• Title/Summary/Keyword: Catheters

Search Result 239, Processing Time 0.024 seconds

Systematic Review and Meta-Analysis of Antibiotic-Impregnated Shunt Catheters on Anti-Infective Effect of Hydrocephalus Shunt

  • Zhou, Wen-xiu;Hou, Wen-bo;Zhou, Chao;Yin, Yu-xia;Lu, Shou-tao;Liu, Guang;Fang, Yi;Li, Jian-wen;Wang, Yan;Liu, Ai-hua;Zhang, Hai-jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.297-308
    • /
    • 2021
  • Objective : Shunt infection is a common complication while treating hydrocephalus. The antibiotic-impregnated shunt catheter (AISC) was designed to reduce shunt infection rate. A meta-analysis was conducted to study the effectiveness of AISCs in reduction of shunt infection in terms of age, follow-up time and high-risk patient population. Methods : This study reviewed literature from three databases including PubMed, EMBASE, and Cochrane Library (from 2000 to March 2019). Clinical studies from controlled trials for shunt operation were included in this analysis. A subgroup analysis was performed based on the patient's age, follow-up time and high-risk population. The fixed effect in RevMan 5.3 software (Cochrane Collaboration) was used for this meta-analysis. Results : This study included 19 controlled clinical trials including 10105 operations. The analysis demonstrated that AISC could reduce the infection rate in shunt surgery compared to standard shunt catheter (non-AISC) from 8.13% to 4.09% (odds ratio [OR], 0.48; 95% confidence interval [CI], 0.40-0.58; p=0.01; I2=46%). Subgroup analysis of different age groups showed that AISC had significant antimicrobial effects in all three groups (adult, infant, and adolescent). Follow-up time analysis showed that AISC was effective in preventing early shunt infections (within 6 months after implant). AISC is more effective in high-risk population (OR, 0.24;95% CI, 0.14-0.40; p=0.60; I2=0%) than in general patient population. Conclusion : The results of meta-analysis indicated that AISC is an effective method for reducing shunt infection. We recommend that AISC should be considered for use in infants and high-risk groups. For adult patients, the choice for AISC could be determined based on the treatment cost.

Resection and Prosthetic Replacement of Aneurysm of Aortic Arch (대동맥궁 동맥류 -치험 1례 보고-)

  • Ahn, Hyuk;Kim, Young-Jin;Rho, Joon-Rhang
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.274-279
    • /
    • 1980
  • A 21 years old male student was admitted because of mediastinal mass that was noticed in routine physical examination. He complained progressive hoarseness, mild dysphagia, and anterior chest pain on deep respiration. This mediastinal mass was diagnosed as aortic aneurysm involving ascending, transverse, and descending thoracic aorta with aid of aortogram. Total prosthetic replacement of aneurysm was performed successfully using extracorporeal circulation and hypothermia. For myocardial protection during aortic cross clamping, cardioplegic solution was used and topical myocardial cooling was also adapted For simplicity of cardiopulmonary bypass, Y-shaped connectors took cerebral perfusion catheters to the main perfusion line beyond the arterial pump. Total bypass time was 219 minutes, and aortic cross clamp time was 104 minutes. Recovery was uneventful except respiratory insufficiency for first 4 days. Isotope aortogram checked on post operative 30th day showed normal aortic configuration. He was discharged on post operative 35th day. A follow-up chest X-ray study 5 months later showed nearly normal anatomy.

