• Title/Summary/Keyword: Cataract

Search Result 213, Processing Time 0.021 seconds

A Feature Point Tracking Method By Using Template Matching and Buffer (템플릿 매칭과 버퍼를 이용한 특징점 추적 방법)

  • Cho, Jeong-Hyun;Ahn, Cheol-Woong;Jun, Jae-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.173-179
    • /
    • 2014
  • Today, a surgery for cataract of Korean society frequently come to operation. A method for treating cataracts have been developed in various ways. Widely used method is a method to use the artificial lens and replace it with the existing lens. The surgery can be inserted exactly according to the angle and points that are calculated in advance in the intraocular lens insertion is important. However, The lens insertion point can delete or blur the display due to such factors as foreign material coming out of the eye during surgery. Therefore, The lens insertion point needs a method of tracking the image processing by receiving the camera images in real time display method. In this paper, we propose a feature point tracking method by using template matching and buffer. a simulation results show that our ideas can track a feature point of the intraocular lens insertion.

Risk Factors Associated with Cataract and Macular degeneration by in Korean aged 60 years and over (한국인 60세 이상 노년층의 황반변성과 백내장의 위험요인 -국민건강보험공단 노인코호트 자료를 활용하여-)

  • Pak, Hae-Yong;Lee, Eun-Hee;Pak, Yun-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.10
    • /
    • pp.273-279
    • /
    • 2017
  • Purpose: This study was conducted to identify factors associated with cataract and age-related macular degeneration in elders. Methods: In total, 341,588 men(44.18%,) and women(61.887%), aged over 60, were recruited from Korean National Health Insurance Service-Senior(2002-2013). We also analysed the factors which determine the prevalence of contract (ICD-10: H25) and age-related macular degeneration(ICD-10: H353) using Cox proportional hazard regression model Results: The subjects who were women, in older age, the group of higher income level, with hypertension, with heart disease, and with diabetes, the prevalence of both contract and age-related macular were increased(p<0.0001). Conclusion: The prevalence of contract and age-related macular degeneration were higher in old age of Korean who has chronic diseases such as hypertension, heart disease, and diabetes. The management of chronic diseases are essentially required in elderly for more healthy eye in aged society.

Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

  • Kim, Jae-Hyung;Moon, Tae Hwan;Chae, Ju Byung;Hyung, Sungmin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.546-550
    • /
    • 2014
  • To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PCI), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were $7.72{\pm}0.96$ and $4.45{\pm}1.04$, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.

Effects of Lycii fructus and Astragalus membranaceus Mixed Extracts on Immunomodulators and Prevention of Diabetic Cataract and Retinopathy in Streptozotocin-induced Diabetes Rat Model (Streptozotocin으로 유발한 당뇨병성 쥐에서의 당뇨병성 백내장과 망막병증에 대한 구기자와 황기 혼합 추출물 등의 면역 조절 및 예방 효과)

  • Jeon, Yun-Hui;Moon, Jun-Woong;Kweon, Hyuk-Jung;Jeoung, Young-Jun;An, Chi-Sun;Jin, Hai-Lan;Hur, Sun-Jin;Lim, Beong-Ou
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.1
    • /
    • pp.15-21
    • /
    • 2010
  • This study was conducted to investigate the effects of Lycii fructus and Astragalus membranaceus mixed extracts on immunomodulators and prevention in a streptozotocin-induced diabetes rat model. A total of 28 male rats were divided into four dietary groups and fed a commercial diet (A), commercial diet plus induced diabetes by a streptozotocin (STZ) injection (B), induced diabetes by STZ plus medicinal crop extracts(I&$H^{(R)}$) diet (C), and medicinal crop extracts (I&$H^{(R)}$) diet (D). Immunoblotting analyses revealed cytokine expression, and ELISA analyses revealed immunoglobulin E and nitric oxide production. As a results, the tumor necrosis factor-$\alpha$ (TNF-$\alpha$) and inducible nitric oxide synthase (iNOS) as a inflammatory cytokine were decreased. Interleukin-6 (IL-6) and signal transducer and activation of transcription 3 (STAT3) cytokine related in diabetes expression through JAK/STAT3 pathway were also decreased. Furthermore, immunoglobulin E and nitric oxide production were decreased in the serum and lens, respectively. These results suggest that Lycii fructus and Astragalus membranaceus mixed extracts provide positive effects on immunomodulators and prevention in diabetes and eye disease complications.

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera

  • Cho, Kyuyeon;Lim, Dong Hui;Yang, Chan-min;Chung, Eui-Sang;Chung, Tae-Young
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.497-505
    • /
    • 2018
  • Purpose: To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery. Methods: We performed a retrospective review of the medical records of 69 patients (69 eyes) who had undergone myopic laser refractive surgery previously and subsequently underwent cataract surgery at Samsung Medical Center in Seoul, South Korea from January 2010 to June 2016. None of the patients had pre-refractive surgery biometric data available. The Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug total corneal refractive power (TCRP) 3 and 4 mm (SRK-T and Haigis), Scheimpflug true net power, and Scheimpflug true refractive power (TRP) 3 mm, 4 mm, and 5 mm (SRK-T and Haigis) methods were employed. IOL power required for target refraction was back-calculated using stable post-cataract surgery manifest refraction, and implanted IOL power and formula accuracy were subsequently compared among calculation methods. Results: Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug TCRP 4 mm (Haigis), Scheimpflug true net power 4 mm (Haigis), and Scheimpflug TRP 4 mm (Haigis) formulae showed high predictability, with mean arithmetic prediction errors and standard deviations of $-0.25{\pm}0.59$, $-0.05{\pm}1.19$, $0.00{\pm}0.88$, $-0.26{\pm}1.17$, $0.00{\pm}1.09$, $-0.71{\pm}1.20$, and $0.03{\pm}1.25$ diopters, respectively. Conclusions: Visual outcomes within 1.0 diopter of target refraction were achieved in 85% of eyes using the calculation methods listed above. Haigis-L, Barrett True-K (no history), and Scheimpflug TCRP 4 mm (Haigis) and TRP 4 mm (Haigis) methods showed comparably low prediction errors, despite the absence of historical patient information.

Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery (버니 다초점인공수정체의 임상적 효용성)

  • Cho, Myung Ho;Park, Jae Yeong;Park, Byung Gun;Lee, Jong Soo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1129-1136
    • /
    • 2018
  • Purpose: To compare the postoperative clinical outcomes after cataract surgery and implantation using the BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ multifocal intraocular lenses. Methods: Sixty-five eyes implanted with multifocal intraocular lenses were divided into two groups involving either $ReSTOR^{(R)}$ (39 eyes) or BunnyLens $MF^{(R)}$ (26 eyes) lenses. In these two groups, the distant and near visual acuity, astigmatism, spherical equivalent, and contrast sensitivity test were examined at preoperative and postoperative 1 week, 8 weeks, and 24 weeks. We compared the clinical efficacy between the two groups before and after cataract surgery using statistical analysis. Results: The mean value of distant and near visual acuity, and spherical equivalent of both groups after intraocular lens implantation were significantly improved, compared with the preoperative values (p < 0.05), while there was no significant differences between the two groups (p > 0.05). The means of postoperative distant and near visual acuity, astigmatism, and contrast sensitivity test were not significantly different between $ReSTOR^{(R)}$ and BunnyLens $MF^{(R)}$ lenses (p > 0.05). The mean numeric error of spherical equivalent at the final postoperative 24 weeks was $-0.17{\pm}0.50$ diopters (D) for the $ReSTOR^{(R)}$ lenses and $-0.34{\pm}0.52D$ for the BunnyLens $MF^{(R)}$ lenses (p > 0.05). Conclusions: BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ lenses showed no significant difference in clinical efficacy, including distance and near vision, spherical equivalent error, and contrast sensitivity test after cataract surgery. However, it should be noted that BunnyLens $MF^{(R)}$ lenses had a tendency toward myopic shift compared with $ReSTOR^{(R)}$ lenses.

Heat shock transcription factors and sensory placode development

  • Nakai, Akira
    • BMB Reports
    • /
    • v.42 no.10
    • /
    • pp.631-635
    • /
    • 2009
  • The heat shock transcription factor (HSF) family consists of at least three members in mammals and regulates expression of heat shock proteins in response to heat shock and proteotoxic stresses. Especially, HSF1 is indispensable for this response. Members of this family are also involved in development of some tissues such as the brain and reproductive organs. However, we did not know the molecular mechanisms that regulate developmental processes. Involvement of HSFs in the sensory development was implicated by the finding that human hereditary cataract is associated with mutations of the HSF4 gene. Analysis of gene-disrupted mice showed that HSF4 and HSF1 are required for the lens and the olfactory epithelium, respectively. Furthermore, a common molecular mechanism that regulates developmental processes was revealed by analyzing roles of HSFs in the two developmentally-related organs.

Generalized Progressive Retinal Atrophy of Dogs in Korea: 34 Cases (국내 개에서의 전반적인 진행성 망막 위축증 34례)

  • 서강문;김완태;이나영;정만복;정성목;유형아;남치주
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.140-142
    • /
    • 2004
  • Thirty four dogs presented with generalized progressive retinal atrophy(gPRA) from September 2002 to April 2004 were reviewed to characterize signalments and prevalence rate in Korea. Mean age was 6.3$\pm$2.7 years-old and 59% was less than six years old. The most prevalent breed was Miniature Schnauzer (50%) and the affected mean age was slightly earlier (4.4$\pm$1.1 years-old). However, there was no sex predisposition. Cataract was confirmed in 15 dogs (44%) and 67% was bilateral.

Surface Enhanced Raman Spectroscopy-based Bio Sensing Technology Using Semiconductor Nanostructures (반도체 나노구조를 이용한 SERS기반 바이오센싱 기술)

  • Yu, Jae Su;Lee, Soo Hyun
    • Vacuum Magazine
    • /
    • v.4 no.3
    • /
    • pp.12-15
    • /
    • 2017
  • Surface enhanced Raman scattering (SERS) is considered as one of promising medical and diagnostic technologies. The SERS effect is caused by the localized surface plasmon resonance (LSPR) from metal nanoparticles with narrow hot spots. The mechanism of LSPR, development of nanostructure fabrication, and corresponding researches are discussed. The flexible, label-free, low-cost, and highly-sensitive Au/ZnONRs/G is introduced. The Au/ZnONRs/G detects and distinguishes cataract, age-related macular degeneration, and diabetic macular edema from aqueous humor. Comprehension of SERS provides further improvement in bio sensing technology including early diagnosis and prolonged life expectancy.realize highly stretchable electrodes.