• Title/Summary/Keyword: Carotid artery plaque

Search Result 33, Processing Time 0.021 seconds

Massive Cerebral Microemboli after Protected Carotid Artery Angioplasty and Stenting Using a Distal Filter Embolic Protection Device for a Vulnerable Plaque with a Lipid Rich Necrotic Core and Intraplaque Hemorrhage: A Case Report (취약한 죽상경화반의 원위 필터형 색전예방장치를 이용한 내경동맥의 스텐트 시술 후 발생한 다량의 뇌 미세혈전: 증례 보고)

  • Hae-Jung Kim;Myung-Ho Rho
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.739-745
    • /
    • 2020
  • A major concern associated with carotid artery angioplasty and stenting (CAS) is a periprocedural distal cerebral embolization. To prevent distal embolization, embolic protection devices (EPDs) have been developed. However, the risk of cerebral embolism after protected CAS in patents with a vulnerable plaque is controversial and either a silent or a symptomatic stroke can occur despite the use of EPDs. Here, we report a case of a massive cerebral microemboli after a protected CAS using a distal filter EPD for a vulnerable plaque with a lipid rich necrotic core and intraplaque hemorrhage.

Modified Suturing Techniques in Carotid Endarterectomy for Reducing the Cerebral Ischemic Time

  • Joo, Sung-Pil;Cho, Yong-Hwan;Lee, Yong-Jun;Kim, You-Sub;Kim, Tae-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.834-840
    • /
    • 2020
  • Objective : Carotid endarterectomy (CEA) is an effective surgical procedure for treating symptomatic or asymptomatic patients with carotid stenosis. Many neurosurgeons use a shunt to reduce perioperative ischemic complications. However, the use of shunting is still controversial, and the shunt procedure can cause several complications. In our institution, we used two types of modified arteriotomy suture techniques instead of using a shunt. Methods : In technique 1, to prevent ischemic complications, we sutured a third of the arteriotomy site from both ends after removing the plaque. Afterward, the unsutured middle third was isolated from the arterial lumen by placing a curved Satinsky clamp. And then, we opened all the clamped carotid arteries before finishing the suture. In technique 2, we sutured the arteriotomy site at the common carotid artery (CCA). We then placed a curved Satinsky clamp crossing from the sutured site to the carotid bifurcation, isolating the unsutured site at the internal carotid artery (ICA). After placing the Satinsky clamp, the CCA and external carotid artery (ECA) were opened to allow blood flow from CCA to ECA. By opening the ECA, ECA collateral flow via ECA-ICA anastomoses could help to reduce cerebral ischemia. Results : The modified suture methods can reduce the cerebral ischemia directly (technique 1) or via using collaterals (technique 2). The modified arteriotomy suture techniques are simple, safe, and applicable to almost all cases of CEA. Conclusion : Two modified arteriotomy suture techniques could reduce perioperative ischemic complications by reducing the cerebral ischemic time.

Carotid Web in Duplex Sonography: 4 Cases (이중초음파에서 관찰된 경동맥갈퀴막: 4례)

  • Han, Minho;Seo, Kangsik;Choi, Junghye
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.78-82
    • /
    • 2020
  • Carotid web is a disease that is rarely found in patients with ischemic stroke, whereas it is more frequently observed in cryptogenic stroke patients. Fibromuscular dysplasia is known as the cause of carotid web, and it has been reported that carotid web causes blood flow disturbance, resulting in both thrombus and embolic stroke. Carotid web is confused with carotid dissection because fibromuscular dysplasia causes relatively rigid fibrous structures to grow into the lumen of the carotid artery and this creates a double lumen that is seen on duplex sonography. In addition, carotid web is web-shaped and may be confused with other carotid artery diseases such as ulcerative plaque. However, carotid web tends to be thicker at the beginning and thinner at the end, and it also has no flutter. Therefore, this study reports on four cases of carotid web with the overall description of the carotid web and the characteristic findings of duplex sonography in patients with carotid web.

