• Title/Summary/Keyword: Catchment area

Search Result 323, Processing Time 0.04 seconds

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

A Study on the Hydrologic Design of Detention Storage Ponds in Urbanized Area

  • Lee, Jung-Sik;Lee, Jae-Joon;Kim, Kyu-Ho
    • Korean Journal of Hydrosciences
    • /
    • v.7
    • /
    • pp.21-35
    • /
    • 1996
  • This Study is to develop the suitable hydrologic models for determination of the size and location of detention storage facilities to restrain stormwater runoff in urban areas. Hypothetical areas of two levels are considered to seize the hydrologic response characteristics. A one-square-kilometer ares is selected for the catchment level, and a 10-square-kilometer area consisting of 10 catchments is adapted at the watershed level as representative of urban drainage area. In this analysis, different rainfall freqyencies, land uses, drainage patte군, basin shates and detention storage policies are considered. Folw reduction effect of detention storage facilities is deduced from storage ratio and detention basin factor. A substantial saving in detention storage volumes is achieved 노두 the detention storage is planned at the watershed level rather than the catchment level. For the application of real watersheds, two watersheds in Seoul metropolitan area-Jamshil 2 and Seongnae 1-are selected on the basis of hydrologic response charactaristics. Through the regression analysis between dimensionless deterntion storage volume, dimensionless upstream area ratio and reduction rate of storage ratio, the regression equations to determine the size and location of detention storage faclities are presented.

  • PDF

Water resources potential assessment of ungauged catchments in Lake Tana Basin, Ethiopia

  • Damtew, Getachew Tegegne;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.217-217
    • /
    • 2015
  • The objective of this study was mainly to evaluate the water resources potential of Lake Tana Basin (LTB) by using Soil and Water Assessment Tool (SWAT). From SWAT simulation of LTB, about 5236 km2 area of LTB is gauged watershed and the remaining 9878 km2 area is ungauged watershed. For calibration of model parameters, four gauged stations were considered namely: Gilgel Abay, Gummera, Rib, and Megech. The SWAT-CUP built-in techniques, particle swarm optimization (PSO) and generalized likelihood uncertainty estimation (GLUE) method was used for calibration of model parameters and PSO method were selected for the study based on its performance results in four gauging stations. However the level of sensitivity of flow parameters differ from catchment to catchment, the curve number (CN2) has been found the most sensitive parameters in all gauged catchments. To facilitate the transfer of data from gauged catchments to ungauged catchments, clustering of hydrologic response units (HRUs) were done based on physical similarity measured between gauged and ungauged catchment attributes. From SWAT land use/ soil use/slope reclassification of LTB, a total of 142 HRUs were identified and these HRUs are clustered in to 39 similar hydrologic groups. In order to transfer the optimized model parameters from gauged to ungauged catchments based on these clustered hydrologic groups, this study evaluates three parameter transfer schemes: parameters transfer based on homogeneous regions (PT-I), parameter transfer based on global averaging (PT-II), and parameter transfer by considering Gilgel Abay catchment as a representative catchment (PT-III) since its model performance values are better than the other three gauged catchments. The performance of these parameter transfer approach was evaluated based on values of Nash-Sutcliffe efficiency (NSE) and coefficient of determination (R2). The computed NSE values was found to be 0.71, 0.58, and 0.31 for PT-I, PT-II and PT-III respectively and the computed R2 values was found to be 0.93, 0.82, and 0.95 for PT-I, PT-II, and PT-III respectively. Based on the performance evaluation criteria, PT-I were selected for modelling ungauged catchments by transferring optimized model parameters from gauged catchment. From the model result, yearly average stream flow for all homogeneous regions was found 29.54 m3/s, 112.92 m3/s, and 130.10 m3/s for time period (1989 - 2005) for region-I, region-II, and region-III respectively.

  • PDF

A study on the sediment yields and raising of the spillway crest for the reservoir capacity enlargement (저수지 유역의 토사 유입 및 여수토 숭상 효과 조사)

  • Nam, Myoung-Hee;Suh, Seung-Duk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.324-329
    • /
    • 2001
  • Sediment yields from the reservoir watershed areas and raising of the spillway crest for the agricultural reservoir capacity enlargement were investigated and analysed through the 21 pilot reservoirs, have irrigated areas 200has. and over in the Kyoungpook province. In these studies, (1), the correlation analysis between various watershed characteristics and annual specific sediment yields were derived and (2), the excess effective reservoir capacity of the over 0.5m above the spillway crest could be estimated. In brief, catchment area should strongly be correlated with the annual specific sediment yields (R=0.90), the other side, average slope of the main stream is less than catchment area. The excess effective capacity of reservoir enlargement by the raising of spillway crest at 0.5m-height was resulted 12.1% of increasing capacity compare with the original reservoir capacity.

  • PDF

How Much Development Can a Rail Station Lead? A Case Study of Hong Kong

  • Xue, Charlie Qiuli;Sun, Cong
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.95-109
    • /
    • 2018
  • Since the concept was first introduced in the 1970s, transit-oriented-development (TOD) has greatly expanded in East Asian cities such as Hong Kong. Rail stations are built together with clusters of residential-commercial towers and government services to form a new style of living - a "rail village." This paper examines the composition, scale, spatial form, organization and operation of several typical rail villages in Hong Kong. The cases range across those planned from the mid-1990s to 2015. Based on the analysis of the rail village composition, the paper derives a development ratio to indicate the density, effectiveness and efficiency of a rail village catchment area. The ratio provides a useful and direct figure for the comparison of different stations, cities and development modes.

