• Title/Summary/Keyword: Cardiac catheterization

Search Result 200, Processing Time 0.039 seconds

Bronchial Responsiveness in Patients with Mitral Valvular Heart Disease (승모판 심장질환 환자에서 기관지 반응성에 대한 연구)

  • Kim, Ho-Cheol;Kim, Min-Gu;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.752-759
    • /
    • 1995
  • Background: Bronchial asthma is characterized by noctunal dyspnea, cough and wheezing because of airway hyperresponsiveness to nonspecific stimuli. These symptoms and signs are also observed in patients with congestive heart failure. Therefore, this is so called "cardiac asthma". There are lots of experimental and clinical datas to suggest that airway dysfunctions occur in acute and chronic congestive heart failure. However, it is still controversial whether bronchial hyperresponsiveness is present in patients with congestive heart failure. To assess whether bronchial hyperresponsiveness is present in patients with congestive heart failure and to demonstrate the relationship between bronchial responsiveness and vascular pressure, we performed methacholine provocation test in 11 patients with mitral valvular heart disease. Methods: All patients were in the New York Heart Association functional class II and treated continuously with digoxin and/or dichlozid and/or angiotensin converting enzyme inhibitor except one patient. All patients were undergone right and left side heart catheterization for hemodynamic measurements. A 20 percent fall of peak expiratory flow rate were considered as positive response to methacholine provocation test. Results: 1) Only one patient who has normal pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac index was positive in methacholine provocation test. 2) Their mean pulmonary artery pressure, pulmonary capillary wedge pressure were $21.72{\pm}9.70mmHg$, $15.45{\pm}8.69mmHg$ respectively which were significantly higher. Conclusion: It is speculated that in stable congestive heart failure patients, bronchial responsiveness as assessed by methacholine provocation test may not be increased.

  • PDF

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.

Aortic Root Replacement in Patient of Right Ventricular Hypoplasia with Annuloaortic Ectasia, Ventricular Septal Defect and Aortic Regurgitation - Report of 1 case - (대동맥판륜 확장증, 심실중격결손 및 대동맥판막 폐쇄부전과 동반된 우심실 저형성 환자에서 대동맥근부 치환술 -1예 보고)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kang, Sang-Soo;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.510-513
    • /
    • 2003
  • Annuloaortic ectasia, aortic regurgitation(AR), and ventricular septal defect(VSD) in patients with right ventricular hypoplasia is a very rare condition. We report a patient who underwent aortic root replacement with a composite graft for annuloaortic ectasia associated with VSD and AR in right ventricular hypoplasia. The patient was a 19 year-old male. Transthoraic echocardiogram and cardiac catheterization revealed a perimembranous VSD (2 cm in diameter), severe AR, annuloaortic ectasia, bipartite right ventricle with hapoplasia, and hypoplastic tricuspid valve. Operative findings showed that free margins of the right and noncoronary cusps were markedly elongated, thickened, and retracted, and commissure between the right coronary cusp and the noncoronary cusp was fused and calcified. VSD was closed with an autologous pericardial patch and composite graft aortic root replacement using direct coronary button reimplantation was performed, and the hypertrophic muscle of the right ventricular outflow tract was resected. The patient had transient weaning failure of cardiopulmonary bypass and was discharged at the postoperative 14 days without any problems.

Conversion of Total Atrio-pulmonary Connection to Total Cavo-pulmonary Connection - Review of Indications and Hemodynamic Characteristics - (심방-폐동맥 문합술 후 총 체정맥-폐동맥 문합술로의 전환 - 수술 적응증 및 혈역학적 특징의 검토 -)

