• Title/Summary/Keyword: Catheter insertion

Search Result 154, Processing Time 0.025 seconds

Usefulness of Tunneled Trans-saphenous IVC Catheters for Long Term Venous Access in Pediatric Patients (소아환자에서 대복재정맥을 통한 하대정맥도관법의 유용성)

  • Kim, Seung-Hwan;Kim, Seong-Min;Oh, Jung-Tak;Han, Seok-Joo;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.167-174
    • /
    • 2006
  • Central venous catheter (CVC) for long-term venous access is indispensable for various reasons including hyperalimentation, frequent blood sampling, frequent IV drug use in pediatric patients. We report clinical experience of surgical neonates in whom CVC was inserted primarily via great saphenous vein into suprarenal inferior vena cava. From March 2004 to March 2006, we performed CVC insertion via saphenous vein - contralateral side to main wound - into suprarenal inferior vena cava in surgeries of neonates. 2.7Fr or 4.2Fr, single lumen, tunneled Broviac catheters (Bard Access system, Inc, Salt Lake City, Utah) were used. Skin exit site of tunneled catheter was located in ipsilateral flank area just below edge lower rib. At the end of the procedure, location of the catheter tip was confirmed by plain radiography of abdomen. We retrospectively reviewed the admission records of the patients including nursing staff charts. Nine (50.0 %) patients were male and nine (50.0%) were female. Median gestational age was 38 weeks (range, 29-42 weeks) and median birth weight was 3,105 gm (range, 1,040-3,720 gm). Median age at catheter insertion was 38.5 days (range, 1-236 days). The purpose of CVC insertion was short-and long-term hyperalimentation in nine (50.0 %) patients. CVC insertion was performed in operation room under general anesthesia in sixteen (88.9 %) patients (in these cases, CVC insertion was performed just prior to concurrent operation) and neonatal intensive care unit (NICU) under local anesthesia with adequate sedation in two (11.2%). During the admission period (total catheter-indwelling time: 553 days), CVC functioned well without any significant side effects. Transient swelling of the ipsilateral leg (n=1, 5.6 %) and transient migration of catheter tip (n=1, 5.6 %) were noted, which did not affect function of the indwelled CVC. Mean catheter-indwelling time was 30.7days (range, 3-72 days). All catheters were removed electively except two mortality case. Complications, such as thrombosis, infection, kinking or extravasation of drugs, were not observed in our study period. Tunneled trans-great saphenous vein inferior vena cava catheters are not only comparable to cervical CVCs in terms of function and complication rates, but also very beneficial in selected patients, especially those in whom cervical approach is technically impossible or contraindicated.

  • PDF

Successful Surgical Treatment of Acute Mediastinitis after Central Catheter Insertion - One case report - (중심정맥관 삽관 후 발생한 급성 종격동염의 수술치료 - 1예 보고 -)

  • Lee, Jae-Ik;Choi, Pill-Jo;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.388-391
    • /
    • 2007
  • Subclavian catheter insertion is now widely used because of its technical feasibility and effectiveness, but some complications related to this procedure have been noted. We present here a rare surgical case of post central line insertion mediastinitis with no mechanical complication.

Predictive Factors for Symptomatic Dislodgement of Percutaneous Transhepatic Biliary Drainage Catheter in Patients with Malignant Biliary Obstruction (악성 담관 폐쇄 환자에서 경피경간 담도 배액술의 유증상 이탈 발생의 예측 인자)

  • Hee Jeong Yu;Jung Gu Park;Gyoo Sik Jung;Kwang Il Seo;Hyun Joon Park;Jong Hyouk Yun
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1350-1360
    • /
    • 2023
  • Purpose To evaluate the factors that predict symptomatic dislodgement of a percutaneous transhepatic biliary drainage (PTBD) catheter in patients with malignant biliary obstruction. Materials and Methods This retrospective study included 572 patients with malignant biliary obstruction who underwent 733 PTBD catheter insertions between January 2010 and February 2015. The duration of catheter placement, approach site, location of the catheter tip, insertion angle, presence of a closed-loop pigtail, and tube diameter were evaluated. Results During the follow-up period, 224 PTBD catheter dislodgements (30.56%) were observed in 157 patients. Among them, 146 (19.92%) were symptomatic. The mean duration from catheter insertion until dislodgement was 32 days (range: 1-233 days). Male (odds ratio [OR]: 1.636, 95% confidence interval [CI]: 1.131-2.367, p = 0.009), right-sided approach (OR: 1.567, 95% CI: 1.080-2.274, p = 0.018), increased insertion angle (OR: 1.015, 95% CI: 1.005-1.026, p = 0.005), and incomplete closed-loop pigtail formation (OR: 1.672, 95% CI: 1.098-2.545, p = 0.016) were independent factors predictive of symptomatic dislodgement of a PTBD catheter. Conclusion Factors predictive of symptomatic catheter dislodgement included male sex, a right-sided approach, increased insertion angle, and incomplete closed-loop pigtail formation.

