• 제목/요약/키워드: Casting machine

검색결과 176건 처리시간 0.03초

The effect of repeated porcelain firings on corrosion resistance of different dental alloys

  • Tuncdemir, Ali Riza;Karahan, Ismail;Polat, Serdar;Malkoc, Meral Arslan;Dalkiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.44-50
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS. Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at ${\alpha}$=0.05. RESULTS. The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). Conclusion. Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.

ABOw/AC4CH의 바인더 종류에 따른 파괴인성 및 미끄럼마모 특성 (Fracture Toughness and Slinding Wear Properties of ABOw/AC4CH by Binder Additives)

  • 박원조;정재욱;최용범;이광영
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.373-378
    • /
    • 2002
  • Metal matrix composites have a great interest in recent years because high specific strength, high specific stiffness characteristics, and application ranges of the composites are extend to variety industry. In this paper, an investigation was performed on the plane strain fracture toughness and slinding wear properties of AC4CH alloy(Al-Si-Mg line) reinforced with 20wt% aluminum borate whisker expect one, which contained a inorganic binder($TiO_2$). the binder led to the formation of strengthen the whisker each other. The test of fracture toughness was using CT(half size) specimen of thickness 12.5mm, width 25mm. and test of slinding wear of using tribo a pin-on-disk machine and lubricant is used without paraffine 8.2CST at room temperature. As results, Fracture toughness $K_{IC}$ is $8.7MPa-m^{05}$ for ABOw/AC4CH, $9.28MPa-m^{05}$ for ABOw/AC4CH added $TiO_2$. but AC4CH alloy was violated the critical stipulated by ASTM standard for valid measurement of $K_{IC}$. In case of, it was performed $J_{IC}$ test instead of $K_{IC}$ based on ASTM E 1820.

  • PDF

Computer Simulation for Die Filling Behavior of Semi-Solid Slurry of Mg Alloy

  • Lee, Dock-Young;Moon, Jung-Hwa;Seok, Hyun-Kwang;Kim, Sung-Bin;Kim, Ki-Bae
    • 한국주조공학회지
    • /
    • 제27권1호
    • /
    • pp.31-35
    • /
    • 2007
  • 본 연구에서는 Mg합금의 반응고성형 공정기술을 개발하기 위하여 여러 가지 전단속도와 냉각속도에 따른 Mg합금의 점도와 딕소트러픽 거동을 분석하였으며, 이를 전산모사연구와 비교 검토하였다. 전산모사연구에서는 미세조직과 공정변수를 고려한 반응고 슬러리의 유변학적 거동을 분석하였다. 반응고 온도영역에서의 Mg합금(AZ91D) 슬러리의 점도는 고상율에 따라 지수함수적으로 증가하였으며, 전단속도가 증가하면 감소하는 경향을 나타났다. Mg합금 슬러리의 유변학적 거동을 정확하게 분석하기 위하여 Carreau 모델을 사용하여 ANYCAST 프로그램에서 고압다이캐스팅용 금형으로의 Mg합금 반응고 슬러리의 충진거동을 모사하였다. 전산모사된 결과는 동일한 조건에서의 실제 실험결과와 잘 일치하였다.

투명한 폴리이미드 공중합체 필름의 합성과 특성 연구 (I) (Synthesis and Characterization of Transparent Copolyimide Films (I))

  • 박종수;장진해
    • 폴리머
    • /
    • 제32권6호
    • /
    • pp.580-586
    • /
    • 2008
  • 4,4'-(Hexafluoroisopropylidene) diphthalic anhydride (6FDA) 와 1,3-bis (3-aminophenoxy) benzene(BAPB)의 조성에 2,2-bis [4-(4-aminophenoxy)phenyl] hexafluoropropane (BAPP)를 다양한 몰 비에 따른 폴리이미드(PI) 공중합체를 합성하였다. PI 공중합체 필름들은 여러 열처리 과정을 통하여 용액 캐스팅 (solution casting)된 폴리아믹산(PAA)으로부터 얻었다. 퓨리에 변환 적외선 분광기(FT-IR), 넓은 각 X-선 회절(XRD), 전계 방사형 주사 전자 현미경(FE-SEM) 시차 주사 열량계(DSC)와 열 중량 분석기(TGA), 만능 인장 시험기 (UTM) 그리고 자외선-가시광선 흡광도기 (UV-Vis. spectrometer) 등을 사용하여 PI 공중합체 필름의 열적 기계적 성질, 모폴로지 및 광학 투명도를 측정하였다. PI 공중합체 필름의 유리전이온도 및 최종 강도와 초기 탄성률은 BAPP의 몰 비가 증가할수록 증가하였으나, 초기분해온도는 BAPP의 몰 비 증가에 무관하게 일정하였다. BAPP가 charge transfer complex를 형성하는 이유로 BAPP 농도가 증가함에 따라 PI 공중합체 필름의 투명도는 약간씩 감소하였다.

