• Title/Summary/Keyword: Cardiac PET

검색결과 28건 처리시간 0.033초

핵의학 영상을 이용한 생존심근 평가 (Assessment of Viable Myocardium with Nuclear Imaging)

  • 강원준
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권3호
    • /
    • pp.203-206
    • /
    • 2009
  • Nuclear cardiac imaging has been widely used to assess viable myocardium in patients with ischemic heart disease, The assessment of viable myocardium is important in selecting patients who will be benefit from revascularization. Although revascularization is indicated in patients with sufficient myocardium, patients with scar tissue should be treated medically. Nuclear imaging methods including myocardial perfusion SPECT and FDG PET have been shown to be effective modalities for identifying viable myocardium.

F-18 fluorodeoxyglucose positron emission tomography/computed tomography in the infection of heart

  • Kong, Eunjung
    • Journal of Yeungnam Medical Science
    • /
    • 제38권2호
    • /
    • pp.95-106
    • /
    • 2021
  • Infections involving the heart are becoming increasingly common, and a timely diagnosis of utmost importance, despite its challenges. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is a recently introduced diagnostic tool in cardiology. This review focuses on the current evidence for the use of FDG PET/CT in the diagnosis of infective endocarditis, cardiac implantable device infection, left ventricular assist device infection, and secondary complications. The author discusses considerations when using FDG PET/CT in routine clinical practice, patient preparation for reducing physiologic myocardial uptake, acquisition of images, and interpretation of PET/CT findings. This review also functions to highlight the need for a standardized acquisition protocol.

파어탕의 L-NAME 유도 고혈압 동물군에서의 혈압강하효과 및 심신기능 개선 효과 (Beneficial effects of Paeo-tang on cardiovascular and renal function in L-NAME-induced hypertensive rats)

  • 나세원;홍미현;김혜윰;장윤재;윤정주;이윤정;강대길;이호섭
    • 대한한의학방제학회지
    • /
    • 제28권3호
    • /
    • pp.271-280
    • /
    • 2020
  • Hypertension has been approved to cause disharmony between the heart and kidney such as cardiac hypertrophy and kidney dysfunction. In traditional oriental medicine Paeo-tang (PET) has been shown to have effects on blood circulation improvement. However, the beneficial effect of PET on hypertension remains unknown. In this study, we investigated that PET attenuates blood pressure and improves cardiovascular and renal function in NG-nitro-L-arginine methylester (L-NAME) rat model. Hypertensive rat models were induced by the administration of L-NAME (40 mg/kg/day) and then PET (50 or 100 mg/kg/day) or Olmetec was treated for 2 weeks. PET treatment significantly suppressed the systolic blood pressure and decreased intima-media thickness in the thoracic aorta. PET ameliorated endothelium-dependent and independent vascular relaxation in the L-NAME-induced vascular dysfunction. PET ameliorated the functional decline in the kidney such as albumin and blood urea nitrogen in plasma. These results demonstrated that PET possesses protective effects against L-NAME-induced hypertension.

$^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계 (Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET)

