• 제목/요약/키워드: Cathodic Protection

검색결과 240건 처리시간 0.021초

Corrosion protection behavior of AZ31 magnesium alloy with cathodic electrophoretic coating pretreated by cerium based conversion coatings at various pH

  • Fazal, Basit Raza;Phuong, Nguyen Van;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.268-268
    • /
    • 2015
  • The corrosion protection behavior of AZ31 magnesium alloy (Mg alloy) with cathodic electrophoretic coating (E-coating) pretreated by cerium-based conversion coatings at various pH was investigated in this study. Cerium-based conversion coatings (CeCCs) were deposited on AZ31 Mg alloy by immersion treatment in the nitrate-based cerium salt solution. The morphology and composition of the CeCCs were analyzed using scanning electron microscopy and energy dispersive X-ray spectroscopy. The corrosion properties of the AZ31 Mg alloy pretreated with cerium coating and subsequently E-coated were studied during salt-spray testing. The surface morphologies of the E-coated Mg alloy were examined in detail after different testing times using digital photography. It was found that the protective properties of the E-coating on AZ31 Mg alloy generated are heavily dependent upon the CeCC factors such as treatment time, coating thickness and pH of the solution.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

해양금속구조물의 전기방식을 위한 고효율 정류기 개발 (The Development of the High-efficiency Rectifier on Marine Metallic Structures)

  • 하태현;김대경;배정효;이현구;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3130-3132
    • /
    • 2000
  • The Cathodic Protection system which is usually applied to marine metallic structures in domestic is Sacrificial Anode Method. In general, low efficiency rectifiers are using in the field of Cathodic Protection. These rectifiers are not only low efficiency but also manual type which is not able to control remotely. In this paper we describe the high efficiency rectifier used the high speed switching method for optimum corrosion control of marine metallic structures.

  • PDF

백필 상태에 따른 마그네슘 양극의 가속수명시험 특성에 관한 연구 (Chracterization of Ng alloy with dry and wet backfill under accelerated C.P. condition)

  • 박경화;김대경;배정효;하태현;이현구;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1933-1935
    • /
    • 2005
  • In this investigation, the electrochemical behaviour of magnesium alloy anode was studied by using electrochemical methods and the performance of magnesium alloy anode was observed with dry and wet backfill under accelerated cathodic protection. This paper reports the data collected at the laboratory and field sites over one year exposure of magnesium anode under cathodic protection donditions.

  • PDF

천연해수 중 음극방식 응용 원리에 의해 제작한 Mg(OH)2 코팅막의 밀착성 및 내식성 (Adhesion and Corrosion Resistance of Mg(OH)2 Films Prepared by Application Principle of Cathodic Protection in Natural Seawater)

  • 이승효;김혜민;임경민;김병구;이명훈
    • 한국표면공학회지
    • /
    • 제46권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Cathodic current on a metal tends to increase the $OH^-$ neighboring to the metal surface, especially during electro-deposition in seawater. The increased pH at metal/seawater interface results in precipitation of brucite crystal structure-$Mg(OH)_2$ as following formula; $Mg^{2+}+2OH^-{\rightarrow}Mg(OH)_2$, that is typical mechanism of the main calcareous deposits-compound in electro deposited coating films. In this study, the effects of anode and current density on deposition rate, composition structure and morphology of the deposited films were systematically investigated by scanning electron microscopy(SEM) and x-ray diffraction(XRD), respectively in order to overcome the problems such as deposition rate and a weak adhesion between deposit film and metal surface. The adhesion and corrosion resistance of the coating films were also evaluated by anodic polarization test. The electro-deposited film formed by using AZ31-Mg anode had the most appropriate physical properties. Weight gain of electro-deposit films increased with increasing cathodic current. Electro-deposit prepared at $5A/cm^2$ current density shows better adhesion than that formed at $8{\sim}10A/cm^2$.

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가 (Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment)

  • 이해승;조규환;박동천
    • 한국건축시공학회지
    • /
    • 제14권5호
    • /
    • pp.397-405
    • /
    • 2014
  • 극한 염해환경에서 철근보강 지오폴리머 시험체의 외부전원법 전기방식 특성을 평가를 위하여 일련의 촉진실험을 실시하였다. 동시에 같은 조건의 보통 시멘트 콘크리트도 제조하여 비교 검토하였다. 환경조건은 침지대, 간만대, 그리고 크랙을 상정하였다. 지오폴리머는 밀실한 재료적 특성에 기인한 열화인자 침투 저항 증대에 의해 자연전위 뿐만 아니라 촉진 종료 후의 부식면적에서도 상당히 우수한 방식 성능이 있는 것으로 밝혀졌으며 향후 제작 양생 등의 문제를 개선함으로써 해양구조물로써의 활용이 다양해질 것으로 기대된다.

강판상에 굴 패각을 이용한 탄산칼슘 피막의 형성 (Formation of Calcareous Deposit on Steel Plate by using Waste Oyster Shell)

  • 김범수;권재성;김연원;이명훈;양정현
    • 한국표면공학회지
    • /
    • 제50권6호
    • /
    • pp.531-535
    • /
    • 2017
  • Enormous amount of waste oyster-shell (OS) has a major disposal problem in coastal regions. OSs have attracted much attention for recycling, because these are mainly composed of calcium carbonate with rare impurities. In this study, we demonstrate the calcareous deposit films on steel plate by using OSs on the basic of cathodic protection technique. The composition of the OSs was analyzed by wavelength dispersive X-ray fluorescence spectrometer. Carbon dioxide gas was pumped into distilled water to make carbonic acid solution for dissolution of OS. The calcareous deposit was characterized by second electron microscope (SEM), energy dispersive X-ray analysis (EDX) and X-ray diffraction. Corrosion rates were estimated by measurements of anodic polarization and immersion test. It is confirmed that calcareous deposits on steel plate are formed under all condition of cathodic protection by using waste OS from the SEM and EDX results. Calcareous deposits on steel by OS provide good corrosion resistance by acting as a barrier to oxygen supply to the steel surface.