• Title/Summary/Keyword: Catenary system

Search Result 410, Processing Time 0.026 seconds

Development of Detail Design Software for High Speed Catenary System (고속전차선로 상세설계 자동차 소프트웨어 개발)

  • Kim, Joo-Rak;Lee, Ki-Won;Chang, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.257-259
    • /
    • 2002
  • This study presents a development of DeCatS which is software to design high speed catenary system automatically. This is developed by KRRI with the support of KHSR. This paper presents a process of developing this S/W and a comparison with LEXCAT is demonstrated a preciseness of this.

  • PDF

A Development of Automatic materials management D/B for High-speed catenary system (고속전차선로 설계자동화를 위한 자재관리 D/B의 설계 및 개발)

  • Lee, Ki-Won;Kim, Joo-Rak;Chang, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.263-265
    • /
    • 2002
  • This paper presents a design method of database to manage materials having hierarchical structure on Kyungbu high-speed catenary system. Through this method, the automatic management software was developed. The software can get to find out assemblies as well as single fittings used in a section.

  • PDF

Active Control of a High-Speed Pantograph using LQ-Servo Controller

  • Shin, Seung-Kwon;Song, Young-Soo;Eum, Ki-Young;Koo, Dong-Hoe
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1173-1177
    • /
    • 2004
  • The high investment is necessary for the new high speed lines. So the KRRI was interested in the possibility of upgrading the existing line in order to speed up the train in the conventional lines. The tilting train system has been developed because the reconstruction of railway for the cant compensation costs very high. The purpose of the tilting system is to compensate the centrifugal acceleration in order to reduce the lateral acceleration of the passenger at high speed on the curves.The pantograph of the tilting train is indispensable in order to supply the electrification equipments with power in safe. The dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force and the contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the active control of pantograph and presents the LQ-servo controller to reduce the contact force variation.

  • PDF

A Study on Durability Standard Specification of the Dropper Clamp of Catenary for High Speed Railway (고속철도 전차선로 드로퍼 클램프 내구성 기준 정립에 관한 연구)

  • Oh, Wan-Shik;Yang, In-Dong;Park, Byung-Gon;Hong, Seok-Jin;Kim, Seong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1431-1436
    • /
    • 2017
  • The high-speed railway of catenary system, supplies a stable electric power supply to the train by satisfying the special conditions between pantograph and trolley wire, which operates more than 250km/h mutually sliding and feeding electric lines. According to Korean Railway Standard KRS PW 0026-13 (R), the standard for the grip strength of the dropper clamp in conventional line is established, but the high-speed railway line is not yet. When the grip strength of the dropper clamp is detached from the catenary line of the high-speed railway line, various problems may occur, such as damage to the pantograph due to the collision and arcing. In this paper, it is expected to be used as a basic data for establishing the durability criteria of the high-speed railway dropper clamp by verifying the dropper clamp on the Gyeong-bu and Honam high-speed line.

Analysis of Contact Loss Arc Spectrum between Contact Wire and Pantograph Material using a Spectrometer (광계측기를 이용한 전차선-팬터그래프 재질별 이선아크 스펙트럼 분석)

  • Chang, Chin-Young;Jung, No-Geon;Park, Jong-Gook;Koo, Kyung-Wan;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1803-1808
    • /
    • 2013
  • To maintain contact between catenary and pantograph copper is important in order to transmit power smoothly on Current collection system. But, Arc discharge with strong light is generated because of contact loss. Therefore, Arc discharge detection is important measurement factor judging performance of current collection system. In this paper, It is described to results of arc discharge applying UV detection technology using arc generator. And Arc discharge was detected using the most commonly used processing catenary and rigid catenary and pantograph copper of electric rolling stock for securing arc detection instrument reliability. Results of contact loss detection instrument in this paper will be used for maintenance of current collection quality and system.

