• Title/Summary/Keyword: Cathode ray tube

Search Result 100, Processing Time 0.025 seconds

Exposure Filter Design for Wide Angle CRT (CRT 편향각 증가를 위한 노광필터 설계)

  • Kim, Ryo-Hyang;Lee, Tae-Yong;Choi, Sie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.14-20
    • /
    • 2008
  • In recent days, a wide angle for slim depth in CRT(Cathode ray tube) is required to meet other rapidly growing slim FPD such as LCD and PDP. However, in making the CRT with a wide angle screen, problems, such as a difficulty in forming black matrix, and excessive formation of black matrix, can be occurred. In this work, we designed a new exposure filter systm to avoid these problems for a wide angle CRT. We changed the design concept from a filter-to-Panel method to a Panel-to-fater control method, which can control the Black Matrix to easily satisfy the user's request. This study suggests new filter design method for a wide angle CRT which has good screen qualify.

Quantitative Analysis of Phosphors Decay Characteristic for Flicker-free Display System Design (플리커 저감 디스플레이 시스템 설계를 위한 인광체 잔광 특성의 정량적 해석)

  • Kwon, Yong-Dae;Choi, Duk-Kyu;Han, Chan-Ho;Lee, Gwang-Soon;Kim, Eun-Su;Lee, Sang-Hoon;Sohng, Kyu-Ik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.6
    • /
    • pp.9-16
    • /
    • 2000
  • The perception of flicker on the computer display devices depends upon the temporal waveform of the phosphor decay characteristic, the frame rate, and the display size. The lowest frequency at which flicker is not perceived is called the critical fusion frequency or critical frequency. Critical fusion frequency is evaluated by the display illuminance and the modulation (m) defined as the ratio of the amplitude of first harmonic frequency to the DC of the waveform. In this paper, we analyze the relationship bet ween the critical fusion frequency, relating to the decay characteristic of the phosphors and luminance on the monitor, and the frame frequency. Also under considering the viewing angle, we presented the frame frequency that is less sensitive to the full size of the display device.

  • PDF

Trend on Recycling Technologies for Display Wastes analysed by the Patents and Literature Review (특허(特許)와 논문(論文)으로 본 폐(廢) 디스플레이 재활용(再活用) 기술(技術) 동향(動向))

  • Lee, Sung-Kyu;Lee, Chan-Gi;Hong, Hyun-Seon;Cho, Young-Ju;Cho, Bong-Gyoo
    • Resources Recycling
    • /
    • v.21 no.3
    • /
    • pp.65-73
    • /
    • 2012
  • There are several kinds of displays such as liquid crystal display (LCD), cathode ray tube (CRT), plasma display panel(PDP), light emitting diode (LED), organic light emitting diode (OLED), etc. Nowadays, recycling technologies of waste displays have been widely studied from economy and efficiency points of view. In this paper, patents and literature on the recycling technologies of the waste displays have been comprehensively analyzed. The search was limited to the open patents of USA (US), European Union (EU), Japan (JP), and Korea (KR) and SCI journals published from 1980 to 2011. Patents and journals were systematically compiled and collected using key-words search and filtered by pre-set filtering criteria. The trends of the patents and journals were thus analyzed according to the years, countries, companies, and technologies.

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

Evolution of spatial light modulator for high-definition digital holography

  • Choi, Ji Hun;Pi, Jae-Eun;Hwang, Chi-Young;Yang, Jong-Heon;Kim, Yong-Hae;Kim, Gi Heon;Kim, Hee-Ok;Choi, Kyunghee;Kim, Jinwoong;Hwang, Chi-Sun
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.23-31
    • /
    • 2019
  • Since the late 20th century, there has been rapid development in the display industry. Only 30 years ago, we used big cathode ray tube displays with poor resolution, but now most people use televisions or smartphones with very high-quality displays. People now want images that are more realistic, beyond the two-dimensional images that exist on the flat screen, and digital holography-one of the next-generation displaysis expected to meet that need. The most important parameter that determines the performance of a digital hologram is the pixel pitch. The smaller the pixel pitch, the higher the level of hologram implementation possible. In this study, we fabricated the world-smallest $3-{\mu}m$-pixel-pitch holographic backplane based on the spatial light modulator technology. This panel could display images with a viewing angle of more than $10^{\circ}$. Furthermore, a comparative study was conducted on the fabrication processes and the corresponding holographic results from the large to the small pixel-pitch panels.

