• Title/Summary/Keyword: Cardiac catheter

Search Result 81, Processing Time 0.024 seconds

Development and physiological assessments of multimedia avian esophageal catheter system

  • Nakada, Kaoru;Hata, Jun-ichi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.121-130
    • /
    • 2018
  • We developed multimedia esophageal catheters for use with birds to measure and record ECG and angular velocity while anesthesized, at rest, and in flight. These catheters enable estimates of blood pressure based on readings given by an angular velocity sensor and by RR intervals of ECG affected by EMG. In our experiments, the catheters had the following characteristics: 1. Esophageal catheters offer a topological advantage with 8-dB SNR improvement due to elimination of electromyography (EMG). 2. We observed a very strong correlation between blood pressure and the angular velocity of esophageal catheter axial rotation. 3. The impulse conduction pathway (Purkinje fibers) of the cardiac ventricle has a direction opposite to that of the mammalian pathway. 4. Sympathetic nerves predominate in flight, and RR interval variations are strongly suppressed. The electrophysiological data obtained by this study provided especially the state of the avian autonomic nervous system activity, so we can suspect individual's health condition. If the change of the RR interval was small, we can perform an isolation or screening from the group that prevent the pandemics of avian influenza. This catheter shall be useful to analysis an avian autonomic system, to perform a screening, and to make a positive policy against the massive infected avian influenza.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

Recent advances in pediatric interventional cardiology

  • Kim, Seong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.8
    • /
    • pp.237-244
    • /
    • 2017
  • During the last 10 years, there have been major technological achievements in pediatric interventional cardiology. In addition, there have been several advances in cardiac imaging, especially in 3-dimensional imaging of echocardiography, computed tomography, magnetic resonance imaging, and cineangiography. Therefore, more types of congenital heart diseases can be treated in the cardiac catheter laboratory today than ever before. Furthermore, lesions previously considered resistant to interventional therapies can now be managed with high success rates. The hybrid approach has enabled the overcoming of limitations inherent to percutaneous access, expanding the application of endovascular therapies as adjunct to surgical interventions to improve patient outcomes and minimize invasiveness. Percutaneous pulmonary valve implantation has become a successful alternative therapy. However, most of the current recommendations about pediatric cardiac interventions (including class I recommendations) refer to off-label use of devices, because it is difficult to study the safety and efficacy of catheterization and transcatheter therapy in pediatric cardiac patients. This difficulty arises from the challenge of identifying a control population and the relatively small number of pediatric patients with congenital heart disease. Nevertheless, the pediatric interventional cardiology community has continued to develop less invasive solutions for congenital heart defects to minimize the need for open heart surgery and optimize overall outcomes. In this review, various interventional procedures in patients with congenital heart disease are explored.

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

Practical stepwise approach to rhythm disturbances in congenital heart diseases

  • Huh, June
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.6
    • /
    • pp.680-687
    • /
    • 2010
  • Patients with congenital heart diseases (CHD) are confronted with early- and late-onset complications, such as conduction disorders, arrhythmias, myocardial dysfunction, altered coronary flow, and ischemia, throughout their lifetime despite successful hemodynamic and/or anatomical correction. Rhythm disturbance is a well-known and increasingly frequent cause of morbidity and mortality in patients with CHD. Predisposing factors to rhythm disturbances include underlying cardiac defects, hemodynamic changes as part of the natural history, surgical repair and related scarring, and residual hemodynamic abnormalities. Acquired factors such as aging, hypertension, diabetes, obesity, and others may also contribute to arrhythmogenesis in CHD. The first step in evaluating arrhythmias in CHD is to understand the complex anatomy and to find predisposing factors and hemodynamic abnormalities. A practical stepwise approach can lead to diagnosis and prompt appropriate interventions. Electrophysiological assessment and management should be done with integrated care of the underlying heart defects and hemodynamic abnormalities. Catheter ablation and arrhythmia surgery have been increasingly applied, showing increasing success rates with technological advancement despite complicated arrhythmia circuits in complex anatomy and the difficulty of access. Correction of residual hemodynamic abnormalities may be critical in the treatment of arrhythmia in patients with CHD.

Bilateral Cardiac Sympathetic Denervation as a Safe Therapeutic Option for Ventricular Arrhythmias

  • Soo Jung Park;Deok Heon Lee;Youngok Lee;Hanna Jung;Yongkeun Cho
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.414-419
    • /
    • 2023
  • Background: The recurrence of ventricular arrhythmias (VAs) in patients who have already undergone treatment with antiarrhythmic medication, catheter ablation, and the insertion of implantable cardioverter defibrillators is not uncommon. Recent studies have shown that bilateral cardiac sympathetic denervation (BCSD) effectively treats VAs. However, only a limited number of studies have confirmed the safety of BCSD as a viable therapeutic option for VAs. Methods: This single-center study included 10 patients, who had a median age of 54 years (interquartile range [IQR], 45-65 years) and a median ejection fraction of 58.5% (IQR, 56.2%-60.8%), with VAs who underwent video-assisted BCSD. BCSD was executed as a single-stage surgery for 8 patients, while the remaining 2 patients initially underwent left cardiac sympathetic denervation followed by right cardiac sympathetic denervation. We evaluated postoperative complications, the duration of hospital stays, and VA-related symptoms before and after surgery. Results: The median hospital stay after surgery was 2 days (IQR, 2-3 days). The median surgical time for BCSD was 113 minutes (IQR, 104-126 minutes). No significant complications occurred during hospitalization or after discharge. During the median follow-up period of 13.5 months (IQR, 10.5-28.0 months) from surgery, no VA-related symptoms were observed in 70% of patients. Conclusion: The benefits of a short postoperative hospitalization and negligible complications make BCSD a safe, alternative therapeutic option for patients suffering from refractory VAs.

