• 제목/요약/키워드: Casting machine

검색결과 176건 처리시간 0.019초

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

고속회전시험기를 활용한 가스터빈 동익의 내구성 시험 (Spin Testing for the Endurance Verification of Gas Turbine Blades)

  • 이두영;김두수;손태하;구재량
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.19-24
    • /
    • 2018
  • 가스터빈 동익에 대한 지속적인 국산화 개발이 추진되어, 국내 정밀 주조 기술을 향상시키고, 동익의 유지 보수 비용을 낮추는 등의 직간접적인 긍정적 효과를 가져왔지만, 여전히 국산화 개발품이 발전소에서 안정적인 실사용이 가능한지에 대한 우려가 존재한다. 향상된 소재와 주조기술을 바탕으로 조직학적, 기계적 성질에서 충분한 품질을 확보하였더라도, 개발품을 대상으로 다양한 신뢰성 검증이 요구되는 이유이다. 고속회전시험기는 로터, 디스크 등의 회전체에 원심력을 가하여, 이에 따른 제품의 특성을 분석하기 위한 시험장비로 일반적으로 과속도시험을 통한 최종적인 품질검사에 주로 사용된다. 본 논문에서는 전력연구원에 구축된 고속회전시험기를 활용한 가스터빈 동익에 대한 과속도시험을 포함한 저주기피로시험 사례를 중심으로 신뢰성 시험 및 평가 결과를 기술하였다.

CAD/CAM을 이용하여 제작한 All-ceramic core의 변연 적합도 (ON THE MARGINAL FIDELITY OF ALL-CERAMIC CORE USING CAD/CAM SYSTEM)

  • 김동근;조인호;임주환;임헌승
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.20-34
    • /
    • 2003
  • Novel methods producing supplementary and prosthetic material by cutting or discharge processing via computer design have been proposed as alternatives for traditional casting methods and are being utilized for commercial purposes. The CAD/CAM system used in dentistry can be classified into three-dimensional input of target values, restoration design, and material processing. The marginal fidelity in production of In-Ceram core has important clinical implications and is a key consideration issue in CAD/CAM production as well. Through this research, the author arrived at the following conclusion aaer conducting comparison analysis of marginal fidelities between the In-Ceram core produced via CAD/CAM and that produced through the traditional method ; 1. In the cases of mesial, distal, and lingual margins, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 2. In the case of labial flange, the core margins via CAD/CAM produced lower values than those via the traditional method and the differences were found to be statistically significant. (p<0.05) 3. In comparision with overall marginal fidelity, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 4. Among the core margins produced via the traditional method did not have statistically significant differences but fir those produced via CAD/CAM had statistically significant differences between labial and lingual sides and between labial and mesial sides. (p <0.05).

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

광고를 통해 본 일제강점기 치과 장비 및 기구 광고에 관한 연구 (The study on advertisement of dental devices & instrument during Japanese colonized period)

  • 신재의
    • 대한치과의사협회지
    • /
    • 제48권12호
    • /
    • pp.893-918
    • /
    • 2010
  • This article is purposed of reviewing the development history of Japanese dental devices and instrument, and their related advertisement activities during the Japanese colonized period in Korea in early 20th century. Japanese dental devices and instrument were redesigned to accommodate their ergonomic shape above the simple imitation, and it implies the excessive desires brought them frustrations. The tragic earthquake on Sep. l, 1923, medical insurance law enforcement on Jan. 1, 1927, celebration of "Cavity prevention Day" started on Jun. 4, 1928, and the attack of Manchuria and China by Japan after 1931, all of these historical incidents become the preliminary requirement for the development of dental devices. On Nov. 1, 1937, Japanese government started to control dental materials, driving the campaigns for excluding foreign products and encourging the use of local products. In 1939, Nakajima dental manufacturers used this political and social atmosphere on their advertisement as saying "Our Nakajima's products have no compromise with the short raw materials, but only commitment to our quality". Since after 1940, the price and supply have been strongly under control, and the control group was appeared to manage all of supply and distribution of raw materials, regular price system, and specifications. At last, the Japanese national power were devastated in its production and distribution capacities, and get to the frustrated period. The main advertised dental devices and instruments in Korea during the Japanese colonized period were 1) dental chair, unit and cabinet, 2) dental x-ray, 3) compressors, 4) dental needles, 5) small instrument and carryon medical(emergency) kit, 6) oral hygiene and pyorrhea alveolaris, infrared rays, sunlight lamp, ultrashort wave treatment devices, 7)crown former, electric furnace, casting machine, articulator, electric lathe, and laboratory equipments, etc.