Structure-Property Relationship of PVA-SbQ Water Soluble Photosensitive Polymer and its Application to Screening Process of Color Monitor (PVA-SbQ 수용성 감광성 고분자의 구조와 감도관계 및 칼라 수상관 스크린 공정에의 응용)

  • Park, Lee Soon;Han, Yoon Soo;Kim, Bong Chul
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.379-386
    • /
    • 1996
  • Photosensitive compound, 1-methyl-4-[2-(4-diethylacetylphenyl)ethenyl] pridinium methosulfate(SbQ-A salt), was synthesized from dimethyl sulfate, terephthalaldehyde mono-(diethylacetal) and 4-picoline. SbQ-A salts were reacted with poly(vinyl alcohol)s, (PVA) in aqueous solution with phosphoric acid as catalyst to give photosensitive PVA-SbQ with different SbQ content and molecular weight. Relative photosensitivity of PVA-SbQ was determined by gray scale(GS) method. The rotative sensitivity of PVA-SbQ increased with increasing amount of bound SbQ in the case of high molecular weight(MW=77,000-79,000g/mol) as substrate and decreased with decreasing molecular weight of PVA with about constant(1.3mol%) amount of bound SbQ. The most sensitive polymer was obtained when SbQ group content in PVA-SbQ reached about 2.63mol% in the case of high molecular weight(77,000-79,000g/mol) PVA. This sample showed 90 times greater sensitivity than dichromated PVA as reference photosensitive system. PVA-SbQ photosensitive polymer synthesized was applied to the photolithographic screening process of phosphor on the panel of cathode ray tube(CRT). Phosphor slurry was made with PVA-SbQ, phosphor, a small amount of surfactant and other additives using water as medium. The slurry was coated onto panel, dried by heater, exposed to UV light and then developed by distilled water. When a small amount of cationic surfactant such as cetyltrimethylammonium chloride was used in the slurry formulation, the sharpness of phosphor pattern was equal to or better than that of dichromated PVA photosensitive polymer system used currently.

  • PDF

Study On The Signal Radar Plan Position Indicator Scope Of The Data Expressed Scanning System Implemented As An Sticking Image On LCD Display (Plan Position Indicator Scope 주사방식의 Radar 영상신호를 LCD Display에 잔상영상으로 데이터 표출 구현에 관한 연구)

  • Shin, Hyun Jong;Yu, Hyeung Keun
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.94-101
    • /
    • 2015
  • The display device is an important video information communication system device to connect between human and device. it transfers the information as characters, shapes, images and pattern to enable recognizing by eyes. Theres absolutely needs some key functions and role to quickly display informations. It can analyse a information through a PPI Scope of a cathode-ray tube(CRT) displays information which can perform a role. this research proposed a radar device to display informations as received signal. The radar display researches can apply to fixed function graphics pipeline algorithms of the large capacity type through a vertical blanking interval and buffer swap of display unit. Also, it can be possible to apply to performed algorithms to FPGA logic without high-performance graphics processing unit GPU through synchronization which can implement a display system. In this paper, we improved the affordability and reliability through proposed research. 이So, we have studied the radar display unit which can change a flat display from radar display of CRT radar display.

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

A Study on the I-V characteristics of a Organic Light-Emitting Diode (유기발광소자(OLED)의 전압-전류 특성에 대한 연구)