Surgical Removal of a IVUS Catheter that was Fractured During PCI (경피적 관상동맥 중재술 시 골절된 혈관 내 IVUS 카테터의 외과적 제거)

  • Kim, Young-Hak;Kim, Hyuck;Song, Young-Joo;Chung, Won-Sang;Kang, Jeong-Ho
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.768-771
    • /
    • 2008
  • The use of IVUS provides information about the lumen and arterial wall, the location and extent of atherosclerotic plaque and the state of the arterial wall after PCi. The use of IVUS after insertion of an intracoronary stent has currently increased, while conflicting evidence exists concerning the long-term benefits of IVUS. We report here on a case of surgical removal of an entrapped and fractured IVUS catheter during insertion of intracoronary stents, and we include a review of the relevant literature.

Manual Aspiration Thrombectomy Using Penumbra Catheter in Patients with Acute M2 Occlusion : A Single-Center Analysis

  • Park, Jung Soo;Kwak, Hyo Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.352-356
    • /
    • 2016
  • Objective : The efficacy and safety of manual aspiration thrombectomy using Penumbra in an acute occlusion of large intracranial arteries has been proven in many previous studies. Our study aimed to retrospectively assess the efficacy and safety of manual aspiration thrombectomy using Penumbra in patients with small vessel occlusions (M2 segment of the MCA). Methods : We conducted a retrospective review of 32 patients who underwent manual aspiration thrombectomy using the Penumbra 4 MAX Reperfusion Catheter for treatment of an M2 occlusion between January 2013 and November 2014. We evaluated immediate angiographic results and clinical outcomes through review of patient electronic medical records. Results : There were slightly more men in this study (M : F=18 : 14) and the median age was 72.5 (age range : 41-90). The rate of successful recanalization (TICI grade ${\geq}2b$) was 84% (27/32). NIHSS at discharge and favorable clinical outcomes at 3 months were significantly improved than baseline. Median initial NIHSS score was 10 (range : 4-25) and was 4 (range : 0-14) at discharge. Favorable clinical outcomes (mRS score ${\leq}2$ at 3 months) were seen in 25 out of 32 patients (78%). There were no procedure-related symptomatic intracerebral hemorrhages. One patient expired after discharge due to a cardiac problem. Conclusion : Manual aspiration thrombectomy might be safe and is capable of achieving a high rate of successful recanalization and favorable clinical outcomes in patients with distal cerebral vessel occlusion (M2).

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Pain alleviation in patients undergoing cardiac surgery; presternal local anesthetic and magnesium infiltration versus conventional intravenous analgesia: a randomized double-blind study

  • Kamel, Emad Zarief;Abd-Elshafy, Sayed Kaoud;Sayed, Jehan Ahmed;Mostafa, Mohammed Mahmoud;Seddik, Mohamed Ismail
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.93-101
    • /
    • 2018
  • Background: Magnesium is one of the effective, safe local anesthetic adjuvants that can exert an analgesic effect in conditions presenting acute and chronic post-sternotomy pain. We studied the efficacy of continuous infusion of presternal magnesium sulfate with bupivacaine for pain relief following cardiac surgery. Methods: Ninety adult patients undergoing valve replacement cardiac surgery randomly allocated into three groups. In all patients; a presternal catheter was placed for continuous infusion of either 0.125% bupivacaine and 5% magnesium sulfate (3 ml/h for 48 hours) in group 1, or 0.125% bupivacaine only in the same rate in group 2, versus conventional intravenous paracetamol and ketorolac in group 3. Rescue analgesia was iv $25{\mu}g$ fentanyl. Postoperative Visual Analog Scale (VAS) and fentanyl consumption during the early two postoperative days were assessed. All patients were followed up over two months for occurrence of chronic post-sternotomy pain. Results: VAS values showed high significant differences during the first 48 hours with the least pain scale in group 1 and significantly least fentanyl consumption ($30.8{\pm}7{\mu}g$ in group 1 vs. $69{\pm}18{\mu}g$ in group 2, and $162{\pm}3$ in group 3 respectively). The incidence of chronic pain has not differed between the three groups although it was more pronounced in group 3. Conclusions: Continuous presternal bupivacaine and magnesium infusion resulted in better postoperative analgesia than both presternal bupivacaine alone or conventional analgesic groups.