  • 이병일;김계훈;김정영;김수진;이재성;민정준;송호천;범희승
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.194-200
    • /
    • 2007
  • 목적: $^{13}N$-암모니아는 심근혈류 측정에 유용한 방사성의 약품으로 최근 국내에 도입된 PET/CT를 이용하여 비침습적으로 정량적인 검사를 시행 할 수 있다. 이 연구에서는 $^{13}N$-암모니아를 이용한 동적 영상으로부터 얻은 심근혈류정보와 정적 영상으로부터 얻은 심근관류정보의 상관관계를 살펴봄으로써 심장핵의학 검사의 유용성을 알아보고자 하였다. 방법: 심혈관질환이 의심되어 핵의학 심근관류 검사를 시행한 12명(남 11명, 여 1명, 평균나이 $57.9{\pm}8.6$세)을 대상으로 $^{13}N$-암모니아 검사를 시행하였다. 휴식기와 부하기에서 영상획득을 위하여 $^{13}N$ 암모니아 0.3 mCi/kg를 15초간 순간주사하면서 동시에 동적영상을 6분간(5초씩 12회, 10초씩 6회, 20초씩 3회, 30초씩 6회) 획득하고 이어서 게이트 영상을 13분간 각각 획득하였다. 심근혈류의 측정은 기저부 4분절, 중간부 4분절, 그리고 심첨부로 구성된 9분절 모델을 이용하였으며, 추출한 시간-방사능곡선과 추적자 모델을 사용하여 정량화 하였다. 심근관류는 정량화 분석 소프트웨어를 사용하여 구하였다. 20분절 모델을 9분절 모델과 비교하기 위하여 최기저부 6분절은 제외하고 인접분절의 값을 평균하여 사용하였다. 결과: 심근혈류량(휴식기, 0.18-2.38 ml/min/g; 부하기, 0.4-4.95 ml/min/g)과 심근섭취율(휴식기, 22-91%; 부하기, 14-90%) 간에는 약한 상관관계가 있었으며, 휴식기 보정된 심근관류와 혈류의 상관이 부하기에서보다 더 컸다(휴식기 r=0.59, 부하기 r=0.80). 수축기 심근두꺼워짐이 좋을수록 보정된 관상동맥 혈류예비능과 심근관류 예비능이 상관관계를 보였다. 결론: $^{13}N$-암모니아를 이용한 관류값을 특성에 따라 보정하고 해석하였을 때, 동적영상에서 절대값으로 구한 심근혈류와 좋은 상관관계를 보였다. 따라서 심근관류가 심근혈류를 잘 반영하는 지표임을 보였으므로 심장질환에서의 PET-CT 검사를 유용하게 활용할 수 있을 것으로 기대한다.

양전자단층촬영에 이용 가능한 새로운 심근 혈류 추적자 개발; F-18이 표지된 유기암모늄염의 합성과 체내분포에 관한 연구 (Synthesis and $^{18}F$ Labelling of Organic Ammonium Salts to New Cardiac Flow Tracer for PET and Their Biodistribution)

  • 유국현
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.331-337
    • /
    • 1994
  • In order to develop a $^{18}F$-labelled myocardial perfusion agent(flow tracer) for PET, $^{18}F$-labelled organic ammonium cations were synthesized and evaluated in relation to their biodistribution. Five quaternary organic ammonium compounds were labelled with $^{18}F$ in a side chain with moderate to good yields by direct introduction of $^{18}F$-fluoride. Radiochemical yields have been achieved in 30-40min by the precursors (tosylates) in dimethylsulfoxide 15-60% (decay corrected). The reaction was found to be autocatalyzed. A remote controlled procedure was developed in these synthesis. $^{18}F$-Labelling and HPLC-purification of com-pounds needed about 60 min(Yield; 7-20%). Up to now the two compounds N-4-[$^{18}F$]fluorobutyl-pyridinium cation(1) and N, N dibenzyl-4(2-[$^{18}F$]fluoroethyl)piperidinium cation(2) were investigated in relation to their biodistribution in mice. Compound 1 showed at 1 min post injection the high uptake of 19.22% ID/g organ in the myocardium but a following fast decline to 1.12% ID/g organ after 40min. Uptake of compound 2 was after 1min in the heart 5.90% ID/g organ but after 40min at the relative high value of 4.33% ID/g organ. Heart:blood ratio for compound(1) at 1 min was 8.3, at 40 min 2.6 for compound II 2.0(1min) and 15.0(40 min). As data of compound 2 showed greater heart uptake, slower myocardial release, and higher heart: blood ratios, compound 2 is a good candidate for further evaluation.

  • PDF

좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 TI-201 재분포 SPECT와 휴식기 N-13 Ammonia PET: 분절 비교 및 불일치 분석 (TI-201 Redistribution SPECT and N-13 Ammonia PET Images in Patients with Old Myocardial Infarction and Left Ventricular Dysfunction: Segmental Comparison and Discordance Analysis)