치기공과 실습 중 안전사고 실태 조사 Ⅰ (Accidents research Ⅰ for the college students in their Dental Laboratory Technology-major classes)

  • 박종희
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.115-129
    • /
    • 2005
  • The purpose of this study was to identify injury characteristics happened in the college dental laboratory technique classes and to provide the empirical accident findings for safety education development for the college dental technology classes. The research data were collected from a self-administered survey distributed to the conveniently selected college students. The study participants were 476 freshmen, sophomore and junior students whose major was the dental laboratory technology of the 4 colleges in 2 metropolitan cities and 2 medium-size cities. All collected survey responses were encoded and analyzed in SPSS 12.0. The findings were as follows. The accidents happened to the college students during the dental laboratory technology classes: 1. The accident rate was the highest in the sophomore and the freshmen, junior in order. 2. The body parts frequently injured were hands, face, eyes, arms, and legs in order. 3. The frequent injury types were cut, burnt, stuck, wound, and suffocated in order. 4. The treatment methods for their accidents were the simple first-aids, no treatment, and the emergency room visits in order. 5. The laboratory training conditions inducing the accidents were significantly frequent under wire-related, and wax-related, iron-related, alcohol-related jobs in order, but not frequent in investing material-related, porcelain-related, resin-related, and agar-related jobs. Polishing was the most accident-prone job explaining 63% of the laboratory accidents and then, model producing, wax patterning, casting, burning, and investing jobs in order. In summary, the college dental laboratory accidents had the certain patterns by the training level and by the material or machine involved in each class. Thus, the planned and organized safety education programs should be produced and investigated for college students before their major laboratory classes.

  • PDF

팔라듐-은 합금 도재소부전장 가공의치의 잔류응력과 변형에 관한 연구 (A STUDY FOR THE MEASUREMENTS OF THE RESIDUAL STRESS AND THE DISTORTIONS IN THE CERAMO-METAL BRIDGE OF Pd-Ag ALLOY)

  • 전영찬;이호용
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.53-78
    • /
    • 1989
  • This study was taken to observe the changes of the residual stress in the alloy and to measure 3 dimensional distortions of the long span ceramo-metal bridge. The materials used in this study were Pors-on 4 (Pd-Ag alloy), and Ceramco and Vita VMK 68 powders. The residual stress of the alloy was measured on the six specimens (dia. 8m/m) by the X-ray diffraction stress analyzer according to the kind of ceramic powder and different measuring stages. And, for the measurement of the distortions, fifteen specimens of the anterior 8-unit ceramo-metal brige were fabricated and subjected to the 3-D coordinate measuring machine. Variables included the 2 kinds of a ceramic powder and the presence or absence of a splint bar at the cast metal framework. The measuring stages in both were after casting, after degassing and after glazing. The following conclusions were obtained : 1. The residual stress of the alloy showed increasing tendency for the tension by the ceramic fusing, but there was not significance. 2. The tendency of the distortions in the cast metal frameworks were decrease of the width, the anterior displacement and sagging. 3. The amount of the distortions at the degassing stage were greater than that at the ceramic fusing stage. 4. The splint bar was effective to control the distortion only at ceramic fusing stage. 5. The sagging distortion in the Ceramco firing were even through all measuring stages, but in the Vita firing, pronounced at degassing stage.

  • PDF

저속 충격하에서의 금속복합재료의 동적 특성 (Dynamic Behaviors of Metal Matrix Composites in Low Velocity Impact)

