• Title/Summary/Keyword: Cassette

Search Result 354, Processing Time 0.025 seconds

Development of Seismic Recorder for Long-term Observation of Microearthquakes (미소지진(微小地震) 장기관측(長期觀測)을 위한 지진기록계(地震記錄計)의 개발(開發))

  • Kim, Sung Kyun;Cho, Kyu Jang;Chung, Bu Heung;Moon, Chang Bae;Sin, In Chul;Sung, Rack Hoon
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.185-191
    • /
    • 1988
  • A two channel seismic recorder suitable for long-term observation of microearthquakes is developed. The direct analogue recording on cassette tape is adopted in the recorder whose circuits of amplifier and mortor units of an audio cassette recorder are modified. The recorder provides contineous record of 10 days with DC 12V battery (100AH) and with standard cassette tape of 60 minute use. The binary coded time signals of date, hour, and minute are generated once a minute by the timing system and absolute time input using radio to measure the time drift is also possible. For the seismic signal processing, the analogue signals from audio cassette player pass A/D converter and digitized data are stored in personal computer. Then visual records can be obtained using computer graphic mode. Basic programs "ADCONVO" and "DRAWO" to accomplish A/D conversions, the creation of data files and visualization of signals were written. Some sample signals reproduced from the recorded tape are presented.

  • PDF

Characterization of Total and Size-Fractionated Manganese Exposure by Work Area in a Shipbuilding Yard

  • Jeong, Jee Yeon;Park, Jong Su;Kim, Pan Gyi
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.150-155
    • /
    • 2016
  • Background: Shipbuilding involves intensive welding activities, and welders are exposed to a variety of metal fumes, including manganese, that may be associated with neurological impairments. This study aimed to characterize total and size-fractionated manganese exposure resulting from welding operations in shipbuilding work areas. Methods: In this study, we characterized manganese-containing particulates with an emphasis on total mass (n = 86, closed-face 37-mm cassette samplers) and particle size-selective mass concentrations (n = 86, 8-stage cascade impactor samplers), particle size distributions, and a comparison of exposure levels determined using personal cassette and impactor samplers. Results: Our results suggest that 67.4% of all samples were above the current American Conference of Governmental Industrial Hygienists manganese threshold limit value of $100{\mu}g/m^3$ as inhalable mass. Furthermore, most of the particles containing manganese in the welding process were of the size of respirable particulates, and 90.7% of all samples exceeded the American Conference of Governmental Industrial Hygienists threshold limit value of $20{\mu}g/m^3$ for respirable manganese. Conclusion: The concentrations measured with the two sampler types (cassette: total mass; impactor: inhalable mass) were significantly correlated (r = 0.964, p < 0.001), but the total concentration obtained using cassette samplers was lower than the inhalable concentration of impactor samplers.

A Study on the Mold System of Bicycles Gear for Driving Safety (주행 안전을 위한 자전거 기어의 프레스금형에 관한 연구)

  • Jeong, Youn-Seung
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • Recently, bicycle has means of effective healthy transportation, and riding the bicycles is considered as popular recreational and sporting activities. Also, the saddle, steering system, driving device and braking device are researched briskly because of consumer's need for driving performance and comfort. Especially, the importance of a cassette responsible for transmission function by transmitting power to the drive shaft through the chain is very focused. The writer conducted structural analysis for the sprocket of each level using the ANSYS widely used for the analysis. Speed shifting performance was enhanced by minimization / simplification of shifting point through a sort of tooth profile of the cassette. By partitioning a clear value type and other shifting point, it has been modified to enable smooth speed-shifting. In addition, as titanium precision forming process, this study studied the molding technique by blanking and dies forging for mass production of the cassette. so it could be expected that the entire drive train would utilize that in the future. The stamping process capability for thin materials for the mass production of the sprockets is applicable to producing automobile parts, so lightweight component production is likely to be possible through that, for the safety of driving.

A Numerical Study on Flow Field near the Roller Conveyor for Flat Panel Display (평면 디스플레이 기판 운송용 롤러 컨베이어 주위의 유동장에 관한 수치해석 연구)

  • Jeon, Hyun-Joo;Kim, Hyoung-Jin;Im, Ik-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

Pollution Research about Radiology radiographic laboratory (방사선 영상학 실습실 오염실태 조사 (D대학교 DR장비와 방사선 발생장치, Cassette 오염실태 조사))

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.69-76
    • /
    • 2013
  • We checked the existence of bacteria at DR equipment, radiation generator and cassette in 'D university' to propose optimized management method for bacteria and disinfection at DR equipment, radiation generator and cassette at used in radiographic laboratory of the department of radiology. The infected region is treated by alcohol and cresol and compared before spraying and after spraying for 1, 3, 5 and 10 minutes. As time goes on, amount of bacteria colony decreases significantly. The Cresol is useful to disinfect the diminutive devices. However alcohol disinfection, at least 5 minutes later, and hand washing before practical training and shooting image is recommended due to the big and fixed radiography equipment which cause the soakage.

  • PDF

Comparison of Area vs Personal Total Dust Concentrations Measured by 37mm Closed-face Cassette and IPM Sampler (목재분진 농도 측정에 대한 37 mm closed-face 카세트법과 IPM 측정법 비교)

  • Lee, Dong-won;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 1996
  • This study was performed to estimate total dust concentrations and particle size distribution of wood dust in the furniture and sawmill industries. To compare total wood dust concentrations, two samplers recommended by the American Conference of Governmental Industrial Hygienists and by the National Institute for Occupational Safety and Health were used. Concentration data were analyzed by paired-t tests using the SAS program and two parameters of the particle size distributions were determined by histogram. The results were as follows: 1. Particle size distributions showed a unimodal pattern in cutting and a bimodal in sanding operations. Mass median aerodynamic diameters(MMAD) were $17.35{\mu}m$ in cutting, and $1.39{\mu}m$ for small mode and $18.89{\mu}m$ for large mode in sanding operations. The proportions of particle size larger than $9.8{\mu}m$ estimated by the impactor were 61.16 % in cutting and 62.33 % in sanding operations, respectively. 2. The average personal total dust concentrations measured by IPM sampler were $17.12mg/m^3$ (GSD=1.45) from indoor samples, $2.97mg/m^3$(GSD=1.90) from outdoor samples in cutting, and $8.01mg/m^3$(GSD=1.58) from sanding operation. And those of by 37 mm closed-face cassette were $9.12mg/m^3$(GSD=1.46), $1.06mg/m^3$(GSD=1.99) from cutting, and $3.32mg/m^3$(GSD=2.16) from sanding operations. 3. The average area total dust concentrations measured by IPM sampler were $1.88mg/m^3$(GSD=2.04) from indoor cutting, $4.76mg/m^3$(GSD=2.83) from indoor sanding operations. And those of by 37mm closed-face cassette were $0.49mg/m^3$(GSD=2.34) from cutting, and $1.32mg/m^3$(GSD=3.03) from sanding operations. 4. The ratio of personal total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 35.7 %, 53.3 % from cutting, and 41.4 % from sanding operations. 5. The ratio of area total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 26.1 % from cutting, and 27.7 % from sanding operations. 6. A statistically significant difference of total dust concentrations between the 37 mm closed-face cassette and the IPM sampler was found.

  • PDF