Calculation of pollutant loadings discharged from domestic systems (분뇨 처리형태에 따른 축산계 오염부하량 산정(지역환경 \circled1))

  • 엄명철;공동수;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.500-506
    • /
    • 2000
  • Discharge characteristics of pollutant loadings from domestic systems were estimated in the catchment of a reclaimed area, Saemankeum. Pollutant loadings was estimated according to the discharge pattern of small treatment facilities. Recycled-fertilizer system was dominant in this area.

  • PDF

Rainfall Partitioning in a Small Catchment of a Monogenetic Volcano in Jeju Island: Case Study on Eoseungsaeng-oreum of Mount Halla (제주도 단성화산 소유역에서의 강우의 분배 - 한라산 어승생오름을 사례로 -)

  • An, Jung-Gi;Kim, Tae-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.3
    • /
    • pp.212-223
    • /
    • 2008
  • The rainfall partitioning in a monogenetic volcano has been analysed using the hydrological data of a small catchment on Eoseungsaeng-oreum of Mount Halla and the meterological data of Eorimok Automated Weather System. The experimental catchment extends from 965 m to 1,169 m in altitude, and has an catchment area of $51,000\;m^2$ Eoseungsaeng-oreum is the scoria cone predominantly covered with Carpinus laxiflora and Quercus serrata. The analyzed periods are April 30 to September 12 and October 7 to November 19, 2007. The experimental catchment exhibits the total precipitation of 2,296.5 mm. Surface runoff amounts to 465 mm that is equivalent to 20.2% of the precipitation. By contrast, evapotranspiration accounts for 25.9% of the precipitation, and the remnant of 1,236.5 mm deep1y percolates underground through a basement. The rainy summer season, in particular, shows the highest deep percolation ratio of 62.2%. The deep percolation ratio of the experimental catchment is at 1east more two times than the ratio of a gneiss basin in Korea Peninsular. It has suggested that the experimental catchment is characterized by the higher portion of deep percolation in rainfall partitioning which reflects the highly permeable lithology in Jeju Island.

  • PDF

Hydrograph Separation using Geochemical tracers by Three-Component Mixing Model for the Coniferous Forested Catchment in Gwangneung Gyeonggido, Republic of Korea

  • Kim, Kyongha;Yoo, Jae-Yun
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.5
    • /
    • pp.561-566
    • /
    • 2007
  • This study was conducted to clarify runoff production processes in forested catchment through hydrograph separation using three-component mixing model based on the End Member Mixing Analysis (EMMA) model. The study area is located in the coniferous-forested experimental catchment, Gwangneung Gyeonggido near Seoul, Korea (N 37 45', E 127 09'). This catchment is covered by Pinus Korainensis and Abies holophylla planted at stocking rate of 3,000 trees $ha^{-1}$ in 1976. Thinning and pruning were carried out two times in the spring of 1996 and 2004 respectively. We monitored 8 successive events during the periods from June 15 to September 15, 2005. Throughfall, soil water and groundwater were sampled by the bulk sampler. Stream water was sampled every 2-hour through ISCO automatic sampler for 48 hours. The geochemical tracers were determined in the result of principal components analysis. The concentrations of $SO_4{^{2-}$ and $Na^+$ for stream water almost were distributed within the bivariate plot of the end members; throughfall, soil water and groundwater. Average contributions of throughfall, soil water and groundwater on producing stream flow for 8 events were 17%, 25% and 58% respectively. The amount of antecedent precipitation (AAP) plays an important role in determining which end members prevail during the event. It was found that ground water contributed more to produce storm runoff in the event of a small AAP compared with the event of a large AAP. On the other hand, rain water showed opposite tendency to ground water. Rain water in storm runoff may be produced by saturation overland flow occurring in the areas where soil moisture content is near saturation. AAP controls the producing mechanism for storm runoff whether surface or subsurface flow prevails.

A Study on the Quantitative Model of the Reach of the Catchment and the Distance to Urban Community Parks (도시근린공원의 도달거리와 포착력에 관한 계량모형연구)

  • 권송준;심경구;김유일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.1
    • /
    • pp.149-177
    • /
    • 1994
  • This study is practically focussed on the derivation of the formula of the reach of the catchment of urban community parks and the reached distance to the parks. The hypotheses for the formula are as follows. a. The catchment of urban community parks can be dependent on the quantitative characteristics that urban community parks have substanial factors : the potential residential population of the proximate community to a park, park visitor's day and mean usetime per year. b. The distance to the urban park is a decided variable which can be percieved quantitatively by the researchers among the exogenous variables concerned with the mean usetime of the urban community park. The data for the variables were collected from the statistics, and the surveys for 9 parks of 4cities(Seoul, Chong-ju, Su-Won, Chon-an) in Korea, which were divided into on-site samples and off-site ones in 1991. The data were collected by questionaire surveys. A total of 548 questionaires of off-site surveys were completed by the residents in the enticing area of the parks. A total of 1053 questionaires of on-site surveys were completed by the visitors of the parks. The research could attempt to derive a formula, which was concerned with the reach of the catchment of urban community parks and the reached distance to the parks. It is testified(R2>0.8) that the numbers of mean usetime per year should be related with the reached distance from a visitor's house to a proximate park. The formula is analogized with an exponential function: {{{{ Mean Usetime per year=f(x)=Ae-BK+Ce-DK ear, X is reached distance from a visitor's house to a proximate park. A,B,C and D are parameters. And, the differences of the reach of the catchment of the parks are not only testified with resulting from the differences of the exogenous variables of qualitative characteristics differences of the parks, but also divided separately into spatial ranges. This formula will be able to anticipate the visitor's numbers of a planned urban community park.

  • PDF