A Peripherally Inserted Central Catheter is a Safe and Reliable Alternative to Short-Term Central Venous Catheter for the Treatment of Trauma Patients

  • Ryu, Dong Yeon;Lee, Sang Bong;Kim, Gil Whan;Kim, Jae Hun
    • Journal of Trauma and Injury
    • /
    • v.32 no.3
    • /
    • pp.150-156
    • /
    • 2019
  • Purpose: To determine whether a peripherally inserted central catheter (PICC) meets the goals of a low infection rate and long-term use in trauma patients. Methods: From January 2016 to June 2018, the medical records of patients who underwent central venous catheterization at a level I trauma center were retrospectively reviewed. Data collected included age, sex, injury severity score, site of catheterization, place of catheterization (intensive care unit [ICU], emergency department, or general ward), type of catheter, length of hospital stay during catheterization, types of cultured bacteria, time to development of central line-associated bloodstream infection (CLABSI), and complications. Results: During the study period, 333 central vein catheters (CVC) were inserted with a total of 2,626 catheter-days and 97 PICCs were placed with a total of 2,227 catheter-days. The CLABSI rate was significantly lower in the PICC group when the analysis was limited to patients for whom the catheter was changed for the first time in the ICU after CVC insertion in the ER with similar indication and catheter insertion times (18.6 vs. 10.3/1,000 catheter-days, respectively, p<0.05). The median duration of catheter use was significantly longer in the PICC group than in the CVC group (16 vs. 6 days, respectively, p<0.05). Conclusions: The study results showed that the duration of catheter use was longer and the infection rate were lower in the PICC group than in the CVC group, suggesting that PICC is a safe and reliable alternative to conventional CVC.

A double-knotted pulmonary artery catheter with large loop in the right internal jugular vein -A case report-

  • Yoon, Kyoung Sub;Kim, Jung A;Hong, Jeong In;Kim, Jeong Ho;Park, Sang Yoong;Choi, So Ron
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.240-244
    • /
    • 2018
  • Knotting of a pulmonary artery catheter (PAC) is a rare, but well-known complication of pulmonary artery (PA) catheterization. We report a case of a double-knotted PAC with a large loop in a patient with hepatocellular carcinoma (HCC) undergoing liver transplantation, which has been rarely reported in the literature. A PAC was advanced under pressure wave form guidance. PAC insertion was repeatedly attempted and the PAC was inserted 80 cm deep even though PAC should be normally inserted 45 to 55 cm deep. However, since no wave change was observed, we began deflating and pulling the balloon. At the 30-cm mark, the PAC could no longer be pulled. Fluoroscopy confirmed knotting of the PAC after surgery (The loop-formed PAC was shown in right internal jugular vein); thus, it was removed. For safe PA catheterization, deep insertion or repeated attempts should be avoided when the catheter cannot be easily inserted into the pulmonary artery. If possible, the insertion of PACs can be performed more safely by monitoring the movement of the catheter under fluoroscopy or transesophageal echocardiography.