  • 남현욱;;;한경섭
    • Composites Research
    • /
    • 제12권1호
    • /
    • pp.68-75
    • /
    • 1999
  • 본 연구에서는 저속 충격에서 충격 속도에 따른 금속복합재료의 동적 거동을 연구하였다. 시험에 사용된 재료는 모재로 AC8A와 보강재로 알루미나($Al_2O_3$)와 탄소를 사용하였으며 용탕 주조법을 이용하여 금속복합재료를 제조하였다. 금속복합재료에는 15%의 부피분율을 가진 알루미나 예비성형체와 알루미나와 탄소를 각각 12%와 3% 사용한 혼합 에비성형체가 사용되었다. 제조된 금속복합재료는 인장 시험과 진동 시험을 통해 인장 강도와 탄성계수를 구하였으며, 저주파 여파기(low pass filter)와 계장화 충격 시험기를 이용하여 충격 속도에 따른 금속복합재료의 충격 거동을 연구하였다. 저주파 여파기를 이용함으로써 충격 속도에 관계없이 안정적인 실험치를 확보할 수 있었다. 충격 속도의 증가에 따라 모재와 금속복합재료의 충격에너지는 증가하였으나, 동적인성치는 일정한 값을 보였다. 충격 속도가 증가할수록 충격에너지 중 균열전파에너지의 향상이 두드러졌으며, 재료의 변형량이 증가하였다. 충격에너지 중 균열개시에너지와 동적파괴인성치의 관계를 설명하기 위하여 변형율 에너지와 노치에서의 응력 분포를 이용하여 간단한 모델을 제시하였으며, 이로부터 균열개시에너지는 동적 파괴 인성치의 자승에 비례하고 탄성계수에 반비례하는 것을 보였다.

  • PDF

TiO2 광촉매를 함유한 PET와 나일론 6 나노복합체막의 자외선/오존에 대한 안정성 (The UV/Ozone Stability of PET and Nylon 6 Nanocomposite Films Containing TiO2 Photocatalysts)

  • 진성우;장진호
    • 한국염색가공학회지
    • /
    • 제26권2호
    • /
    • pp.88-98
    • /
    • 2014
  • This study is to assess the photocatalytic degradation of PET and Nylon 6 films containing nano-sized $TiO_2$ powders of anatase and rutile types. The PET and Nylon 6 films containing six kinds of the nanoparticles were prepared by melt casting method using a heating press machine. Reflectance in visible region and water contact angles of the irradiated PET and Nylon 6 composite films decreased with increasing UV/$O_3$ irradiation. Also the enhanced hydrophilicity has a close relationship with the increase in the Lewis base parameter, which indicates more oxidized polymer surfaces. The photocatalytic degradation of the nanocomposite films increased with increasing $TiO_2$ content and UV energy, which is more significant with the anatase types rather than the rutile types. The amide linkages in the Nylon 6 seemed to be more susceptible to the UV light compared to the ester groups in the PET, particularly in the presence of the $TiO_2$ photocatalysts. The photoscission and photodegradation of the polymers in the composites produced more degraded structure assisted by the photocatalytic activity of the $TiO_2$ nanoparticles. Also the composite films can bleach the methylene blue dyes more easily under the UV/$O_3$ irradiation, suggesting the photobleaching activity of the $TiO_2$ nanoparticles.

Nanocrystallization of Cu-Based Bulk Glassy Alloys upon Annealing

  • Pengjun, Cao;Dong, Jiling;Haidong, Wu;Peigeng, Fan;Anruo, Zhou
    • Applied Microscopy
    • /
    • 제46권1호
    • /
    • pp.32-36
    • /
    • 2016
  • The Cu-based bulk glassy alloys in Cu-Zr-Ti-Ni systems were prepared by means of copper mold casting. The Cu-based bulk glassy alloys samples were tested by X-ray diffractomer (XRD), differential scanning calorimeter, scanning electron microscopy (SEM), Instron testing machine and Vickers hardness instruments. The result indicated that the prepared Cu-Zr-Ti-Ni alloys were bulk glassy alloys. The temperature interval of supercooled liquid region (${\Delta}T_x$) was about 45.48 to 70.98 K for the Cu-Zr-Ti-Ni alloy. The Vickers hardness was up to 565 HV for the $Cu_{50}Zr_{25}Ti_{15}Ni_{10}$ bulk glassy alloy. The $Cu_{50}Zr_{25}Ti_{15}Ni_{10}$ bulk glassy alloys were annealed in order to obtain nanocrystals. The results showed that the Vickers hardness was raise up to 630 HV from 565 HV. As shown in XRD results, the amorphous alloys changed to nanocrystals, which were $Cu_8Zr_3$, $Cu_3Ti_2$ and CuZr, improved the hardness. The SEM analysis showed that the compression fractured morphology of amorphous alloys was brittle fracture, and the fracture morphology after annealing was ductile fracture. This proved that annealing of amorphous to nanocrystals can improve the plasticity and toughness of amorphous alloys.