• 제목/요약/키워드: Casts

검색결과 387건 처리시간 0.023초

Hinge Axis Point에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE HINGE AXIS POINT)

  • 조인호
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.11-16
    • /
    • 1976
  • Casts are often transferred to the articulator by arbitrary means, because the method of locating the true hinge axis point thought to be a complicated and time consuming procedure, and because the importance and significance of the true hinge axis in the construction of dental prosthesis is not sufficiently understood. In this report, the author constructed the hinge axis locator and determined the variations in location of the true hinge axis points from the location of the hinge axis point determined by arbitrary means. For this report, the procedure was followed on 50 persons with normal occlusion and sound T.M.J. function, so 100 true hinge axis points were recorded and compared with the arbitrary hinge axis point. The results obtained were as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right; (O)5.17mm., (V)3.44mm., (H)3.55mm.. Left; (O)5.63mm., (V)3.95mm., (H)3.51mm.. 2. The percentage of true hinge axis points classified at intervals of 2mm was as follows. 0-2mm; 4%, 2-4mm; 21%, 4-6mm; 37%, 6-8mm; 26%, 8-10mm; 10%, Over 10mm; 2%. And only 50% of the 100 true hinge axis points were located within a 5mm. radius of the arbitrary hinge axis point. 3. Instead of transferring the casts to the articulator by arbitrary means, the careful location of the true hinge axis points is recommended to avoid potential sources of error in mounting casts.

  • PDF

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구 (WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구 (A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

Maxillomandibular arch width differences at estimated centers of resistance: Comparison between normal occlusion and skeletal Class III malocclusion

  • Koo, Yun-Jin;Choi, Sung-Hwan;Keum, Byeong-Tak;Yu, Hyung-Seog;Hwang, Chung-Ju;Melsen, Birte;Lee, Kee-Joon
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.167-175
    • /
    • 2017
  • Objective: To evaluate the differences in maxillomandibular transverse measurements at either the crown or the estimated center of resistance (CR), and to compare values between normal occlusion and Class III malocclusion groups. Methods: Dental casts and computed tomography (CT) data from 30 individuals with normal occlusion and 30 with skeletal Class III malocclusions were evaluated. Using the casts, dental arch widths (DAWs) were measured from the cusp tips, and basal arch widths (BAWs-cast) were measured as the distance between the points at the mucogingival junction adjacent to the respective cusp tips. The BAWs determined from CT (BAWs-CT) images were measured from the estimated CRs of the teeth. Results: None of the DAW measurements or maxillomandibular DAW differences showed statistically significant intergroup differences. In contrast, the maxillary BAWs-CT and BAWs-cast were lesser in the Class III malocclusion group than in the normal occlusion group. The mandibular BAWs-CT were significantly greater in the Class III malocclusion group than in the normal occlusion group. Moreover, the maxillomandibular BAW differences on both CT and cast showed significant intergroup differences in all transverse measurements. Conclusions: The maxillomandibular DAW differences showed no significant intergroup differences. In contrast, the maxillomandibular BAW differences on both CT and cast showed significant intergroup differences in all transverse measurements. The maxillomandibular BAW differences at the estimated CRs, measured using CT or casts, can reveal underlying transverse maxillary basal arch deficiencies in patients with skeletal Class III malocclusions.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향 (Effect of interproximal undercut on the dimensional accuracy of impression)

  • 이주리;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.330-336
    • /
    • 2015
  • 목적: 본 연구의 목적은 치간 유두의 소실로 인해 치아 사이에 언더컷이 존재하는 경우 이것이 인상체의 정확도에 영향을 미치는지 알아보고자 하는 것이다. 재료 및 방법: 2종류의 부가중합형 실리콘 인상재($Extrude^{(R)}$ Wash, $Imprint^{TM}$ II Quick Step Light Body)와 한 종류의 알지네이트 인상재(Cavex Impressional)로 상악 주모형의 인상을 채득하여 얻은 실험모형상의 두 점 사이의 거리를 측정하여 주모형과 비교하여 모형의 변형 정도를 측정하였다. 세 종류의 인상재에서 얻은 실험 모형들을 치간 유두가 존재하는 군과 존재하지 않는 군으로 나눠 총 6개의 군을 평가하였으며, 각 군당 6개의 모형을 측정하였다. 삼차원 광학 스캐너로 실험모형을 스캔한 후, 하나의 모형당 6개의 두 점 사이의 거리를 삼차원 디지털 계측 소프트웨어 상에서 측정하였다. 측정 거리의 변화 정도를 백분율로 계산하여 모형의 변형률을 구하였으며, 이것을 이원분산분석을 이용하여 유의수준 .05에서 분석하였다. 결과: 측정거리 6개 중 3개에서 인상재에 따라 통계적으로 유의한 차이를 보였다. 반면, 치간 유두의 존재 여부에 따른 차이는 알지네이트 인상재에서 하나의 측정 거리에서만 유의한 차이를 보였을 뿐(P=.047), 다른 측정거리들과 인상재에서는 통계적으로 유의성 있는 차이를 나타내지 않았다. 결론: 치간 유두의 소실로 인한 언더컷의 존재가 부가중합형 실리콘 인상재와 알지네이트 인상재의 체적 정확도에 미치는 영향은 크지 않았다.