• Title/Summary/Keyword: Cartridge

Search Result 499, Processing Time 0.036 seconds

Development of New Analysis Method of Cyanobacterial Toxins in Reservoirs (호수에서의 남조류 독성물질의 새로운 분석법 개발)

  • Pyo, Dong Jin;Song, Gi Seop;Yun, Seok Chang;Kim, Beom Cheol;Lee, Dae Un
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.741-748
    • /
    • 1994
  • A new HPLC method for the analysis of cyanobacterial toxins, i.e. microcystin was developed using cyano-type prepacked cartridge while the conventional method was to utilize ODS cartridge. The cartridge was washed with 0.5 M acetic acid, then microcystins RR and LR were eluted from the cartridge with 30% acetonitrile. A better degree of quantitation was observed than with a ODS cartridge. Especially, in the case of microcystin LR a great difference in peak area was observed.

  • PDF

Prediction of Service Life of a Respirator Cartridge for Organic Solvent by Using Yoon and Nelson's Adsorption Model (Yoon과 Nelson의 흡착모델을 이용한 방독마스크 정화통의 수명예측(I))

  • Kim, Ki-Hwan;Won, Jung-Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.20-31
    • /
    • 2008
  • A respirator is useful to protect a worker from the harmful gases and vapors in the workplace, and the evaluation of respirator cartridge service life is important for the worker's health and safety. The performance of cartridge is effected by several factors such as concentration of gas and vapor, humidity, temperature, adsorbents and cartridge packing density. Adsorption model was applied to both sampling tube and respirator cartridge to predict the service life for organic vapors. The variables of the adsorption model were measured from the experiment with the sampling tube, and it was used to predict the service life of respirator cartridge. In the experiment, we used carbon tetrachloride as a organic vapor and activated carbon take out respirator cartridge as activated carbon. As a result, it was possible to predict the service life of respirator cartridge and predicted service life was quite correct. Breakthrough time decreased with increase of CCl4 concentration. In case of sampling tube, adsorbed amount of CCl4 was larger than respirator cartridge due to linear velocity. Also, rate constant of sampling tube was larger than respirator cartridge, because of, effect of flow rate, packing density. In the prediction of service life of respirator cartridge by using sampling tube, the time required for 50% contaminant breakthrough(${\tau}$) is more effective than the rate constant(k').

Separation in Oxdized Mixture of Lipids and Phenolics by Cartridge (Cartridge에 의한 지질과 폐놀물질 혼합산화물의 분리)

  • 김정숙
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.5 no.1
    • /
    • pp.87-93
    • /
    • 1995
  • The oxidized mixture of lipid(methyl linoleate) and phenolics(phloroglucinol) at 37$^{\circ}C$, 82$m\ell$ O/min., for 9 days were separated each by C cartridge and silica cartridge making use of different eluting solvent. And the oxidation products were analyzed by HPLC. In conclusion, the oxidized mixture were separated into methyl linoleate and phloroglucinol by cartridge on HPLC. and also in this experiment, separated methyl linoleate and phloroglucinol could be analyzed in the common eluant, water and acetonitrile on HPLC. SEP-PAK cartridges were used almost sample purification until now, but under the various eluting solvents and conditions, cartridge will be expected to mini columns which can separate different polarity materials.

  • PDF

Prediction of Service Life of a Respirator Cartridge by the Occupational Environment(II) (작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측(II))

  • 김기환;김덕기;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.72-78
    • /
    • 1996
  • The breakthrough curves of a sampling tube were studied to predict the service life of a respirator cartridge for organic vapors. The fixed bed adsorption model was applied to respirator cartridge and it's variables were calculated from tile experiment of sampling tube. By the experiment and simulation, it was possible to predict the service life of a respirator cartridge, however, not adequate at low $CCl_4$ concentration less than 700ppm and at high air humidify. The breakthrough curves of sampling tube were irregular compare to that of respirator cartridge due to .packing density.