  • PDF

Postoperative Delirium in Elderly Patients with Osteoarthritis Surgery: Incidence and Risk Factors (노인 환자의 골관절염 수술 후 발생한 섬망과 섬망 위험요인)

  • Park, Eun A;Kim, Min Young
    • Journal of muscle and joint health
    • /
    • v.22 no.2
    • /
    • pp.57-66
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the incidence of postoperative delirium in elderly patients with osteoarthritis surgery and identify risk factors for its development. Methods: This study enrolled 288 patients who underwent osteoarthritis surgery in a hospital between May and November 2014. Data were collected prospectively. The Nursing Delirium Screening Scale was used to detect delirium. Multivariable logistic regression analysis was used to identify independent risk factors for postoperative delirium. Patients were also followed for outcome. Results: Postoperative delirium developed in 42 patients (14.6%). Logistic regression analysis identified old age, low physical activity, antipsychotic agents, number of catheters, and intensive care unit admission as risk factors. Worse outcomes, including increased hospital mortality, reoperation, and discharge at care facilities, occurred in subjects who developed delirium. Conclusion: Osteoarthritis surgery in elderly patients was associated with a high incidence of postoperative delirium. The results of the this study regarding patient populations vulnerable to delirium should be taken into account so that such patients could be identified preoperatively or in the immediate postoperative period.

Prevalence and Related Risk Factors of Delirium in Intensive Care Units as Detected by the CAM-ICU (CAM-ICU로 평가한 중환자실의 섬망 발생률과 섬망 발생 위험요인)

  • Choi, Su Jung;Cho, Yong Ae
    • Journal of Korean Clinical Nursing Research
    • /
    • v.20 no.3
    • /
    • pp.406-416
    • /
    • 2014
  • Purpose: Screening of delirium using delirium assessment tools could promote delirium detection, however, there is lack of report about regular delirium assessment in Korea. This study was intended to describe the prevalence and related risk factors of delirium in intensive care unit (ICU). Methods: The Confusion Assessment Method for the ICU (CAM-ICU) data which were evaluated by nurses in ICUs was obtained through retrospective chart review. Data were analyzed using descriptive statistics, Chi-square test, t-test, Mann-Whitney U test, and stepwise logistic regression. Results: Delirium was evaluated in 125 patients. The incidence rate of delirium was 27.2% with a high prevalence of hypoactive delirium compared to hyperactive delirium (61.8 vs. 38.2%). Those with delirium were older, had hypertension, stayed longer in hospital, receiving ventilator support, had more number of catheters, had low serum protein and albumin level. Delirium incidence also varied according to diagnosis. Age, diagnosis of gastrointestinal disease, and application of ventilator were the significant risk factors for the incidence of delirium. Conclusion: Routine delirium screening is important for early detection of delirium. Identification of high-risk group and running delirium prevention programs could improve early recognition of delirium in ICU.

Factors Associated with Central Venous Catheterization in Cancer Patients (암환자의 중심정맥관 삽입 예측요인)

  • Park, Jeong-Yun;Park, Yeon-Hwan
    • Asian Oncology Nursing
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Purpose: The purpose of this study was to identify the types of venous access devices (VAD) for cancer patients and investigate the factors related to the insertions of central venous catheter (CVC) in cancer patients. Methods: The subjects were 379 cancer patients. A retrospective review of all patients who were discharged from a cancer unit from November 1st to 21st in 2008 was done using a structured questionnaire. Results: A total of 82 CVC (21.6%) was inserted among 379 patients for administering anticancer therapy. There were statistically significant differences in age, length of stay (LOS), cumulative LOS, medical department, history of CVC insertion, cancer category, and albumin level between patients using peripheral intravenous (IV) catheters and CVC. In addition, factors influencing the use of CVC were LOS (odds ratio [OR]=0.286, confidence interval [CI]=1.043-1.124), history of CVC insertion (OR=3.920, CI=0.128-0.637), albumin level (OR=1.010, CI=1.879-8.179), cumulative LOS (OR=1.010, CI=1.001-1.018), and hematological diseases (OR=4.863, CI=2.162-10.925). Conclusion: We found that central venous catheterization for anticancer therapy was minimal even though CVC was safe and effective device for IV access. It is necessary to develop a strategy to use VADs efficiently and timely for cancer patients.