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究) (A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA)

  • 장익태;양재호;김창회;김광남;이선형;김영수;장완식
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

수종의 세멘트에 따른 주조금관의 유지력 및 세멘트 두께의 비교 (COMPARISON FOR THE RETENTION OF CASTING CROWN AND CEMENT THICKNESS FOLLOWING VARIOUS CEMENTS)

  • 이청희;조광헌
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.37-46
    • /
    • 1994
  • 주조관에 대한 레진 세멘트의 유지력을 알아보기 위하여 상악소구치 30개를 일정한 크기로 삭제한 다음통상적인 방법으로 비귀금속 주조관을 제작한후, 각 군에 10개씩 나눈 후 I군에서는 인산 아연세멘트, II군에서는 Panavia-EX, 그리고 III군에서는 All-Bond & composite resin cement로 5kg의 정적인 압력하에서 세멘트한 후, 인스트론 만능시험기에서 cross head speed 1mm/min으로 유지력을 측정하였다. 레진 세멘트의 세멘트 두께를 측정하기 위해서 하나의 상악 소구치를 치아 형성한 후 인상을 채득하여 비귀금속의 치아 5개를 만들고 여기에서 각각의 비귀금속 주조관을 만든 후각 시편의 협, 설, 근, 원심 4면에 변연 가까이 표식을 만든 후, 세멘트하기전 및 Panavia-EX, All-Bond, 인산 아연 세멘트의 순으로 세멘트한 후의 주사전자 현미경 사진을 채득하여 세멘트 후의 두 표시 사이의 간격에 세멘트 하기 전의 간격을 제한 후 한 시편의 4면에서 나온 간격을 평균하여 그 해당 세멘트의 해당 시편에서의 세멘트 두께로 하여 5개의 시편에서 각각 세멘트의 세멘트 두께를 측정하였다. 1. III군에서 $4.34{\pm}1.08kg$으로 가장 파단하중이 높았고 II군에서 $3.34{\pm}1.22kg$, I군에서 $1.66{\pm}0.4kg$의 순으로 나타났다. 2. III군은 I군과 II군에 대해, 그리고 II군은 I군에 대해 통계학적 유의성 있는 차이를 나타내었다(p<0.05). 3. 세멘트 두께에 있어서 Z.P.C는 $45.4{\pm}16.6m$, Panavia는 $41.3{\pm}22.9m$, 그리고 All-Bond는 $151{\pm}82m$로 나타났다. 4. 인산 아연 세멘트와 Panavia는 All-Bond에 대해 통계학적 유의성 있는 차이를 나타내었으며(p<0.05)인산 아연 세멘트와 Panavia-EX사이에는 유의성 있는 차이가 없었다(p>0.05).

  • PDF

코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과 (The Effect of Titanium on the Castability of Cobalt-Chrome Alloy)

  • 유수경;정희정;방몽숙;양홍서;임현필;윤귀덕;박상원
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.73-79
    • /
    • 2011
  • 연구의 목적은 타이타늄이 함유된 코발트 크롬의 주조성에 타이타늄이 어떠한 영향을 미치는지 평가하기 위함이다. 원재료에는 코발트, 크롬, 몰리브덴, 실리콘, 망간, 탄소, 질소, 티타늄이 사용되었고 이것들을 정량계량하였다. $Biosil^F$ (Degudent, Germany)를 대조군으로 하였고, 실험군에는 티타늄을 1 wt% 에서 4 wt% 까지 각기 다른 함량으로 첨가하여 주조성을 평가하였다. 왁스 패턴은 $30{\times}40$ cm 크기의 직사각형 모양으로, 총 160개의 격자를 함유하고 있다. 원심주조기 (Neutrodyne Easy Ti: Manfredy)를 사용하여 왁스패턴을 주조하였다. 주조성의 평가는 왁스패턴의 4면이 완전한 격자의 수를 육안과 X-ray를 이용하여 검사하였다. 1 wt%에서 3 wt%의 티타늄을 함유한 금속은 대조군과 비슷한 주조성을 나타냈다. 4 wt%의 티타늄을 함유한 금속은 좋지 않은 결과를 보였다. 4 wt% 미만의 티타늄 함유한 실험군의 주조성은 대조군과 비슷하면서도 기계적인 물성은 증가됨을 보였으며 임상에서의 성공적인 사용을 가능케 한다.

