• 제목/요약/키워드: Cardiac MRI

검색결과 105건 처리시간 0.023초

Screening in the Era of Economic Crisis: Misperceptions and Misuse from a Longitudinal Study on Greek Women Undergoing Benign Vacuum-assisted Breast Biopsy

  • Domeyer, Philip John;Sergentanis, Theodoros Nikolaos;Katsari, Vasiliki;Souliotis, Kyriakos;Mariolis, Anargiros;Zagouri, Flora;Zografos, George Constantine
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5023-5029
    • /
    • 2013
  • Background: To evaluate knowledge about screening tests and tests without proven screening value in a Greek Breast Unit population undergoing benign vacuum-assisted breast biopsy (VABB). Materials and Methods: This study included 81 patients. Three knowledge-oriented items (recommended or not, screening frequency, age of onset) were assessed. Regarding screening tests two levels of knowledge were evaluated: i). crude knowledge (CK), i.e. knowledge that the test is recommended and ii). advanced knowledge (AK), i.e. correct response to all three knowledge-oriented items. Solely CK was evaluated for tests without proven screening value. Risk factors for lack of knowledge were assessed with multivariate logistic regression. A second questionnaire was administered 18 months after VABB to assess its impact on the performance of tests. Results: Concerning screening tests considerable lack of AK was noted (mammogram, 60.5%; Pap smear, 59.3%; fecal occult blood testing, 93.8%; sigmoidoscopy, 95.1%). Similarly lack of CK was documented regarding tests without proven screening value (breast self-examination, 92.6%; breast MRI, 60.5%; abdominal ultrasound, 71.6%; barium meal, 48.1%; urine analysis, 90.1%; chest X-Ray, 69.1%; electrocardiogram, 74.1%; cardiac ultrasound, 75.3%). Risk factors for lack of AK were: place of residence (mammogram), age (Pap smear), personal income (sigmoidoscopy); risk factors for lack of CK included number of offspring (breast MRI, chest X-Ray), BMI (abdominal ultrasound), marital status (urine analysis), current smoking status (electrocardiogram). VABB's only effect was improvement in mammogram rates. Conclusions: A considerable lack of knowledge concerning screening tests and misperceptions regarding those without proven value was documented.

민간종합검진 유소견자들의 치료기관 선택에 미치는 영향 (The Influence on Selecting the Medical Institute for Treatment by Patients Who Had Abnormal Findings through the Private Health Screening)

  • 정은주;황병덕
    • 보건의료산업학회지
    • /
    • 제5권4호
    • /
    • pp.1-13
    • /
    • 2011
  • The purpose of this study is to analyze the medical care utilization behavior of patients to whom treatment (surgery) is recommended after they are diagnosed with abnormal findings on health screening and factors affecting the selection of the medical institute for treatment. The data was collected from 291 patients who need treatment or surgery, according to the abnormal findings on the additional examination such as cardiac CT, brain MRI, Gastroscopy and Colonoscopy since four diseases are suspected among of 2,752 people who receive health screening. The results are as follows. First, the most common disease of patients who have abnormal findings by the diagnosis through the results of first testing is colon disease based on through the additional examination. The most common disease of patients who will get treatment (surgery) based on final diagnosis by a doctor who determines the result of health screening on the basis of diagnosis from the first testing is cardiovascular disease. Second, in terms of diseases, patients with cardiovascular disease select the medical institute where they get the health screenings as a place for treatment. Patients with cerebrovascular disease select another medical institute for treatment. Finally, the affective factors of selectivity treatment facility on health screening satisfaction were human, facility, health screening and revisit factors.

패혈증과 신부전에서 회복된 환자에서 급속하게 발생한 미만성 심근 석회화: 증례 보고 (Rapid Development of Diffuse Myocardial Calcification in a Patient after Recovery from Sepsis and Renal Failure: A Case Report)

  • 강미현;김성수;선병주;박재형
    • 대한영상의학회지
    • /
    • 제83권5호
    • /
    • pp.1104-1108
    • /
    • 2022
  • 심근 석회화는 다양한 원인으로 인해서 발생할 수 있다. 하지만 패혈증과 신부전으로 인해서 발생하는 경우는 흔하지 않다. 저자들은 컴퓨터단층촬영과 자기공명영상에서 패혈증과 신부전을 회복한 환자에서 급속하게 좌심실벽에 미만성 석회화를 보이는 증례를 보고하고자 한다.

