 1985
  • The purpose of this study was to observe the facial, lingual and gingival walls of the cavity walls with various kinds of cutting tools. Class II cavities were prepared in newly extracted sound humen mandibular 1st left premolars, and observed in Sanning electron microscope. Diamond point (#201) and Tungsten Carbide burs (#170L) were used in ultra high speed handpieces (rpm 200000), and Tungsten Carbide bur (#702) and Steel bur (#560) were used in conventional handpieces (rpm 6000). All cavities were prepared under water spray, except for some which were finished with a dry abrasive stone (#57). Some cavities were finished with chisels (#41, 42, 83). The following results were obtained. 1. The cavity walls prepared with Diamond point were rougher than the cavity walls with Carbide burs and Steel burs. 2. The chisels were produced the smoothest surface. 3. The cavity walls which were prepared with cutting blades rotated toward enamel surface from outside, were smoother than cavity walls which were prepared with cutting blades rotated toward outside from the enamel surface.

  • PDF

Cavity내의 단일 열원에 대한 최적 열적설계 (Optimal Thermal Design of a Single Heat Source in a Cavity)

  • 예용택;추홍록;김현우
    • 태양에너지
    • /
    • 제19권1호
    • /
    • pp.77-86
    • /
    • 1999
  • The optimal thermal design of a single heat source on one wall of a vertical open top cavity was studied experimentally. The temperature and flow fields in the cavity were visualized. The objectives of this study is to obtain the best location of the single heat source and to examine the effects of heat source protrusion, substrate thermal conductivity and cavity aspect ratio on the natural convection cooling due to a single heat source. As the results, the cooling effect for the copper substrate is superior to that of the epoxy-resin substrate and is improved with increasing cavity width. For the epoxy-resin substrate of lower conductivity, the protrusion of the heaters plays a role in decreasing the cooling effect. The best location was the mid-height of the substrate.

  • PDF

금전장관 수복물을 통한 치수강 개방이 금전장관 수복물의 미세변연누출에 미치는 영향 (THE EFFECT OF THE ENDODONTIC ACCESS CAVITY ON THE MARGINAL LEAKAGE OF CROWNS)

  • 김의성;정진호;김용근
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.389-393
    • /
    • 2002
  • The marginal integrity of the crown can be broken during endodontic access cavity preparation due to the vibration of burs. Therefore, the purpose of this study was to evaluate the effect of endodontic access cavity preparation on the marginal leakage of full veneer gold crowns. 24 intact molars were mounted in acrylic resin blocks and prepared for crowns by a restorative dentist and crowns were cast with gold alloy. 20 Crowns were cemented with glass ionomer cement and 2 crowns were not cemented for positive control. 200 thermo-cycles from 5$^{\circ}C$ to 5$0^{\circ}C$ with a travel time of 20s were completed. Then samples were randomly divided into 2 experimental groups of 9 each. Endodontic access preparation and zinc-oxide eugenol temporary fillings were done in Group 1. Teeth in Group 2 were not treated. Samples were coated with 2 layers of nail varnish and were immersed in 1% methylene blue dye for 20 hrs. Endodontic access was prepared in 2 samples, which were coated with nail varnish on all surfaces for negative control. After washing in running water gold crowns were cut with a #330 bur. Four buccolingual sections, 2 mm apart, were cut from the central section of each tooth and were examined and scored under the microscope for dye leakage. Score 1: leakage to the cervical 1/3 of the axial wall, Score 2: leakage to the middle 1/3 of the axial wall, Score 3: leakage to the coronal 1/3 of the axial wall, Score 4: leakage to the occlusal surface. The median value for Group 1 is 4 and for Group 2 is 2. The result of this study showed that samples in Group 1 leaked more than those in Group 2. This finding was significant(P<0.001).

