• Title/Summary/Keyword: Cartridge

Search Result 499, Processing Time 0.026 seconds

Comparison of the trometamol-balanced solution with two other crystalloid solutions for fluid resuscitation of a rat hemorrhagic model

  • Ting, Wen-Ting;Chang, Ru-Wen;Wang, Chih-Hsien;Chen, Yih-Sharng;Lee, Jih-Jong
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.6.1-6.12
    • /
    • 2020
  • Currently, the optimal resuscitation fluid remains debatable. Therefore, in the present study, we designed a trometamol-balanced solution (TBS) for use as a resuscitation fluid for hemorrhagic shock. Hemorrhagic shock was induced in 18 male Wistar-Kyoto rats, which were assigned to normal saline (NS), Ringer's solution (RS), and TBS groups. During the hemorrhagic state, their hemodynamic parameters were recorded using an Abbott i-STAT analyzer with the CG4+ cartridge (for pH, pressure of carbon dioxide, pressure of oxygen, total carbon dioxide, bicarbonate, base excess, oxygen saturation, and lactate), the CG6+ cartridge (for sodium, potassium, chloride, blood glucose, blood urea nitrogen, hematocrit, and hemoglobin), and enzyme-linked immunosorbent assay kits (calcium, magnesium, creatinine, aspartate aminotransferase, alanine aminotransferase, bilirubin, and albumin). Similar trends were found for the parameters of biochemistries, electrolytes, and blood gas, and they revealed no significant changes after blood withdrawal-induced hemorrhagic shock. However, the TBS group showed more effective ability to correct metabolic acidosis than the NS and RS groups. TBS was a feasible and safe resuscitation solution in this study and may be an alternative to NS and RS for resuscitation in hemorrhagic shock patients without liver damage.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

The rapid synthetic strategy of [11C]PIB via disposable column cartridge purification

  • Jihye Lee;Yansheng Li;Sang-Yoon Lee;Tatsuo Ido
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.69-74
    • /
    • 2020
  • PIB is the first amyloid plaque PET image tracer reported for the first time in 2003, and is considered to be the best and is still being utilized due to its very high uptake and kinetic properties. Initially, it was synthesized by radioisotope labeling using a precursor containing a methoxy methyl protection group, but now it is synthesized using a 6-OH precursor that can be easily synthesized in one step using [11C]methyl triflate. Carbon-11 has several limitations in clinical studies using PET because its half-life is as short as 20 minutes. In this study, in order to overcome the difficulty of this half-life, a rapid method using Sep-Pak was adopted instead of HPLC purification to significantly reduce the burden of the purification process and attempted synthesis. As a result, the synthesis time was shortened by more than 50%, and the yield of the final compound was higher than the previous result and showed relatively high specific radioactivity, confirming that it is a strategic method with high applicability for various precursors having primary amines.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Optimum design of injection mold heater for uniform curing of LSR seal for waterproof connector (방수 커넥터용 LSR Seal의 균일 경화를 위한 사출 금형 히터의 최적 설계)

  • Song, Min-Jae;Cha, Baeg-Soon;Hong, Seok-Kwan;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.310-315
    • /
    • 2017
  • Automotive waterproof connectors are highly functional parts that must be air-tight in a complex environment. In the LSR multi-cavity injection molding process for manufacturing waterproof connectors, it is important to maintain a uniform curing temperature between the cavities in order to obtain a quality product. For this purpose, we designed the capacity of the cartridge heater differently for each position, and then linked the heat transfer analysis and optimization module to obtain the optimal cartridge heater capacity. As a result of the optimization analysis, the temperature deviation between cavities was decreased from $13.1^{\circ}C$ to $8.1^{\circ}C$ compared with the case in which constant heater capacity was applied, so that the design criterion could be satisfied within a temperature deviation of $10^{\circ}C$ for uniform curing. This study suggests that this method can be applied efficiently to the design of a large area multi-cavity LSR mold heater.

Case Studies and Future Prospect of Using Bulk Emulsion (에멀젼계 벌크폭약을 이용한 시공사례와 향후 전망)

  • Kim, Hee-Do;Choi, Sung-Hyun
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.64-76
    • /
    • 2008
  • Bulk Emulsion blasts using mechanized charging system, which is generally used in foreign countries, have recently introduced and gradually increased in Korea. The Bulk Emulsion are safe and able to increase the charging density for improvement of fragmentation and advancement especially in tunneling, and minimizing environmental problem. Because of less toxic gas generation, the explosives are called, namely ech-friendly products. There are two kinds of Bulk Emulsion; one is for open cut and the other is for tunneling. According to features of blast sites and its purpose, the compositions are different, but the principle is the same. In this study, trial blasts using Bulk Emulsion for tunneling had executed at 10 sites in Korea. The major result of the major job-sites is the following. First of all, compared with cartridge explosive, Bulk Emulsion was able to increase its charging density up to $35{\sim}60%$, to decrease the blast holes to approximately $10{\sim}30%$ down, and the advancement was improved up to $8{\sim}20%$ and also 30% up in its fragmentation. Toxic gas production after cartridge blasting showed 34.44ppm of its CO. Bulk Emulsion, however, showed 20.13ppm, which was 58.45% production of the cartridge explosive, and NOx was below 2ppm. The mechanized charging system of Bulk Emulsion should be applied to large sized tunnel blasting, long advanced tunnel which can secure the advancement of over $4{\sim}5m$, and the sites required finishing rapidly.

