• 제목/요약/키워드: Catenary system

검색결과 411건 처리시간 0.027초

4월점 등매개요소를 이용한 인장막구조(引張膜構造)의 형상해석(形狀解析) 및 응력해석(應力解析) (Shape Finding and Stress Analyses of Tension Membrane Structures by using 4-node Isoparametric Elements)

  • 이경수;이형훈;문정호;한상을
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.222-229
    • /
    • 2004
  • This study purports to analyze equally stressed surfaces in tension-membrane structures through a geometrically nonlinear approach. It adopts the formulation of a 4-node quadrilateral isoparametric plane stress element considering the orthotropic characteristic of membrane textures. Tension structures, which include cables and tension membranes, such as a cable dome initially exhibit unstable conditions because no initial internal stiffness such as bending stiffness is present. Such a structural system requires prestressing to the tension members to attain a stable state. A tension-membrane structure retains a stable three dimensional curved surface as a structural shape. This analytical process for finding the geometry is referred to as Shape Finding Analysis. In order to assess the validity of this study, we examine equally stressed surfaces of saddle and catenary shape shell structures and carry out pertinent stress analyses

  • PDF

AT 교류 철도급전계통 내 다수 열차 운행시 새로운 계통해석 알고리즘 연구 (Applying New Algorithm on AC Auto-Transformer Feeding System under Multiple Trains Operating)

  • 전용주;추동욱;전명수;임성정;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.712-719
    • /
    • 2000
  • This paper presents a new algorithm to analyze a train voltages of multi-trains in auto-transformer-fed AC railway systems, using electrical equivalent change. The train current will be divided into circulation and return currents, and these current values are the same. By evaluating each current independently, the result will be more precise. The train current flows through the all auto-transformer corresponding to track impedance. In analyzing the railway system, the algorithm is based on the K.C.L, K.V.L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that tile proposed method is easily applied.

  • PDF

DC 급전계통 고저항 지락보호에 대한 연구 (A Study on High Impedance Grounding Protection for DC Power Supply System)

  • 이국명;김병현;소선영;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.878-884
    • /
    • 2006
  • Grounding fault and short of the DC power supply systems are detected and protected by high-speed circuit breaker, linked breaking device, ground relay and fault selective device, all of which are installed and operated in substaions. however, there have been many cases in which the protective devices did not detect grounding of of the over head catenary systems on concrete support for an extended period of time. Such cases often cause severe damages to the supports with high grounding resistances. If grounding accidents occur repetitively, the earth current and the rise of earth potential can damage not only passenger and staff but also electric facilities and equipment, necessitating high cost and endeavor to restore. The following study points out various problems that can be occurred occur as a result of high impedance grounding accident, and proposes a new system which can protect and intercept them.

  • PDF

전차선로 시스템의 축약 등가 선로정수에 관한 연구 (A Reduced Equivalent Line Constant of the Catenary System)

  • 이한민;오광해;이장무;박현준;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.421-431
    • /
    • 2004
  • Line constants are composed by impedances and susceptances. A paper which was published estimated only impedances of line constants. Therefore, this paper estimates susceptances as well as impedances of equivalent five-conductors model using the reduced equivalent method. In order to verify estimated line constants, we measured line constants of real railway system. And we compared calculated results with measured data on 60Hz∼3000Hz. For the other verification, the calculation results from the proposed model and the measurement data from the test are compared focused on the amplification of harmonic current in the paper.

영상처리를 이용한 가동브래킷 변형 검사 기법에 대한 연구 (A Study on Cantilever Deformation Inspection Method Using Image Processing)

  • 한승훈;조민수;유영기;이병곤
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.988-994
    • /
    • 2017
  • The risk of facilities in catenary is increasing because the railway section extension and high-speed train service. And visual check of workforce is not enough time to maintain the extensive railway facilities. Accordingly, The technical development trend of maintenance of railway facilities can be seen by automation and application of IT technology, especially the mechanization work and the information technology are spreading in the maintenance work of the train line solved by manpower. In this paper, we describe the method by obtaining the cantilever image using acquisition device and pole inspection system in high speed vehicle, to check the variation of the cantilever component using image processing.