Association of Endometrial Polyps with Membranous Adhesions in Uterine Cavity

  • Lee, Yoon-Jung;Cha, Dong-Hyun;Kim, Ji-Young;Cho, Jung-Hyun;Lee, Gun-Ho
    • 한국발생생물학회지:발생과생식
    • /
    • 제15권4호
    • /
    • pp.291-299
    • /
    • 2011
  • The membranous adhesions could induce implantation failure despite transplantation of high quality of embryo. Clinically, of the patients who have membranous filmy adhesions, endometrial polyps have been found in not infrequently. Thus this study was tried to evaluate the features of endometrial polyps and the effect of endometrial polyps on formation and extents of membranous adhesions in uterine cavity of infertile patients under hysteroscopy. A retrospective study was conducted on 34 infertile patients who were diagnosed as endometrial polyps with membranous adhesions during hysteroscopy from July 2008 to July 2011. Number, size, location and morophologic type of endometrial polyps were investigated. If needed, methylene blue solution was instillated to endometrial cavity to identify membranous adhesions. Then, associations between membranous adhesions with features of endometrial polyps were evaluated. Mean size of endometrial polyp was $1.6{\pm}0.6$ cm, the bigger of endometrial polyps was, the larger of extents of membranous adhesions. (p<0.05). Endometrial polyps were locate evenly in endometrial cavity as follows: anterior uterine wall, 39.1%; posterior uterine wall, 34.8%; lateral uterine wall, 26.1%; upper: 29.4%, middle: 32.4%, lower segment, 35.3%. Mean number of endometrial polyps was $2.26{\pm}1.3$. The pedunculated type was 37.7% and sessile type was 32.4%. There was no statistically significant association of location, number and morphologic type of endometrial polyps with membranous adhesions. In conclusion, hysteroscopy before in vitro fertilization on infertile patients was worthy because of removing of endometrial polyps and membranous adhesions.

2차원 캐비티 유동에서 다중 정상 해에 관한 연구 (Multiple steady state solutions in a two dimensional cavity flow)

  • 조지룡;홍상표;김근오;김윤택
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.127-138
    • /
    • 1999
  • 본 연구에서는 2 차원 캐비티 유동에서 경계조건 부여 방법의 차이에 따른 유체유동의 이력이 최종적인 정상상태에 미치는 효과를 수치실험을 통하여 관찰하였다. 그 결과 유동의 Reynolds 수가 작은 경우는 유동장이 가지는 이력이 시간의 경과와 함께 소멸하여 하나의 정상유동 상태를 가지는데 반하여, 큰 Reynolds 수에서는 유동장 이력이 소멸하지 않고 유지됨으로 인하여 다수의 정상유동 형태가 나타남이 확인이 되었다. 엄밀한 이론적 해석은 현재 이루워지지 않았으나 유체 운동량의 증가에 따라 Navier-Stokes 방정식의 비선형성이 영향을 미치고 있다고 여겨진다.

  • PDF

보조공동을 이용한 초음속 공동내부의 압력진동 저감에 관한 연구 (A Study on the Reduction of Supersonic Cavity Pressure Oscillations Using a Sub-Cavity System)

  • 신춘식;정준창;;김희동
    • 한국추진공학회지
    • /
    • 제13권5호
    • /
    • pp.41-47
    • /
    • 2009
  • 2차원 초음속 공동유동에서 발생하는 압력진동을 제어하기 위한 목적으로, 본 연구에서는 수치해석적 연구를 수행하였다. 본 계산에서는 압력진동을 제어하기 위하여 보조공동의 형상을 변화시켰으며, 유동의 마하수를 1.50, 1.83 그리고 2.50로 변화시켰다. 그 결과, 보조공동은 압력진동을 상당히 감소시켰으며, 압력진동의 제어효과는 유동의 마하수와 보조공동의 상세형상에 크게 의존함을 알았다.

새로운 수동제어소자인 공동을 이용한 마찰력과 열전달 감소에 관한 연구 (Cavity as a New Passive Device for Reduction of Skin Friction and Heat Transfer)

  • 한성현;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.463-466
    • /
    • 2002
  • In order to examine the possibility of using a cavity as a passive device for reduction of skin friction and heat transfer, an intensive parametric study over a broad range of the cavity depth and length at different Reynolds numbers is performed for both laminar and turbulent boundary layers in the present study. Direct and large eddy simulation techniques are used for turbulent boundary layers at low and moderate Reynolds numbers, respectively. for both laminar and turbulent boundary layers over a cavity, a flow oscillation occurs due to the shear layer instability when the cavity depth and length are sufficiently large and it plays an important role in the determination of drag and heat-transfer increase or decrease. For a cavity sufficiently small to suppress the flow oscillation, both the total drag and heat transfer are reduced. Therefore, the applicability of a cavity as a passive device for reduction of drag and heat transfer is fully confirmed in the present study. Scaling based on the wall shear rate of the incoming boundary layer is also proposed and it is found to be valid in steady flow over a cavity.

  • PDF

An Analytic Study on Laminar Film Condensation along the Interior Surface of a Cave-Shaped Cavity of a Flat Plate Heat Pipe

  • Lee, Jin-Sung;Kim, Tae-Gyu;Park, Tae-Sang;Kim, Choong-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.966-974
    • /
    • 2002
  • An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ$\_$crit/=3∼7%, Ψ$\_$crit/=0.5∼1.3% respectively, in the range of heat flux q"=5∼90kW/㎡.