• Title/Summary/Keyword: Cavity Temperature Sensor

Search Result 46, Processing Time 0.025 seconds

Designing and Manufacturing Technology of Sensor Node for Machine Tools (공작기계용 센서노드 설계 및 제작기술)

  • Jang, D.Y.;Kwon, O.S.;Park, M.J.;Kim, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.569-576
    • /
    • 2014
  • Sensor node means a device to include sensor, amplifier, and data acquisition (DAQ) equipment. The sensor converts physical signals to electric signals and weak signals from the sensor can be amplified through the amplifier. DAQ equipment converts analog signal to digital signal and collects converted digital signal. Since the sensor node is sensitive to the environment so that selection of mounting position and fixture design of sensor are applied differently depending on the characteristics of a target. This study is about designing and manufacturing sensor node to be used in a machine tool. The environment of machine tool is very severe due to noise, temperature fluctuation, and dust, etc. Hence, the sensor and amplifier must be designed and manufactured by considering the environmental issues. The designed and manufactured sensor node was tested for the reliability and effectiveness of the developed sensor nodes in the study.

Temperature Compensation of NDIR CO2 Gas Sensor (비분산 적외선 이산화탄소 센서의 온도 보상)

  • Park, Jung-Min;Park, Young-Hwan;Yi, Seung-Hwan;Park, Jeong-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.81-82
    • /
    • 2005
  • 본 논문에서는 두 개의 오목 반사경으로 형성된 광 공동 구조의 비문산 적외선 (NDIR) 가스센서를 제작하였다. 증폭비는 18,000 배, 램프 off 시간은 3초로 일정하게 하고 펄스 modulation 시간을 200ms에서 600ms까지 변화시켰을 때. 300ms에서 가장 효율적인 출력신호를 확보할 수 있었다. 그리고 $5^{\circ}C$에서 $45^{\circ}C$까지 $10^{\circ}C$ 간격으로 온도를 변화시키면서 이산화탄소의 농도를 0ppm에서 2000ppm까지 증가시켰다. 이때, 약 400mV의 전압변화가 있었다. 온도가 상승함에 따라 0ppm에서의 출력전압은 감소하는 양상을 나타내었다. 또한 온도변화 대비 출력특성과의 상관성 해석을 통하여 온도 보상 방법을 고안하였으며, 본 연구에서 제작한 센서모듈의 응답시간은 약 30초였다.

  • PDF

Linear Structural Analysis of Standard Plastic Tensile Specimen with Residual Stress Induced by Injection Molding (사출성형과정의 잔류응력을 고려한 표준인장시편의 선형구조해석)

  • Lee D.M.;Han B.K.;Lee Sung-Hee
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.579-580
    • /
    • 2006
  • In this study, an injection mold of tensile test specimen was manufactured by international standard. Pressure and temperature in the cavity of the injection mold was measured by sensors. Simulation of injection molding process was performed with the same condition of experiment and linear structural tensile analysis was also performed with the initial condition of the residual stress induced by injection molding analysis. Normalized elastic coefficient of tensile test was compared with that of structural analysis. It was shown that the residual stress induced by injection molding has an effect on both the experiment of tensile test and linear structural analysis.

  • PDF

Fabrication and Temperature Compensation of Silicon Piezoresistive Absolute Pressure Sensor for Gas Leakage Alarm System (가스누출 감지용 실리콘 압저항형 절대압센서의 제조 및 온도보상)

  • Son, Seung-Hyun;Kim, Woo-Jeong;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.171-178
    • /
    • 1998
  • Silicon piezoresistive absolute pressure sensor for gas leakage alarm system was developed. This sensor must operate normally in the range of $0{\sim}600\;mmH_{2}O$ pressure, and $0{\sim}100^{\circ}C$ temperature. To make the most of this sensor for gas leakage alarm system, gas must not leak from the sensor itself when the diaphragm of the sensor fractures. Thus, the sealed diaphragm cavity was anodically bonded to pyrex 7740 glass under the condition of $10^{-4}$ torr, at $400^{\circ}C$. The sensitivity of developed sensor was $4.06{\mu}V/VmmH_{2}O$ for $600\;mmH_{2}O$ full-scale pressure range. And temperature compensation method of this sensor is to change bridge-in put-voltage linearly in proportion to the temperature variation by using diode(PXIN4001) or Al thin film resistor. By these methods the temperature effect in the range of $0{\sim}100^{\circ}C$ was compensated over 80 % for offset drift, 95 % for sensitivity.