  • 최준영;이경한;김영환;이은정;정현우;이수진;이상훈;김병태
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.218-224
    • /
    • 2004
  • 목적: 이 연구에서는 좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 생존 가능한 심근을 평가하기 위하여 시행한 휴식기 N-13 ammonia PET과 TI-201 재분포 SPECT를 분절단위로 비교해 보고, PET/SPECT 불일치를 일으키는 기전을 알아 보았다. 대상 및 방법 : 심근경색 병력과 좌심실기능이상, 그리고 약물 부하-휴식 TI-201 SPECT 상 1분절 이상의 고정관류결손이 있는 18명(남 17, 여 1; 나이 $59.7{\pm}8.9$세)을 대상으로 N-13 ammonia/F-18 FDG 심근 PET을 시행하였다. 좌심실을 5분절로 나누어 분절별로 혈류와 대사를 육안 및 정량분석으로 평가하였다. 결과: 재분포 TI-201 SPECT와 N-13 ammonia PET은 전체 90분절 중 80분절에서 일치하는 섭취양상을 보여 88.9%의 높은 일치율과 정량분석상의 높은 상관관계 (R=0.81, p<0.001)를 보였다. 전체 환자 중 9명에서는 재분포 TI-201 SPECT와 N-13 ammonia PET이 모든 분절에서 일치하였으며(환자군 1), 나머지 9명의 10분절(하벽 9, 심첨부 1)에서는 TI-201 SPECT상 관류결손을 보이면서 N-13 ammonia PET상 섭취가 거의 정상을 보였다(환자군 2). 환자군 1과 2사이에 좌심실수혈율의 유의한 차이는 없었지만, 환자군 2에서 수축기 및 이완기 좌심실내경이 환자군 1보다 유의하게 커져있었다. 환자군2에서 감쇠보정이 안 된 N-13 ammonia PET 영상을 재구성해서 TI-201 재분포 SPECT 영상과 비교하였을 때, 두 영상 모두 하벽에 비슷한 양상의 관류결손이 발견되었다. 결론: 좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 생존 가능한 심근을 찾기 위한 혈류/대사 PET에서 TI-201 재분포 SPECT와 N-13 ammonia PET은 높은 판독 일치율과 높은 상관관계를 보인다. PET/SPECT 불일치 소견은 주로 좌심실 확장이 심한 환자에서의 거의 정상인 관류 PET을 보이면서 TI-201 SPECT 상 하벽의 고정 관류 결손이며, 이의 기전은 확장된 심실 내부의 혈액과 횡격막에 의한 감쇠로 생각된다.

원발성 악성 심막 중피종 1예 (A Case of Primary Pericardial Malignant Mesothelioma)

  • 김도연;김영균;김영;장윤수;김형중;안철민;유영훈
    • Tuberculosis and Respiratory Diseases
    • /
    • 제57권6호
    • /
    • pp.599-603
    • /
    • 2004
  • 원발성 악성 심막 중피종은 예후가 극히 불량하며 심막에 생기는 중배엽성 기원의 매우 드문 종양으로 주로는 심막염, 심낭 삼출액의 증상으로 나타나며 심낭 개창술 및 심낭 삼출액 세포진 검사에도 종양세포를 증명하기가 어렵고 이런 경우 심장 초음파와 흉부 전산화 단층 촬영만으로 심낭삼출액 및 심막염의 진단외에 양성 심막염과 악성 심막질환의 감별 진단이 어렵다. 최근 전신 양전자 방출 단층촬영(FDG-PET)이 양성과 악성 질환을 감별하는데 널리 이용되고 있으며 이는 원발성 악성 심막 종양의 감별 진단에도 유용하게 사용될 수 있다. 저자들은 호흡곤란과 흉통을 증상으로 내원한 55세 여자 환자에서 전신 양전자 방출 단층촬영(FDG-PET)을 이용하여 심막에 국한된 FDG 고흡착 소견의 원발성 심막 종양을 진단하고 조직검사상 원발성 악성 심막 중피종으로 진단하고 치료한 1례를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화 (Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis)

