Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

  • Kim, Jae-Hyung (Department of Ophthalmology, Chungbuk National University College of Medicine) ;
  • Moon, Tae Hwan (Department of Ophthalmology, Chungbuk National University College of Medicine) ;
  • Chae, Ju Byung (Department of Ophthalmology, Chungbuk National University College of Medicine) ;
  • Hyung, Sungmin (Department of Ophthalmology, Chungbuk National University College of Medicine)
  • Received : 2014.07.01
  • Accepted : 2014.09.16
  • Published : 2014.10.25

Abstract

To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PCI), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were $7.72{\pm}0.96$ and $4.45{\pm}1.04$, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.

Keywords

References

  1. T. Olsen, "Sources of error in intraocular lens power calculation," J. Cataract Refract Surg. 18, 125-9 (1992). https://doi.org/10.1016/S0886-3350(13)80917-0
  2. O. Findl, W. Drexler, R. Menapace, B. Kiss, C. K. Hitzenberger, and A. F. Fercher, "Optical biometry in cataract surgery," Dev. Ophthalmol. 34, 131-40 (2002). https://doi.org/10.1159/000060792
  3. O. Findl, W. Drexler, R. Menapace, C. K. Hitzenberger, and A. F. Fercher, "High precision biometry of pseudophakic eyes using partial coherence interferometry," J. Cataract Refract Surg. 24, 1087-93 (1998). https://doi.org/10.1016/S0886-3350(98)80102-8
  4. A. R. Wissa, S. S. Wahba, and M. M. Roshdy, "Agreement and relationship between ultrasonic and partial coherence interferometry measurements of axial length and anterior chamber depth," Clin Ophthalmol. 6, 193-8 (2012).
  5. W. Drexler, O. Findl, R. Menapace, G. Rainer, C. Vass, C. K. Hitzenberger, and A. F. Fercher, "Partial coherence interferometry: a novel approach to biometry in cataract surgery," Am. J. Ophthalmol. 126, 524-34 (1998). https://doi.org/10.1016/S0002-9394(98)00113-5
  6. J. Santodomingo-Rubido, E. A. Mallen, B. Gilmartin, and J. S. Wolffsohn, "A new non-contact optical device for ocular biometry," Br. J. Ophthalmol. 86, 458-62 (2002). https://doi.org/10.1136/bjo.86.4.458
  7. Y. T. Hsieh and I. J. Wang, "Intraocular lens power measured by partial coherence interferometry," Optom. Vis. Sci. 89, 1697-701 (2012). https://doi.org/10.1097/OPX.0b013e31827717ae
  8. Y. A. Chen, N. Hirnschall, and O. Findl, "Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer," J. Cataract Refract Surg. 37, 513-7 (2011). https://doi.org/10.1016/j.jcrs.2010.10.041
  9. P. J. Buckhurst, J. S. Wolffsohn, S. Shah, S. A. Naroo, L. N. Davies, and E. J. Berrow, "A new optical low coherence reflectometry device for ocular biometry in cataract patients," Br. J. Ophthalmol. 93, 949-53 (2009). https://doi.org/10.1136/bjo.2008.156554
  10. N. Hirnschall, S. Murphy, D. Pimenides, V. Maurino, and O. Findl, "Assessment of a new averaging algorithm to increase the sensitivity of axial eye length measurement with optical biometry in eyes with dense cataract," J. Cataract Refract Surg. 37, 45-9 (2010).
  11. T. Ueda, H. Ikeda, T. Ota, T. Matsuura, and Y. Hara, "Relationship between postoperative refractive outcomes and cataract density: Multiple regression analysis," J. Cataract Refract Surg. 36, 806-9 (2010). https://doi.org/10.1016/j.jcrs.2009.12.024
  12. T. Ueda, F. Taketani, T. Ota, and Y. Hara, "Impact of nuclear cataract density on postoperative refractive outcome: IOL master versus ultrasound," Ophthalmologica 221, 384-7 (2007). https://doi.org/10.1159/000107497
  13. L. T. Chylack, Jr., J. K. Wolfe, D. M. Singer, M. C. Leske, M. A. Bullimore, I. L. Bailey, J. Friend, D. McCarthy, and S. Y. Wu, "The lens opacities classification system III. The longitudinal study of cataract study group," Arch Ophthalmologica 111, 831-6 (1993). https://doi.org/10.1001/archopht.1993.01090060119035
  14. J. L. Davis, B. Madow, J. Cornett, R. Stratton, D. Hess, V. Porciatti, and W. J. Feuer, "Scale for photographic grading of vitreous haze in uveitis," Am. J. Ophthalmol. 150, 637-641 e1 (2010). https://doi.org/10.1016/j.ajo.2010.05.036
  15. T. S. Dietlein, G. Roessler, C. Luke, S. Dinslage, S. Roters, P. C. Jacobi, P. Walter, and G. K. Krieglstein, "Signal quality of biometry in silicone oil-filled eyes using partial coherence laser interferometry," J. Cataract Refract Surg. 31, 1006-10 (2005). https://doi.org/10.1016/j.jcrs.2004.09.049
  16. W. Li, X. Lu, and Y. Lin, "Novel absolute displacement sensor with wide range based on malus law," Sensors(Basel) 9, 10411-22 (2009).
  17. I. Damian, "Malus' law for a real polarizer," arXiv preprint physics/0604073 (2006).
  18. K. Irsch and A. A. Shah, "Birefringence of the central cornea in children assessed with scanning laser polarimetry," J. Biomed Opt. 17, 086001 (2012). https://doi.org/10.1117/1.JBO.17.8.086001
  19. R. N. Weinreb, C. Bowd, D. S. Greenfield, and L. M. Zangwill, "Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry," Arch Ophthalmol. 120, 901-6 (2002). https://doi.org/10.1001/archopht.120.7.901
  20. R. W. Knighton and X. R. Huang, "Linear birefringence of the central human cornea," Invest Ophthalmol. Vis Sci. 43, 82-6 (2002).