Evaluation of Tar Dyes Used in Commercial Foods (식품 중 합성첨가물 사용실태 조사 연구 -타르색소 중심으로-)

  • 윤미혜;김국주;김정임;황선일;문수경;정은주;김재관
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.2
    • /
    • pp.108-113
    • /
    • 2000
  • This study was carried out to propose a simple method for the extraction of seven tar dyes such as tartrazine, sunset yellow FCF, amaranth, erythrosine, allura red, brilliant blue FCF and indigo carmine using aminopropyl amine cartridge and to determine the content of the dyes in candies, soft drinks, ice bars and okchuns produced in Korea. The tar dyes were simultaneously analyzed by reverse phase high performance liquid chromatography(HPLC). The recovery rates of the dyes ranged from 65.8% to 99.6%. The contents of the dyes in candies, soft drinks, ice bars and octhuns were N.D.∼50.1 mg/kg, N.D.∼49.9 mg/kg, N.D.∼56.0 mg/kg and N.D.∼867.3 mg/kg, respectively. The types of the dyes used most frequently for candies, soft drinks and ice bars were tartrazine, brilliant blue and amaranth, respectively. Of the samples, tartrazine was used frequently, and indigo carmine was not used at all.

  • PDF

The study of analytical method for sulfonamide antibiotics and their metabolites in environmental samples (환경 시료 중 설폰아미드계 항생제 및 대사체 분석방법 연구)

  • Kang, Young-Yeul;Hwang, Seung-Ryul;Shin, Sun-Kyoung;Koo, So-Hyun;Sim, Ki-Tae;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.437-445
    • /
    • 2010
  • The aim of this study was to develop an analytical method for sulfonamide antibiotics (sulfadiazine, sulfamerazine, sulfamethazine, sulfamethoxazole, sulfathiazole) and their metabolites ($N^4$-acetylsulfadiazine, $N^4$-acetylsulfamerazine, $N^4$-acetylsulfamethazine, $N^4$-acetylsulfamethoxazole, sulfamethoxazole-$N^1$-glucuronide) in environmental samples. The solid phase extraction (SPE) with LC/ESI-MS/MS have been used for the analysis of target compounds, and the recoveries of SPE clean-up were at the range of 12-94% for C18 cartridge, 60-95% for HLB cartridge, 25-123% for MCX cartridge, and 70-90% for tandem HLB/MCX. By established method, detection limit, recovery, and relative standard deviation were 0.001~0.187 ng/mL, 66~115%, and 5~17%, respectively. This method was effective and sensitive to use for the simultaneous determination of sulfonamide antibiotics and their metabolites in environmental samples. Four sulfonamide antibiotics were detected at the range of 0.008~2.153 ng/mL. For metabolites, only $N^4$-acetylsulfamethoxazole was detected, but the concentration was under the MDL level.

Non Thermal Process and Quality Changes of Foxtail Millet Yakju by Micro Filtration (미세여과에 의한 비 가열살균 좁쌀약주의 제조 및 저장 중 품질변화)

  • Kang, Young-Joo;Oh, Young-Ju;Koh, Jeong-Sam
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.277-284
    • /
    • 2005
  • Micro-filtration (MF) or ultra-filtration (UF) system with hollow-fiber cartridge was introduced in order to improve the Quality level of commercial foxtail millet Yakju, which has an off-flavour and/or undesired colour after the thermal treatment. The filtration effects of cartridges such as MF (0.65, 0.45, 0.2, 0.1 $\mu$m) and UF (500 K dalton) were investigated. The physicochemical and sensory characteristics of the Yakju were then evaluated during the 6 months storage at room temperature. The exclusion ability of microorganism in samples was confirmed in all cartridges, but 0.45 pm MF-cartridge was suitable in the Yakju manufacture due to its superior filtration rate and efficiency. Changes in reducing sugar and colour difference of foxtail millet Yakju untreated or treated by heat ($65^{\circ}C$${\times}$10 min) were observed during the storage; after 6 months the L-value of thermal-treatment sample was decreased and its b-value, however, significantly increased so that its color became dark, in comparison to non-thermal treatment sample. This decrease of reducing sugar is assumed that color change is associated with non-enzymatic browning reaction. Sensory Quality of foxtail millet Yakju produced by non-thermal treatment was better than that of thermal treatment.

Investigation of Nonylphenols Contamination in Solvents and Solid-phase Extraction Cartridge, and its Removal Protocols (정밀분석용 용매 및 SPE의 Nonylphenols 오염평가 및 제거)

  • Park, Jong-Min;Choi, Geun-Hyonng;Kim, Jung-Im;Hong, Su-Myeong;Kwon, Oh-Kyung;Im, Geon-Jae;Kim, Jin-Hyo
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.1
    • /
    • pp.22-27
    • /
    • 2011
  • Nonylphenols are toxic compounds classified as endocrine disruptors. We investigated the nonylphenols clean-up procedures for the contamination control in the quantitative analysis. In this research we analyzed the residual nonylphenols in the solvent and the SPE cartridges. First, at the analysis of HPLC grade solvents (n-hexane, diethyl ether, ethyl acetate and its mixture), diethyl ether was confirmed the residue as 0.963 ${\mu}g/mL$, and we eliminated the contaminant through the distillation with $CaH_2$, Second, at the analysis of SPE cartridges (silica gel and Florisil), all products were showed the residue at 0.046~13.0 ${\mu}g/mL$, but unfortunately the residue in the cartridge were not easily removed with referenced methods in all tested SPE cartridges except in silica gel SPE cartridge with glass ware.