회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가 (Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis)

  • 오광해;차준민
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

고속 전차선로 드로퍼에 대한 기계적 하중에 관한 연구 (Mechanical Loads of Dropper for High Speed Electric Railway)

  • 이기천;이태훈;이종우
    • 한국철도학회논문집
    • /
    • 제14권3호
    • /
    • pp.222-227
    • /
    • 2011
  • 드로퍼는 전차선로에서 여러형태의 클램프로 취부되어 전차선이 수평으로 유지하도록 지지하고, 판토그라프가 통과할 때 굽힘에 대한 기계적 응력에 영향을 받는다. 고속선용 드로퍼의 파단 원인을 조사하기 위해, 이론적 분석 및 시험을 실행하였다. 본 논문에서 사전이도에 의한 드로퍼의 정적 하중을 계산하였고, 시험에서 측정된 값과 유사하였다. 드로퍼 와이어의 파단원인을 분석하기 위해 현장에서 파단된 시료는 SEM 분석을 하였고, 새 시료도 일부 병행하며 시행하였다. 마지막으로, 고속열차가 300km/h로 통과할 때 드로퍼에 대한 동적 하중의 변화를 측정하였다. 기계적 하중이 반복적으로 발생될 때, 드로퍼 와이어는 피로에 의해 파단될 것이다. 이 결과는 고속전차선로 유지보수의 특별 관리와 드로퍼의 수명평가를 하는데 활용될 수 있을 것이다.

전기철도의 공용접지 시스템에 대한 안정성 평가에 관한 연구 (Safely Evaluation on Common Grounding System for Electric Railway)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.298-306
    • /
    • 2002
  • We performed an safety evaluation on constructing of a common grounding system for electrical railway in view of its efficacy and technical fit. In order to compare the conventional grounding method, which has been individually conducted, with the common grounding with all ground wires connected in common to the counterpoise buried below the surface of the earth in parallel with rail, we set up scenarios with several cases of fault and load conditions in Chungbuk railway sections with the common grounding system. Based on models for railway conductors including the grounded system, line Parameters of railway power system are computed. The circuit model for power system with up and down lines, auto-transformers and railway substations is used to compute impedances of counterpoise and substation ground net. For each scenario with faults and operation conditions of railway, the induced potentials on signal and communication lines are also computed. It is shown that the common grounding for Chungbuk railway is superior experimentally to the conventional method in three respects: (1) the lower rail potentials during operation of railway in line, (2) the lower rail potentials for short-circuit faults between catenary and rail, and (3) the lower stress voltages on signal and communication lines for short-circuit or ground faults. The analysis results confirm that the grounding system for electric railway is required to be built by the common grounding and be evaluated on its safety in design.

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

차세대고속철도기술개발사업 시스템인터페이스 시험기술 개발 (Development of the technology to verify the systems interface for the High speed Electric Multiple Unit)

  • 강병모;정상국;안효권;최환침;유승위
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.810-815
    • /
    • 2010
  • Since a long time ago, many railway engineers analyze and discuss the interface between the sub-system of railway, such as a wheel/rail interface, pantograph/catenary interface etc. The verifying of the system interface could help to achive the optimized performance and safety of the railway system considering that the railway system is constructed by various engineerings, such as civil, mechanical, electrical, etc. A rolling stock with distributed drive system, which will be developed by HEMU-400x project, is capable of running on high speed line and conventional line in Korea. To verify the performance of rolling stock, test run will be done with revenue service line. And the test items of the system interface have to be selected to verify a functional compatibility and physical force between rolling stock and infrastructure. In this paper, the authors will indicates the test items to verify system interface. To achive the conclusion, the authors analyze a specification of the development train and the design value of Seoul-Busan high speed line, which will be used for testing of the development train, and also, study the various case of high speed train commissioning.

  • PDF