  • PDF

Fiber Bragg Grating Temperature Sensor by the Wavelength Tuning Using the Temperature Dependence of VCSEL (빅셀(VCSEL)의 온도 의존성을 이용한 파장 가변 형 광섬유 격자 온도센서)

  • Lee, Chung-Ki;Kim, Sung-Moon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.241-246
    • /
    • 2018
  • In this paper, a low-cost optical temperature sensor is implemented, using a fiber Bragg grating (FBG) as the temperature probe and a low-cost VCSEL with temperature-dependent output wavelength as the light source. To analyze the wavelength of the reflected light from the FBG, an interrogation was applied using a method of referring to the internal temperature according to the output wavelength of the VCSEL. When the temperature of the VCSEL was adjusted from 14 to $52.2^{\circ}C$, the output wavelength varied from 1519.90 to 1524.25 nm. The degree of wavelength tuning according to temperature was $0.114nm/^{\circ}C$. The variable wavelength repeatability error according to temperature was ${\pm}0.003nm$, and the temperature measurement error was ${\pm}0.18^{\circ}C$. As a result of measuring the temperatures from 22.3 to $194.2^{\circ}C$, the value of the internal temperature change of the light source according to the applied temperature ${\Delta}T$ was $0.146^{\circ}C/{\Delta}T$, the change in reflected wavelength of the temperature probe according to applied temperature ${\Delta}T$ was measured at $16.64pm/^{\circ}C$. and the temperature measurement error of the sensor was ${\pm}1^{\circ}C$.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

Feasibility Study of the Application of Infinite Tube Probe in High Temperature Environment (고온 환경에서 무한 튜브 검출기의 적용에 관한 타당성 연구)

  • Kim, Hyeonjun;Ryu, Chulsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.108-119
    • /
    • 2020
  • Dynamic pressure sensor used in liquid rocket engine combustor and gas turbine is recess-mounted usually because it should work in high temperature environment. Although recess-mounted method can protect it from combustion gas in high temperature, tube resonance occurs in a tube-cavity system. To reduce it, the infinite tube probe(ITP) was introduced in this study. The ITP model suggested in previous literature was validated with experimental data and frequency response characteristics were analyzed. Guidelines for designing the ITP were suggested as frequency response profiles varied with geometric information and physical properties using this model.

Development of Real-Time Condition Diagnosis System Using LabVIEW for Lens Injection Molding Process (LabVIEW 를 활용한 실시간 렌즈 사출성형 공정상태 진단 시스템 개발)

  • Na, Cho Rok;Nam, Jung Soo;Song, Jun Yeob;Ha, Tae Ho;Kim, Hong Seok;Lee, Sang Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.23-29
    • /
    • 2016
  • In this paper, a real-time condition diagnosis system for the lens injection molding process is developed through the use of LabVIEW. The built-in-sensor (BIS) mold, which has pressure and temperature sensors in their cavities, is used to capture real-time signals. The measured pressure and temperature signals are processed to obtain features such as maximum cavity pressure, holding pressure and maximum temperature by the feature extraction algorithm. Using those features, an injection molding condition diagnosis model is established based on a response surface methodology (RSM). In the real-time system using LabVIEW, the front panels of the data loading and setting, feature extraction and condition diagnosis are realized. The developed system is applied in a real industrial site, and a series of injection molding experiments are conducted. Experimental results show that the average real-time condition diagnosis rate is 96%, and applicability and validity of the developed real-time system are verified.

Development of the Insufflator for Endoscopic Surgery using the Fluidic System in Printed Circuit Board (유공압 부품이 내장된 인쇄회로기판을 활용한 내시경 수술용 기복기의 개발)

  • Lee, Hee-Nam;Kim, In-Young;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • The insufflators in endoscopic surgery supply carbon dioxide to make the air-filled cavity in the abdomen. It contains many kinds of pneumatic and electronic parts and they are connected with the air tubes and electrical wires. The printed circuit boards (PCB) perform wiring, holding and cooling tasks in electronic systems. In this study, the PCB is used as the air channel for insufflators to decrease the cost, volume, and the malfunction according to aging of the device. Three layers of PCB made of FR4 are combined with prepreg as adhesive which has the internal airway channel according to the design. By mounting the pressure sensors and valves, the PCB based fluidic system is implemented. After calibration of flow sensor, the flow rate of the gas also can be measured. The climate test, temperature test, and biocompatibility test showed this idea can be used in insufflators for laparoscopic surgery.

Technology of Mold Design and Manufacturing for Vacuum-Assisted Thermoforming Mold in Insert Film Injection Molding (INSERT FlLM 사출성형용 진공열성형 금형설계 및 제작기술)

  • Lee, S.H.;Ko, Y.B.;Lee, J.W.
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.69-73
    • /
    • 2008
  • 본 연구에서는 고분자 플라스틱 부품의 친환경 외장성형공법인 Insert Film 사출성형공법중 첫 번째 공정인 진공성형공정에서 진공금형의 표면온도 균일화 기술에 대해 연구를 수행하였다. 진공금형의 온도분포 균일화를 위한 금형설계 및 설계된 금형에 대한 온도분포 평가를 위한 ANSYS를 이용한 유한요소열해석을 수행하였으며, 이때 정상상태 및 과도상태를 함께 평가하였다. 설계 결과를 바탕으로 금형을 제작하였으며, 생산성을 고려하여 4캐비티로 제작된 금형에 대해 금형표면의 온도분포 평가실험을 수행하였다. 또한 금형내 캐비티 온도센서 및 제어시스템을 설치하여 진공금형표면 온도분포가 항상 일정하게 유지될 수 있도록 금형시스템을 개발하였다. 결과적으로 일정한 온도범위의 금형표면온도제어가 가능하였다.

  • PDF