  • Seo, Jung Ho;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.199-207
    • /
    • 2002
  • Purpose : Since the successful application of total atrio-pulmonary connection(TAPC) to patients with various types of physiologic single ventricles in 1971, post-operative survival rates have reached more than 90%. However some patients have been shown to present with late complications such as right atrial thrombosis, atrial fibrillation and protein losing enteropathy eventually leading to re-operation to control the long-term complications. The aim of this study is to review the results of total cavo-pulmonary connection(TCPC) in cases with late complications after TAPC. Methods : Between Jan. 1995 and Dec. 2000, 6 patients(5 males and 1 female) underwent cardiac catheterization $11{\pm}3$ months after conversion of previous TAPC to TCPC. We compared the hemodynamic and morphologic parameters before and after TCPC and also assessed the clinical outcomes. The indications for TAPC were tricuspid atresia in 4 cases and complex double-outlet right ventricle with single ventricle physiology in 2 cases. Results : There was no peri-operative mortality and all patients were clinically and hemodynamically improved at a mean follow-up of 11 months(range : 4 to 13). However, protein losing enteropathy recurred in 2 patients; this was were successfully treated with subcutaneous administration of heparin. Right atrial pressure before TCPC was $18.0{\pm}3.6mmHg$, but baffle pressure, corresponding to right atrial pressure decreased to $14.8{\pm}3.6mmHg$ after TCPC. The size of the pulmonary arteries did not regress after TCPC. Conclusion : The conversion of TAPC to TCPC improves clinical and hemodynamic status by decreasing the right atrial pressure and by providing a laminar cavo-pulmonary flow which enhances the effective pulmonary circulation in the so-called Fontan circulation.

Aortic Valvuloplasty Using Leaflet Extension Technique (판막첨 연장술을 이용한 대동맥판막 성형술의 중기성적 평가)

  • Ahn, Hyuk;Kim, Hyun-jo
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.656-662
    • /
    • 1997
  • Aortic valvuloplasty has recently gained attention as an attractive alternative procedure for aortic valvular disease. Between March 1995 to August 1996, 14 patients with pure aortic regurgitation(AR) underwent aortic alvuloplasty using leaflet extension with glutaraldehydepreserved autologous pericardium. There were 11 males and 3 females, and the mean age was 34.8 $\pm$ 15.3 years. Preoperative echocardiography and cardiac catheterization revealed that the degree of AR was mean 3.4$\pm$0.65, and more than moderate degree of mitral regurgitation(MR) were detected in 4 patients. In 12 patients, 3 leaflets were extended and in another 2 patients only one deformed leaflet was extended. Concomitant mitral valvuloplasty (MVP) was performed in 4 patients. The competency of the aortic valve after completion of repair was evaluated by the transesophageal echocardiography in operating theater, and there was no aortic and mitral stenosis or regurgitation. In an early postoperative echocardiography, trivial AR was detected in 3 patients and mild MR in 1 patient. The end-systolic and end-diastolic dimensions of the left ventricle were decreased significantly(p<0.05) as compared with those of preoperative values. T ere was no mortality and no significant postoperative complication encountered. Late complication developed in 2 patients during the follow-up period(mean 7.9$\pm$ 5.9 months). One patient underwent AVR on postoperative 7th month due to endocarditis, and the another patient with Behcet's disease underwent Ross operation at postoperative 4th month. In conclusion, AVP of leaflet extension technique offers an excellent early clinical result and represents a good alterna!ivy surgical treatment for the pure AR especially in young age group, although long-term follow-up is necessary to determine the durability of glutaraldehyde-preserved autologous pericardium as a valve leaflet.

  • PDF

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis (Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.861-866
    • /
    • 1998
  • Background: Pulmonary atresia (PA) with ventricular septal defect has various morphology of pulmonary arteries and pulmonary blood flow sources, so pulmonary arterial hypoplasia and arborization abnormality make this anomaly difficult to manage surgically. In cases associated with juxtaductal stenosis, we evaluated the change of the pulmonary arterial and juxtaductal stenotic site after shunt operations, and would like to find useful information in surgical planning and methodology of these patients. Material and Method: Among 59 cases diagnosed as PA with ventricular septal defect associated with juxtaductal stenosis, 29 cases who had cardiac catheterization before and after shunt operation were selected from July, 1991 to July, 1996. In 10 cases of right shunt operation(Group I) and 19 cases of left shunt operation (Group II), the diameters of the descending aorta, both pulmonary arteries, and the juxtaductal stenosis site were measured before and after the shunt operation. Result: In both Group I and II, the pre- and postoperative ratio of diameters of the ipsilateral pulmonary artery to the descending aorta was from 0.78${\pm}$0.31 units to 1.01${\pm}$0.26 units and from 0.67${\pm}$0.18 units to 0.84${\pm}$0.27 units respectively, showing a signigicant increase. The contralateral pulmonary artery index was increased from 0.92${\pm}$0.28 units to 1.05${\pm}$0.15 units and from 0.94${\pm}$0.27 units to 1.08${\pm}$0.37 units respectively, but could not be confirmed statistically. In both groups, the change of juxtaductal stenosis showed an aggravating tendency but of no statistical significance from 0.43${\pm}$0.27 units to 0.39${\pm}$0.25 units and from 0.32${\pm}$0.10 units to 0.30${\pm}$0.16 units respectively, and we experienced 2 total obstruction in Group II. Because the increased pulmonary blood flow by shunt operation has a favorable effect to the pulmonary arterial growth, the shunt operation is a recommended treatment in patients with hypoplastic pulmonary arteries. But in PA with ventricular septal defects, the change of juxtaductal stenosis is very important. In conclusion, the growth of ipsilateral (shunt site) pulmonary artery was promoted by shunt operation, but there is a tendency for the juxtaductal stenosis to be aggravated. And we experienced 2 total obstruction in Group II. Conclusion: Thus, in cases operated with shunt method, much careful postoperative follow up study including angiographic evaluation is needed, and after the shunt operation on the side of pulmonary artery associated with juxtaductal stenosis, early precise planning for total correction is recommended.