  • 최용;김준영;임기천;김종호;우상근;이경한;김상은;최연성;김병태
    • 대한핵의학회지
    • /
    • 제33권3호
    • /
    • pp.316-326
    • /
    • 1999
  • 목적: N-13 암모니아 PET 동적영상에 포함된 순수 한 혈액풀 입력함수와 심근 조직함수를 추출하며 각 조직 인자영상을 생성하는 인자분석 방법을 개발하고자 하였다. 또한 인자분석 방법으로 추출된 입력함수와 조직함수를 사용하여 혈류량을 측정하여 구현한 인자분석 방법의 정확도와 유용성을 고찰하였다. 대상 및 방법: 다섯 명의 관상동맥질환 환자에 20 mCi N-13 암모니아를 안정상태와 부하상태에서 주사한 후, 23분간 26프레임의 PET 동적영상을 얻었다. 인자분석을 수행하기 위해 첫째, N-13 암모니아 PET 동적영상을 3차원 행렬화 한 후, 부분영상을 추출하여 딕셀을 생성, 규격화하였다. 두 번째 주 대각성분분석 단계에서는 공분산행렬을 계산하여 인자부하량을 구하며, 세 번째 단계에서는 인자부하량이 양의 구속조건을 만족할 때까지 인자함수를 사갈 회전시켰다. 네 번째 단계에서는 인자영상과 시간-방사능 곡선을 추출하였다. 인자분석 방법의 효율성과 정확성을 검증하고자 인자분석과 관심영역설정 방법으로 구한 혈액풀 입력함수의 곡선 아래 면적을 비교하고, 두 가지 방법으로 구한 입력함수와 조직함수를 이용하여 심근 혈류량을 측정하여 선형 회귀분석하였다. 결과: 관심영역 설정 방법과 개발된 인자분석 방법을 이용하여 구한 혈액풀 입력함수의 $0{\sim}1$분 사이의 평균 곡선 아래 면적 비는 1.02, $0{\sim}2$분 사이는 0.98, $1{\sim}2$분 사이는 0.86이었다. 또한 인자분석과 관심영역 설정 방법으로 얻은 입력함수와 관심영역 설정 방법으로 얻은 조직함수로 구한 심근 혈류량의 선형 회귀곡선 기울기는 0.91, 상관계수는 0.82로 서로 잘 일치하였다. 결론: N-13 암모니아 PET 동적영상을 인자분석 하는 방법을 구현하여 각 조직 인자영상과 이에 대응하는 시간-방사능 곡선을 추출하였으며, 인자분석과 관심영역 설정 방법으로 얻은 혈액풀 입력함수가 서로 잘 일치됨을 검증하였다. 또한, 인자분석 방법과 관심영역 설정방법으로 얻은 시간-방사능 곡선으로 구한 심근 혈류량 값들이 서로 좋은 상관관계를 나타내는 것으로 관찰되어 인자분석 방법으로 추출된 혈액풀 입력함수와 심근 조직함수가 순수한 생리적 함수들과 잘 일치된다고 판단할 수 있었다. 그러므로 N-13 암모니아 PET과 인자분석 방법을 이용하면 혈액 채취, 관심영역 설정, 흘러넘침 보정없이 심근 혈류량을 비침습적으로 간단하고 정확하게 정량화 할 수 있다.

  • PDF

18F-Sodium fluoride PET 이용한 심장 석회화 정량평가에 대한 고찰 (The Quantitative Evaluation of Cardiac Calcification Using 18F-Sodium fluoride PET/CT)

  • 최용훈;이승재;강천구;임한상;김재삼
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.38-42
    • /
    • 2019
  • 관상동맥 석회화 검사에 컴퓨터단층촬영(Comtuted tomography, CT)을 사용하지만 고위험군인 미세석회화 감별에는 어려움이 있다. $^{18}F$-sodium fluoride ($^{18}F-NaF$)가 미세석회화를 진단하는데 매우 유용하다는 연구가 해외에서 보고되고 있다. 본 논문에서는 $^{18}F-NaF$ PET 영상으로 석회화를 정량평가 하고 그 유용성을 알아보고자 한다. 환자는 총 45명($67.1{\pm}6.9$세)으로 $^{18}F-NaF$을 250 MBq 주입하고 1시간 뒤 30분간 영상을 획득하였다. 장비는 Discovery 710 (GE Healthcare, MI, USA)을 사용하였으며 모든 환자는 PET 검사 전 혈관조영CT (CTAngiography, CTA)를 촬영 하였다. 석회화의 SUVmax를 측정하고 좌심방의 배후방사능을 측정하여 Target to Background (TBR) 구한 뒤 정량 분석하였다. ROC 곡선(Receiver Operating Characteristic Curve)을 통하여 고위험군을 분류하였다. 융합영상에서 관상동맥 석회화는 226개로 나왔으며 SUVmax는 $1.15{\pm}0.39$으로 나왔다. 28명(62%)에서 58개가 고위험군으로(TBR>1.25)분류 되었다. 나머지 168개는 $TBR{\leq}1.25$로 나왔다. $^{18}F-NaF$ PET 영상으로 미세석회화의 정량평가가 가능하였고 고위험군을 분류할 수 있었다. 혈관조영CT와 $^{18}F-NaF$ PET을 병행한다면 위험도가 높은 미세석회화를 조기 진단하는 새로운 영상 진단법이 될 수 있을 것으로 사료된다.