유도무기용 소형 정밀부품 제조공법 개선에 관한 연구 (A Research on the Manufacturing Process Improvement of High-Precision Parts for Precision Guided Missile)

  • 김규영;서정화;김경록;김보람
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.1-9
    • /
    • 2020
  • 국내 유도무기 분야의 비약적 발전에도 불구하고, 유도무기 내 정밀 기계 부품의 제조 방식은 80년대의 기계 절삭가공 및 정밀주조 방식에서 눈에 띄는 발전이 없는 상황이다. 생산 수량이 많지 않고 높은 신뢰도를 요구하는 만큼 기계 절삭가공이나 정밀주조 방식이 유리한 측면이 있는 것은 분명하다. 하지만 광범위 지역 제압용 유도무기(천무, 해룡 등)의 경우 유도탄 1기당 수백 개 이상의 자탄이 소요되어 대량 생산성을 요구하고 있으며, 각각의 부품 중 가공 난이도가 높은 경우는 기존의 기계 절삭가공 및 정밀주조 방식으로는 생산성과 품질을 동시에 충족시키기 어려운 실정이다. 특히 최근에 대두되고 있는 국내 방산제품들의 해외 시장 수출 경쟁력 강화를 위해서는, 생산성의 개선을 통한 원가 절감이 필수적이라고 할 수 있다. 본 연구에서는 상기에 언급된 문제의 해결을 위해 유도무기 소형 정밀부품의 MIM(Metal Injection Moulding) 공법 적용 가능성에 대해 연구한다. MIM 공법의 기초연구를 수행하여 공정 설계 간 최적의 공정 조건을 도출하였으며, 이를 적용하여 제작된 자탄신관 소형 정밀부품과 기존 방식으로 제작된 제품의 품질 검사 결과 비교 및 해당 부품이 적용되어 제작된 신관의 기능시험 수행 결과를 통해 MIM 공법의 적용 가능성을 소개한다.

IN VITRO STUDY OF THE TENSILE BOND STRENGTH OF CEMENT-RETAINED SINGLE IMPLANT PROSTHESIS BY THE VARIOUS PROVISIONAL LUTING CEMENTS AND THE SURFACE TREATMENT OF ABUTMENTS

  • Lee, Hwa-Yeon;Lee, Ho-Sang
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.296-305
    • /
    • 2002
  • The main disadvantage of cement-retained implant restorations is their difficulty in retrievability. Advocates of cemented implant restorations frequently state that retrievability of the restoration can be maintained if a provisional cement is used. The purpose of this study was to find the optimal properties of provisional luting cements and the surface treatment of abutments in single implant abutment system. 30 prefabricated implant abutments, height 8mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were obtained. Three commercially available provisional luting agents which were all zinc oxide eugenol type ; Cavitec, TempBond and TempBond NE were evaluated. No cement served as the control. TempBond along with vaseline, a kind of petrolatum (2:1 ratio) was also evaluated. Ten out of thirty abutments were randomly selected and abutment surfaces were sandblasted with $50{\mu}m$ aluminum oxide. Another ten abutments were sandblasted with $250{\mu}m$ aluminum oxide. A vertical groove, 1 mm deep and 5mm long was cut in each twenty abutments. Ten of them were sandblasted with $50{\mu}m$ aluminum oxide. The full coverage casting crowns were cemented to the abutments with the designated provisional luting agent. Specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Each specimen was attached to a universal testing machine. A crosshead speed of 0.5mm/min was used to apply a tensile force to each specimen. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Tensile bond strength of provisional luting cements in no surface treatment decreased with the sequence of TempBond NE, TempBond, Cavitec, TempBond with vaseline, no cement. 2. Tensile bond strength more increased by surface treatment. Sandblasting with $250{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in the abutment cemented with TempBond NE and sandblasting with $50{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in cemented with TempBond. 3. In the aspect of a groove formation, tensile bond strength significantly increased in TempBond with vaseline only and the others had no significant effect on tensile bond strength.