Elastic Motion of the Blood Vessel and Wall Shear Stress in Carotid Artery with Stenosis (협착된 경동맥 내의 벽전단응력 및 혈관의 탄성적 거동)

  • Kim Chang Nyung;Oh Taek Yeol;Choi Myung Jin;Jung Sam Doo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.179-187
    • /
    • 2005
  • The characteristics of blood flow and the interaction between the blood vessel and blood flow play important roles in plaque cap rupture and the growth of atherosclerosis which may lead directly to a heart attack or a stroke. In this study, carotid arteries with different stenoses have been numerically simulated to investigate the wall shear stress(WSS) and the elastic motion of the vessel. Blood flow has been treated as physiological, laminar and incompressible flow. To model the shear thining behavior of the blood, the Carreau-Yasuda model has been employed but the viscoelasticity of blood has not been considered. The results show that the WSS of $severe(75\%)$ stenosis is much higher than those of $25\%\;and\;50\%$ stenosis in the region of stenosis. With the increase in the stenosis thickness, the expansion ratio of the center of the stenosis decreases while the expansion ratio of the upstream region of the stenosis increases.

Selective Carotid Shunting Based on Intraoperative Transcranial Doppler Imaging during Carotid Endarterectomy: A Retrospective Single-Center Review

  • Cho, Jun Woo;Jeon, Yun-Ho;Bae, Chi Hoon
    • Journal of Chest Surgery
    • /
    • v.49 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • Background: Carotid endarterectomy (CEA) with selective shunting is the surgical method currently used to treat patients with carotid artery disease. We evaluated the incidence of major postoperative complications in patients who underwent CEA with selective shunting under transcranial Doppler (TCD) at our institution. Methods: The records of 45 patients who underwent CEA with TCD-based selective shunting under general anesthesia from November 2009 to June 2015 were reviewed. The risk factors for postoperative complications were analyzed using univariate and multivariate analysis. Results: Preoperative atrial fibrillation was observed in three patients. Plaque ulceration was detected in 10 patients (22.2%) by preoperative computed tomography imaging. High-level stenosis was observed in 16 patients (35.5%), and 18 patients had contralateral stenosis. Twenty patients (44.4%) required shunt placement due to reduced TCD flow or a poor temporal window. The 30-day mortality rate was 2.2%. No cases of major stroke were observed in the 30 days after surgery, but four cases of minor stroke were noted. Univariate analysis showed that preoperative atrial fibrillation (odds ratio [OR], 40; p=0.018) and ex-smoker status (OR, 17.5; p=0.021) were statistically significant risk factors for a minor stroke in the 30-day postoperative period. Analogously, multivariate analysis also found that atrial fibrillation (p<0.001) and ex-smoker status (p=0.002) were significant risk factors for a minor stroke in the 30-day postoperative period. No variables were identified as risk factors for 30-day major stroke or death. No wound complications were found, although one (2.2%) of the patients suffered from a hypoglossal nerve injury. Conclusion: TCD-based CEA is a safe and reliable method to treat patients with carotid artery disease. Preoperative atrial fibrillation and ex-smoker status were found to increase the postoperative risk of a small embolism leading to a minor neurologic deficit.

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

Flow arrest during carotid artery stenting with a distal embolic protection device: A single-center experience and clinical implications

  • Noah Hong;Jeong-Mee Park;Seung Bin Kim;Young-Je Son
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.163-173
    • /
    • 2024
  • Objective: We aimed to investigate the incidence of flow arrest during carotid artery stenting (CAS) with filter-type embolic protection device (EPD), identify any predisposing factors for those situations, and contemplate intraprocedural precautionary steps. Methods: CAS was performed in 128 patients with 132 arteries using filter-type EPD. The characteristics of treated patients and arteries were compared between groups with and without flow arrest. Results: The incidence of flow arrest during CAS with filter-type EPD was 17.4%. In flow arrest group, cases of vulnerable plaques (p=0.02) and symptomatic lesions (p=0.01) were significantly more common, and there were more cases of debris captured by EPD in a planar pattern (p<0.01). Vulnerable plaques were significantly more common in the procedures showing a planar pattern than in the cases with other patterns (p<0.01). Flow arrest group showed a significantly higher rate of ischemic complications (p<0.05), although there were no significant periprocedural neurological changes. The planar pattern of captured debris in filter-type EPD was the only significant risk factor for flow arrest (adjusted odds ratio 88.44, 95% confidence interval 15.21-514.45, p<0.05). Conclusions: Flow arrest during CAS with filter-type EPD is not uncommon and associated with increased ischemic complications. Symptomatic stenoses and vulnerable plaque are related to this event. The planar pattern of captured debris on the EPD was the only significant risk factor for the flow arrest. Clinicians must pay attention to the occurrence of flow arrest and react quickly when performing CAS.