Design of Active Pantograph Controller (능동 판토그래프 제어기 설계에 관한 연구)

  • Ko Tae-Hwan;Um Ju-Hwan;Eum Ki-Young;Shin Seung-Kwon
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.361-366
    • /
    • 2005
  • The high investment is necessary for the new high speed lines. So the KRRI has been interested in the possibility of upgrading the existing line in order to speed up the train in the conventional lines. The pantograph in train is indispensable in order to supply the electrification equipments with power in safe. The pantograph and the overhead wire form a dynamic coupled system and they affect each other through the contact force. Unfortunately, as the operational speed of a train increases, the vibration of the pantograph and the overhead wire also increases. This may lead to a zero contact force between the pantograph head and the overhead wire, which can results in the loss of contact, arching and abrasion. If the arching and spark happen between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper describes the dynamic response between the pantograph and catenary system by the numerical simulations and presents the LQ-servo controller to reduce the contact force variation

A Study on the Measurement of Contact Force of Pantograph of Korean High Speed Train (한국형 고속전철 집전장치 접촉력 계측에 관한 연구)

  • Seo, Sung-Il;Cho, Yong-Hyun;Park, Choon-Soo;Mok, Jin-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1453-1457
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, a system to measure the contact force of pantograph is developed and installed on the prototype high speed train, Contact force prevents the pantograph from separating from the catenary. However, excessive contact force causes rapid erosion of catenary. The contact force can be divided into lift force and spring force. Contact force measurement is conducted while the train runs on the test track. The lift force is measured by the load cell on the roof separately and combined with the spring force of pan-head to form the contact force. Measured results show that the contact force of the pantograph of Korean High Speed Train is below the upper limit regulated by the high speed train standards. The contact force measuring system provides data to evaluate safety of the catenary system.

  • PDF

A Test Study on Interface Dynamics of Current Collection System in High Speed Trains

  • Kim, Jung-Soo;Han, Jae-Hyun
    • International Journal of Railway
    • /
    • v.4 no.2
    • /
    • pp.34-41
    • /
    • 2011
  • Using a test run data, the dynamics of the interface between the catenary and pantograph constituting the current collection system in high-speed trains are investigated. The test run signals are analyzed to determine the dynamic parameters critical to the current collection performance. There are found to be frequency components of the pantograph motion that are dependent on train speed as well as components that are stationary such as the resonant mode of the panhead suspension in the pantograph. From contact force measurement using load cell, the mean contact force was found to be stable while the fluctuating component was found to be dependent on the range of the frequency of the pantograph motion taken into account. The finding implies that numerical investigations reported in the literature that are based on lumped element models of the catenary and/or pantograph provide accurate predictions on the mean value but are of limited use in estimating fluctuation of the contact force. It is concluded that simulation studies based on lumped-element models which do not incorporate panhead structural vibration modes is inaccurate at high train speeds.

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF

The Electrical Properties and Resonant Frequency of Pt/Pb(Zr,Ti)$O_3$/Pt Films (Pt/Pb(Zr,Ti)$O_3$/Pt 박막의 전기적 특성과 공진주파수에 관한 연구)

  • Park, Young;Lee, Ki-Won;Jang, Dong-Uk;Park, Hyun-June;Park, Gi-Yub;Choi, Won-Seok;Song, Joon-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1552-1554
    • /
    • 2004
  • The modeled resonant frequency and electrical properties of Pb(Zr, Ti)$O_3$ (PZT) film with various thicknesses have been investigated in film bulk acoustic wave resonators (FBARs). PZT films and Pt electrodes were fabricated by rf-magnetron sputtering. Fabrication process of electrodes and PZT were patterned by simple lift-off process and then back side of silicon was etched by 45wt% KOH. The crystal structure of PZT films with 0.5, 1 and 2 ${\mu}m$ thickness was investigated by x-ray deflection (XRD) and scanning electron microscopy (SEM). The dielectric constant and performance characteristics of PZT FBAR strongly depended on the film thickness. The resonant frequency of PZT films decreased with increasing film thickness. These sputtered PZT FBAR with simple lift-off process enable us to fabricate high Q values with resonant frequencies. (0.71 - 1.48 GHz).

  • PDF