  • PDF

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

The Clinical Application and Results of Palliative Damus-Kaye-Stansel Procedure (고식적 Damus-Kaye-Stansel 술식의 임상적 적용 및 결과)

  • Lim, Hong-Gook;Kim, Soo-Jin;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul;Shinn, Sung-Ho;Yie, Kil-Soo;Lee, Jae-Woong;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Background: The Damus-Kaye-Stansel (DKS) procedure is a proximal MPA-ascending aorta anastomosis used to relieve systemic ventricular outflow tract obstructions (SVOTO) and pulmonary hypertension. The purpose of this study was to review the indications and outcomes of the DKS procedure, including the DKS pathway and semilunar valve function. Material and Method: A retrospective review of 28 patients who underwent a DKS procedure between May 1994 and April 2006 was performed. The median age at operation was 5.3 months ($13\;days{\sim}38.1\;months$) and body weight was 5.0 kg ($2.9{\sim}13.5\;kg$). Preoperative pressure gradients were $25.3{\pm}15.7\;mmHg$ ($10{\sim}60\;mmHg$). Eighteen patients underwent a preliminary pulmonary artery banding as an initial palliation. Preoperative main diagnoses were double outlet right ventricle in 9 patients, double inlet left ventricle with ventriculoarterial discordance in 6,. another functional univentricular heart in 5, Criss-cross heart in 4, complete atrioventricular septal defect in 3, and hypoplastic left heart variant in 1. DKS techniques included end-to-side anastomosis with patch augmentation in 14 patients, classical end-to-side anastomosis in 6, Lamberti method (double-barrel) in 3, and others in 5. The bidirectional cavopulmonary shunt and Fontan procedure were concomitantly performed in 6 and 2 patients, respectively. Result: There were 4 hospital deaths (14.3%), and 3 late deaths (12.5%) with a follow-up duration of $62.7{\pm}38.9$ months ($3.3{\sim}128.1$ months). Kaplan-Meier estimated actuarial survival was $71.9%{\pm}9.3%$ at 10 years. Multivariate analysis showed right ventricle type single ventricle (hazard ratio=13.960, p=0.004) and the DKS procedure as initial operation (hazard ratio=6.767, p=0.042) as significant mortality risk factors. Four patients underwent staged biventricular repair and 13 received Fontan completion. No SVOTO was detected after the procedure by either cardiac catheterization or echocardiography except in one patient. There was no semiulnar valve regurgitation (>Gr II) or semilunar valve-related reoperation, but one patient (3.6%) who underwent classical end-to-side anastomosis needed reoperation for pulmonary artery stenosis caused by compression of the enlarged DKS pathway. The freedom from reoperation for the DKS pathway and semilunar valve was 87.5% at 10 years after operation. Conclusion: The DKS procedure can improve the management of SVOTO, and facilitate the selected patients who are high risk for biventricular repair just after birth to undergo successful staged biventricular repair. Preliminary pulmonary artery banding is a safe and effective procedure that improves the likelihood of successful DKS by decreasing pulmonary vascular resistance. The long-term outcome of the DKS procedure for semilunar valve function, DKS pathway, and relief of SVOTO is satisfactory.