Relationship between Nursing Task Overload and Aseptic Technique Performance in Clinical Nursing Skills (임상 간호사의 역할과부담과 기본간호술 수행 시의 무균술 이행의 관계)

  • Lee, Sun-Ok;Park, Kyung-Yeon
    • Journal of East-West Nursing Research
    • /
    • v.15 no.1
    • /
    • pp.18-25
    • /
    • 2009
  • Purpose: The study was investigated to identify the relationship between nursing workload and aseptic technique performance by clinical nurses, and to decrease the incidence rate of nosocomial infection. Methods: Participants (N=283) were recruited in B city from April to June 2007. The data were collected by a structured questionnaire and analyzed with descriptive statistics, t-test, ANOVA and Pearson's correlation coefficient. Results: Nursing workload was rated 9.85 out of a total score of 15. The level of aseptic technique performance as the basis for insertion of a Foley catheter was 42.72 out of a total score of 50, and as basis for insertion of intravenous catheter for fluid therapy was 40.11 out of a total score of 55. There was not a significant relationship between aseptic technique performance and nursing workload. There was a significant positive relationship between the aseptic technique performance in insertion of Foley catheter and that of intravenous catheter for fluid therapy (r=.279, p<.001). Conclusions: Attention to asepsis by nurses is crucial in nosocomial infection-related clinical nursing skills.

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF

Inadvertent Arterial Catheterization of Central Venous Catheter: A Case Report (중심정맥관의 동맥 내 거치: 증례보고)

  • Oh, Seung-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.292-294
    • /
    • 2015
  • Central venous catheterization is one of the most important procedures for initial resuscitation of hemodynamically unstable patients including multiple trauma patients. Inadvertent arterial placement of the large caliber central venous catheter can results in resuscitation failure as well as unnecessary invasive treatment. Here, we report an arterial puncture during central venous catheterization which may lead to inadvertent arterial catheterization. We recommend that arterial catheterization should be evaluated before dilator insertion during Seldinger's method. Ultrasound can help in preventing the inadvertent arterial catheterization of central venous catheter.

  • PDF

Complete atrioventricular block during tunneled cuffed hemodialysis catheter insertion in a patient with pre-existing left bundle branch block

  • Choi, Eun Woo;Jung, Ji Yoon;Su, Jun Huck;Park, Sae Huyn;Cho, Kyu Hyang;Yoon, Kyung Woo;Park, Jong Won;Do, Jun Young;Kang, Seok Hui
    • Journal of Yeungnam Medical Science
    • /
    • v.32 no.2
    • /
    • pp.152-154
    • /
    • 2015
  • Arrhythmias are complications of tunneled cuffed hemodialysis catheter insertion. Most complications associated with arrhythmias occur during guide-wire access, where the guide wire can cause traumatic damage to the conduction system of the heart. Conducting system injury in tunneled cuffed hemodialysis catheter insertion often involves the right bundle, causing right bundle branch block (RBBB). Transient RBBB with sinus rhythm is not usually accompanied by abnormal vital signs. However if patients already have left bundle branch block (LBBB), new onset RBBB can cause complete atrioventricular block (AVB), which can lead to fatal complications requiring invasive treatment. We report on a patient with LBBB who developed complete AVB during hemodialysis catheter insertion.

Continuous Axillary Branchial Plexus Block -I. Modification of catheter insertion method- (지속적 액와부 상완신경총 차단술 -I. 카테테르 삽입방법의 변형-)

  • Lee, Hoo-Jeon;Tae, Il-San
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.225-230
    • /
    • 1997
  • Background: Authors modified the traditional continuous axillary brachial plexus block technique of Selander for purpose of increasing success rate and decreasing complications by use of commercial epidural anesthesia set. Method: Thirty-nine patients scheduled for upper extremity operations were injected with 40 ml of anesthetic solution by axillary perivascular technique, using 23~25G immobile needle at 2 cm from the pectoralis major. Tuohy needle was immediately introduced at 4 cm from the pectoralis major and pierced the expanded neurovascular sheath at an angle of 30 degree to the skin. The "pop" was well noted well. Needle was advanced 0.5 to 3.0 cm and epidural catheter introduced through the needle. After removal of needle, occlusive dressing was done. Tip of catheter and spread of solution were demonstrated by fluoroscopy with contrast dye after completion of procedure. Result: Catheter insertion was successful at first attempt for all case. Total length of insertion was from 6 to 13($10.0{\pm}1.7$) cm. Tip of catheter was placed in infraclavicular space(66.7%), about the humeral head(17.9%) and in upper arm in 3 cases as U-shape(7.9%). Catheters were maintained for $6.7{\pm}2.6$(3-12) days. There were no complications such as: perforation of major vessels, needle trauma to nerve, infection, bleeding or hematoma. Conclusion: This study demonstrated continuous axillary brachial plexus block with epidural anesthesia set is safe, easy and convenient modification of technique of Selander.

  • PDF