  • Lee Jung-Ho;Chae Kyu_Su;Kim Min-Nyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.159-162
    • /
    • 2005
  • 전자빔을 이용하던 CRT(Cathode Ray Tube) 모니터에서 픽셀단위의 LCD(Liquid Crystal Display) 디스플레이 사용으로 휴대용 정보처리 장치들은 급속한 발전을 이루게 되었다. 기존의 CRT 모니터에서 전자빔을 사용하던 방식에서 픽셀(Pixel) 단위의 후면발광 디스플레이를 만들면서 CRT 모니터보다 빠른 응답특성을 나타내며 저 전력일 뿐만 아니라 디스플레이의 두께도 줄일 수 있게 되었다. 휴대가 가능한 디스플레이의 발전으로 노트북이나 PDA와 같은 실시간 정보를 활용 및 처리 할 수 있는 방법들을 제시할 수 있었지만 원활한 활용을 위해 더 적은 전력을 사용하는 방법들이 제시되어야 했다. 이에 따라 저 전력 소모, 빠른 응답특성, 넓은 시야각 그리고 경량화가 가능한 디스플레이가 되기 위한 새로운 디스플레이가 선을 보이게 되었다. 현재 차세대 디스플레이로 각광을 받고 있는 디스플레이 소자로는 OLED(Organic Light Emitting Diode)가 있다 이는 LCD 디스플레이가 가지고 있는 단점을 보완하여 우선적으로 높은 색도가 가능하며 후면발광을 사용하지 않고 자체 발광을 하기 때문에 저 전력 소모가 현실화되었다. 또한 디스플레이의 유동성이 가능하여 휘어질 수 있는 특성을 가지고 있다. 그러나 이러한 유기발광 소자의 경우 높은 발광 효율을 위한 구조적 개선이 필요하며 소자의 수명도 개선해야 한다. 이에 따라 유기발광 소자의 메카니즘에 대한 파악이 필요하게 되며 물리적 구조에 대한 이해가 필요하다. 이를 위해 물리적, 수치적 해석으로 소자의 특성을 파악해 줌으로써 개선된 유기발광 소자 제작이 가능 할 것이다.기에 대한 영향정도를 측정하여 정량적으로 도출하였다. 이를 각 구간에 대해 상호 비교 분석함으로써 대형국책사업에서의 공기지연인자에 대한 분석 방법론을 정립하였고 공기지연 분석 방법론의 현실적 적용을 위한 제언과 그에 따른 개선사항에 대해 도출하였다.있는 발판을 마련하게 된다고 추정하였다. 0.5%가 control사이에서 0.95로 가장 색차가 크게 나타났으며, 그 다음이 냉동분쇄 0.5% 0.83으로 나타나 송이의 첨가율이 높을수록 색차가 크게 나타나는 것을 알 수 있다. 색차가 가장 낮은 제품은 법동분쇄 0.3%, 동결건조 0.3%로 나타났다. 송이양갱의 색(color), 냄새(flavor), 맛(taste), 외관(appearances), 질감(viscosity), 종합적 평가(overall acceptability) 등의 관능평가를 실시한 결과 중 색에 대한 기호도는 냉동분쇄 0.1% 송이양갱이 가장 높은 것으로 나타났으나, 집단간 유의한 차이는 나타나지 않았고, 냄새는 동결건조 0.1%의 송이양갱이 3.38로 가장 점수가 높았으며, 냉동분쇄 0.3%의 송이양갱이 2.81로 가장 낮은 기호도를 나타내었다. 맛에서는 p<0.01수준에서 집단간 유의한 차이를 나타내었는데, 동결건조 0.1%가 그 중 가장 높은 기호도를 나타내었으며, 그 다음이 동결건조 0.5%였다. 가장 낮은 선호도를 나타낸 것은 열풍건조 0.5%였다. 질감은 P<.05 수준에서 집단간 유의미한 차이를 나타내었으며 동결건조 0.1%가 가장 높은 기호도를 나타내었으며, 동결건조 0.5%함유 송이양갱이 1.21로서, 현저히 낮은 기호도를 나타내었다. 종합적인 평가에서는 동결건조 0.1%함유

  • PDF

Applications of the Scanning Electron Microscope (주사형(走査型) 전자현미경(電子顯微鏡)의 응용분야(應用分野))

  • Kim, Yong-Nak
    • Applied Microscopy
    • /
    • v.2 no.1
    • /
    • pp.39-46
    • /
    • 1972
  • There are many kinds of microscopes suitable for general studies; optical microscopes(OM), conventional transmission electron microscopes (TEM), and scanning electron microscopes(SEM). The optical microscopes and the conventional transmission electron microscopes are very familiar. The images of these microscopes are directly formed on an image plane with one or more image forming lenses. On the other hand, the image of the scanning electron microscope is formed on a fluorescent screen of a cathode ray tube using a scanning system similar to television technique. In this paper, the features and some applications of the scanning electron microscope will be discussed briefly. The recently available scanning electron microscope, combining a resolution of about $200{\AA}$ with great depth of field, is favorable when compared to the replica technique. It avoids the problem of specimen damage and the introduction of artifacts. In addition, it permits the examination of many samples that can not be replicated, and provides a broader range of information. The scanning electron microscope has found application in diverse fields of study including biology, chemistry, materials science, semiconductor technology, and many others. In scanning electron microscopy, the secondary electron method. the backscattererd electron method, and the electromotive force method are most widely used, and the transmitted electron method will become more useful. Change-over of magnification can be easily done by controlling the scanning width of the electron probe. It is possible. to continuously vary the magnification over the range from 100 times to 1.00,000 times without readjustment of focusing. Conclusion: With the development of a scanning. electron microscope, it is now possible to observe almost all-information produced through interactions between substances and electrons in the form of image. When the probe is properly focused on the specimen, changing magnification of specimen orientation does not require any change in focus. This is quite different from the conventional transmission electron microscope. It is worthwhile to note that the typical probe currents of $10^{-10}$ to $10^{-12}\;{\AA}$ are for below the $10^{-5}$ to $10^{-7}\;{\AA}$ of a conventional. transmission microscope. This reduces specimen contamination and specimen damage due to heatings. Outstanding features of the scanning electron microscope include the 'stereoscopic observation of a bulky or fiber specimen in high resolution' and 'observation of potential distribution and electromotive force in semiconductor devices'.

  • PDF