  • PDF

Comparison of recovery rates of DNPH-Cartridge sampler in the analysis of odorous carbonyl compounds (DNPH Cartridge를 이용한 악취성 카르보닐화합물의 분석회수율 비교)

  • Hong, One-Feel;Lim, Sung-Min;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.446-456
    • /
    • 2010
  • In this study, the performance characteristics of DNPH sampling were investigated in the collection and analysis of 5 carbonyl compounds (CC) in air using the cartridge products produced by three different makers. For these experiments, gaseous standards of 5 CCs were prepared to cover 9 concentration levels for each compound (33~2600 nmol). Some cartridge products exhibited relatively high blank values of acetaldehyde (AA) and propionaldehyde (PA). The recovery rates of all three cartridges showed moderate reduction as the molecular weight of CC increased. In addition, when the recovery rate was compared by percent error (%), the most stable patterns were achieved in the intermediate concentration range of 263~1312 nmol (in case of AA). The overall results of our study suggest that the optimal range of recovery for a given concentration range should be considered to obtain the most reliable data for the DNPH cartridge method.

Carbon Nanotube Cartridge for the Fabrication of Nanotweezer (나노트위져 제작을 위한 탄소나노튜브 카트리지)

  • 최재성;이준석;강경수;곽윤근;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.146-150
    • /
    • 2004
  • We researched carbon nanotube(CNT) cartridge as a CNT sample for the fabrication of nanotweezer which is composed of a couple of single CNT tip. Our CNT cartridge was made by dielectrophoretic methods, a kind of micromanipulation technique using electric field. Therein we intended to fabricate the CNT cartridge with just conventional function generators and a set of simple electrode. A knife edge and a flat metal electrode were employed as a couple of electrode, and these electrode pair faced each other with the gap. When the gap is filled with CNT suspension, we induced AC electric field into the gap. Then CNTs was attached on the sharp edge in knife edge by dielectrophoresis. This knife edge with attached CNTs is called as the CNT cartridge.

  • PDF

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

Thermal Conductivity Analysis of Heating Rollers for Cable Low Dust POD Production (저분진 케이블 POD 생산을 위한 히팅 롤러의 열전도 분석)

  • Song, Young-Jun;Lim, Jong-Hak;Byun, Young-il;Hong, Seong-Min;Jeong, Young-Hwan;Park, Jang-Yong;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2022
  • The heating roller of an actual pulse output device (POD) production facility is composed of a steel roller and a rubber roller. The time to reach a specific temperature and the temperature distribution on the roller surface were analyzed and compared according to the change in the number of cartridge heaters inside the heating roller. In this analysis, a steady-state thermal analysis of a steel roller was performed for the cases of a 5-cartridge heater and 9-cartridge heater. Finite element analysis was applied with reference to the surface temperature data of the heating roller during operation and the calorific value of the cartridge heater. Using the 9-cartridge heater, faster target temperature achievement and more uniform temperature distribution were confirmed than for the 5-cartridge heater.

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

Efficiency of Silver Ion-Silica Solid Phase Extraction for Elimination of Sulfur Compounds during Pesticide Multiresidue Analysis in Allium Species (파속류의 잔류농약분석과정에서 silver ion-silica solid phase extraction에 의한 황화합물의 제거 효율성)

  • Park, Jin-Woo;Moon, Kyung-Mi;Choi, Young-Whan;Lee, Young-Guen
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.60-65
    • /
    • 2010
  • Since organic sulfur compounds respond to GC/ECD sensitively, they interfere with quantitative separation of pesticides during residual pesticide analysis of Allium species. In this study, it was intended to develop a rapid and simple method for pesticide multi-residues analysis through clean-up and interferences by a solid-phase extraction (SPE). An SPE method employing silver nitrate impregnated Florosil cartridge was developed and evaluated for the elimination of sulfur compounds from the test solution of Allium species during pesticide residues analysis. The silver nitrate impregnated Florosil cartridge was prepared by efflux of 3 ml of 20% silver nitrate solution through Florosil cartridge (1 g packing, 6 ml tube). The extracts equivalent to 2, 4 6, and 10 g of each sample were loaded onto the cartridge and allowed to exude, and then the exudations were analyzed by GC/ECD. More than 95% of sulfur compounds were removed from the loaded extracts equivalent, up to 6 g in onion, 4 g in spring onion and 4 g in shallot, respectively. 40 pesticides were spiked in the Allium species and loaded onto the cartridge to determine the recoveries; from this, the recoveries of 34 pesticides were within 70~120%.