The Development of the Shunt Guiding Kit for the Proper Positioning of the Proximal Shunt Catheter to the Lateral Ventricle in the Ventriculo-Peritoneal Shunt Operation (뇌실-복강간 단락술에서 Proximal Catheter의 정확한 측뇌실내로의 위치를 위한 Shunt Guiding Kit의 개발)

  • Shin, Yong Sam;kim, Se-Hyuk;Zhang, Ho Yeol;Bae, Ju Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.981-984
    • /
    • 2001
  • Object : To treat hydrocephalus by ventriculo-peritoneal shunt operation, the correct positioning of the proximal catheter in the ventricle is very important. The purpose of this study was to develop the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle in the ventriculo-peritoneal shunt operation. Materials and Methods: The "shunt guiding kit" is made of tungsten alloy and it consists of one frame, two screws and one guider. Through the guider, the proximal shunt catheter operates by mechanically coupling the posterior burr hole to the anterior target point. Results: We have treated three hydrocephalus patients with use of the "shunt guiding kit", and achieved good location of proximal shunt catheters. Conclusion: We developed the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle, and this would be very useful for preventing ventriculo-peritoneal shunt malfunction and preventing possible brain injury during the procedures.

  • PDF

Effectiveness of Bacterial Filter in Continuous Epidural Block (지속적 경막외차단시 세균여과기의 효과에 관한 연구)

  • Yoon, Jun-Rho;Han, Seok-Ho;Chung, Eun-Yong;Kim, Ae-Ra;Han, In-Su;Lee, Chul-Woo
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.230-234
    • /
    • 1998
  • Background: Continuous epidural block is widely used for surgical operation and postoperative pain management. The potential infection due to the epidural catheter is a definite harzard of continous epidural block. We investigated the effectiveness of bacterial filter in prevention of infection due to the epidural catheter. Methods: Patients scheduled for transabdominal hysterectomy were assigned to two groups by simple randomization (50 patients per group). All catheters were placed in the 2nd and 3rd lumbar epidural space, using careful sterile technique. Group 1 received injections by the epidural catheter with a bacterial filter and group 2 received injections by the epidural catheter without a bacterial filter. The infection rate in the tips of epidural catheter left for 3 days were compared between the two groups. Results: There was no significant difference in the infection rate between two groups. Conclusions: A bacterial filter of the epidural catheter for surgical anesthesia and postoperative analgesia dose not prevent all kinds of infection in continuous epidural block.

  • PDF

Interpleural Catheter in the Management of Chronic Refractoy Upper Abdominal Pain -A case report- (늑막강내 카테터를 이용한 난치성 상복부통증의 치료경험 2예)

  • Lee, Kee-Heung;Lee, Geun-Bo;Park, Sung-Sik;Hong, Jung-Gil
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.317-320
    • /
    • 1998
  • Since Reiestad and Str$\ddot{o}$mskag reported interpleural installation of local anesthetic solutions as a technique for the management of postoperative pain in the patients undergoing cholecystectomy, renal surgery and breast surgery, many physician applied this technique for upper abdominal pain from various reasons such as technically simple, effective pain relief, less respiratory depression. So we tried interpleural analgesia in two patients who suffered from severe upper abdominal pain. One had upper abdominal pain due to chronic pancreatitis and the other had right upper abdominal pain after PTBD (percutaneous transhepatic bile drainage) for biliary cirrhosis and systemic jaundice. Both were injected 10 ml of 1% lidocaine and infused continuously with 1% lidocaine (2 ml/hr) using 2-Day Baxter$^{(R)}$ infusor. After bolus injection of lidocaine, pain scores (VAS 0~100) were recorded below 25mm and had not exceed that level during continuous infusion. After removing the catheters, two patients were all satisfied with this therapy. Our experiences with this technique showed that continuous infusion of local anesthetics through an interpleural catheter is effective in the control of refractory upper abdominal pain without any complication.

  • PDF

Effect of Electromagnetic Navigated Ventriculoperitoneal Shunt Placement on Failure Rates

  • Jung, Nayoung;Kim, Dongwon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.150-154
    • /
    • 2013
  • Objective : To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. Methods : All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. Results : A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). Conclusion : The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.