Impact of Multiple Cardiovascular Risk Factors on the Carotid Intima-media Thickness in Young Adults: The Kangwha Study

  • Chang, Hoo-Sun;Kim, Hyeon-Chang;Ahn, Song-Vogue;Hur, Nam-Wook;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.5
    • /
    • pp.411-417
    • /
    • 2007
  • Objectives: Although risk factors for coronary artery disease are also associated with increased carotid intima-media thickness (IMT), there is little information available on the asymptomatic, young adult population. We examined the association between multiple cardiovascular risk factors and the common carotid IMT in 280 young Korean adults. Methods: The data used for this study was obtained from 280 subjects (130 men and 150 women) aged 25 years who participated in the Kangwha Study follow-up examination in 2005. We measured cardiovascular risk factors, including anthropometries, blood pressure, blood chemistry, carotid ultrasonography, and reviewed questionnaires on health behaviors. Risk factors were defined as values above the sex-specific 75th percentile of systolic blood pressure, body mass index, total cholesterol/ high-density lipoprotein cholesterol ratio, fasting blood glucose and smoking status. Results: The mean carotid IMT${\pm}$standard deviation observed was $0.683{\pm}0.079mm$ in men and $0.678{\pm}0.067mm$ in women (p=0.567) and the evidence of plaque was not observed in any individuals. Mean carotid IMT increased with an increasing number of risk factors(p for trend <0.001) and carotid IMT values were 0.665 mm, 0.674 mm, 0.686 mm, 0.702 mm, and 0.748 mm for 0, 1, 2, 3, and 4 to 5 risk factors, respectively. The odds ratio for having the top quartile carotid IMT in men with 3 or more risk factors versus 0-2 risk factors was 5.09 (95% CI, 2.05-12.64). Conclusions: Current findings indicate the need for prevention and control of cardiovascular risk factors in young adults and more focus on those with multiple cardiovascular risk factors.

Diagnostic Usefulness of High Resolution Cross Sectional MRI in Symptomatic Middle Cerabral Arterial Dissection

  • Lee, Hai-Ong;Kwak, Hyo-Sung;Chung, Gyung-Ho;Hwang, Seung-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.370-372
    • /
    • 2011
  • Dissection of the middle cerebral artery (MCA) is less frequent compared with dissection of the vertebrobasilar system or carotid artery. Recently, high-resolution cross sectional MR imaging (HRMRI) has emerged as a potential technique for atherosclerotic plaque imaging in MCA, We introduce the findings of HRMRI in a 56-year-old woman with traumatic MCA dissection, HRMRI showed an intimal flap and tapered pseudolumen with intra-luminal hemorrhage, We performed stent deployment about MCA dissection after failed medical treatment Three months later, there was no in-stent restenosis and no further neurological deficit were noted.

Correlation between Carotid Intima-media Thickness and Risk Factors for Atherosclerosis (경동맥 내중막 두께에 따른 죽상경화반의 위험요인과의 상관관계)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2019
  • The purpose of this study was to investigate the effect of carotid artery ultrasound Respectively. The carotid intima-media thickness is known to have a significant correlation with cardiovascular disease and cerebrovascular disease. We investigated the relationship between carotid intima - media thickness, body mass index, waist circumference, the blood lipid value, fasting blood glucose, glycated hemoglobin, and blood pressure using carotid artery ultrasound. The carotid artery ultrasound was considered to be abnormality of IMT thickness over 0.8 mm and the presence or absence of atherosclerotic plaque was evaluated. Serological tests were used to compare the geologic value, fasting blood glucose level, and glycated hemoglobin. As a result, waist circumference (=.022), low density cholesterol (=.004), fasting blood glucose level (.019), and glycemic index (.002) were analyzed as predictors of atherosclerosis. In the ROC curve analysis, sensitivity was 87.80% (95% CI: 73.8-95.9), specificity was 41.67% (95% CI: 30.2-53.9), sensitivity was 78.05% (95% CI: 62.4-89.4) in low density lipoprotein, Specificity was 50.00% (95% CI: 38.0-62.0), sensitivity was 73.11% (95% CI: 57.1-85.8), specificity was 61.11 (95% CI: 48.9-72.4) and sensitivity was 82.93%-91.8) and a specificity of 43.06% (31.4-55.3). In logistic regression analysis, the risk of atherosclerosis was 0.248 times at waist circumference (WC)> 76 cm, 3.475 times at low-density lipoprotein (LDL-C) ${\geq}124mg/dL$, 0.618 at HbA1c> 5.4% It appeared as a times. We suggest that prospective study of carotid artery ultrasound should be performed for the effective prevention of cardiovascular diseases.