고주파 차폐용 Mesh를 이용한 자기공명영상 분석 (Magnetic Resonance Image Analysis using MESH for High-frequency Shielding)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.975-982
    • /
    • 2021
  • 본 연구는 체내의 식도용 스텐트와 일플란트에 많이 사용되는 티타늄 성분의 금속성 물질을 사용하여 구리와 black metal, polyester로 구성된 머리카락 보다 가늘게 제작된 mesh로 시험관을 부분적으로 RF를 차폐하여 주변에 위치한 자기공명영상용 팬텀에 미치는 영향을 평가하고자 하였다. 3T Achieva X-series의 Cardiac Coil을 사용하여 TR 500 ms, TE 20 ms, NEX 1, slice thickness 5 mm의 Spin Echo T1강조영상에서 field of view(FOV)에 따른 자기공명영상을 분석하였다. FOV 304 mm × 304 mm에서는 발생하지 않았던 aliasing artifact가 발생하지 않았지만 250 mm × 250 mm 과 170 mm × 170 mm에서는 발생되었다. FOV 170 mm × 170 mm에서 mesh를 사용하지 않은 경우는 SNR이 78.23으로 가장 낮았으며, mesh를 가운데 세워 분리한 경우에는 215.05, mesh로 완전히 차폐한 경우에는 366.44로 높게 측정되었다. 또한 mesh로 완전히 감싸고 차폐한 경우에는 aliasing artifact도 제거되었고, 영상의 왼쪽과 가운데, 오른쪽의 신호 대 잡음비가 높으면서 다른 조건과 비교하여 균질한 영상을 획득할 수 있었다. 결론적으로 mesh로 RF를 부분적으로 감싸고 차단하면 aliasing artifact를 제거할 수 있고, 작은 FOV를 사용하여 영상의 해상도와 균질성이 우수한 자기공명영상을 획득할 수 있을 것으로 사료된다.

경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상 (Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections)

  • 정관진;김일영;이만우;이윤
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2002
  • Fourier 변환 동맥혈관 영상법(FTA)은 동맥혈류의 속도가 심장박동 주기와 동기화되어서 주기적으로 변화하는 사실에 착안하였다. Presaturation 기법에 의하여 정맥과 동맥을 분리하는 기존의 다른 혈관촬영법과는 본질적으로 다른 기술이다 따라서 생체조직의 고주파(RF) 흡수정도가 낮으며, 굽은 혈관이나 역류 현상으로부터 발생될 수 있는 어두운 띠 모양의 허상이 나타나지 않는다. 더욱이 강한 경사자기장을 사용하지 않음으로써 강한 경사자기장에 수반되는 와류현상에 의한 허상까지도 줄일 수 있는 장점이 있다. 그러나 하나의 투사 영상을 얻고, 영상 영역 내에서 혈류 유입부와 출구부의 혈류포화 현상에 의하여 신호강도가 상이한 단점이 있다. 이러한 단점들은 최근의 기술적 발전으로 극복될 수 있다. 현대 자기공명영상장치의 고속 경사자계 변화 능력으로 반복시간(TR)의 변화 없이 FTA 시퀀스에 이중 투사법을 적용할 수 있었다. 경사 고주파 전자기파(Ramped RF) 펄스를 사용하여 유입부와 출구부에서 숙임각을 달리하여 신호가 포화되는 정도를 줄여서 균일한 혈관신호를 얻을 수 있었다. 이중투사영상과 경사고주파 펄스를 사용하여 대퇴 동맥의 시상면과 관상면 투사영상을 동시에 얻고, 종래의 FTA 방식에 의한 영상보다 출구부의 혈관신호가 향상된 결과 영상을 얻을 수가 있었다.

  • PDF

침투성 동맥경화성 궤양과 흡사한 급성 A형 대동맥 박리증 -1l례 보고 - (Acute Type A Aortic Dissection Mimicking Penetrating Atherosclerotic Ulcer)

  • 최재성;곽재건;안혁
    • Journal of Chest Surgery
    • /
    • 제36권1호
    • /
    • pp.30-34
    • /
    • 2003
  • 급성 대동맥 박리증과 대동맥 침투성 궤양은 근내혈종과 함께 급성 대동맥 증후군을 구성하는 치명적 질환이나 그 병태생리와 자연경과가 다르고 치료전략이 다를 수 있어 정확한 감별진단을 요한다. 그러나 서로 임상양상이 비슷하고 초음파나 CT, MRI등의 진단방법으로도 명확히 구분이 안되는 경우가 많다. 환자는 약 10년간의 고혈압 병력이 있는 71세 여자로 내원 3일전에 갑자기 시작된 전흉부 통증 및 오심, 구토를 주소로 입원하였다. 전산화 단층촬영상에서 내막박리편은 보이지 않았으며, 상행대동맥 및 무명동맥간, 대동맥궁, 하행 흉부대동맥에 걸친 근내혈종(intramural hematoma)과 양측성 혈흉 및 혈성 심낭삼출 소견이 보였고, 무명 동맥간의 하방 약 1 cm 거리에 상행대동맥의 앞쪽으로 국소적인 궤양소견이 보여 상행대동맥에 생긴 침투성 궤양 및 이로인한 대동맥 파열로 진단하고 응급수술을 시행하였다. 그러나, 수술장 소견에서는 무명동맥 기시부 하방 1cm 정도에 약 0.5cm크기로 내막이 찢어져 있었고 외막을 열고 오래된 혈종을 제거하니 거의 폐쇄되어있던 가성내강이 관찰되었으며 이는 내막 파열 부위와 교통하였다. 이처럼 대동맥 박리증이 침투성 궤양과 흡사한 임상양상 및 진단 소견을 보일 수 있음을 경험하였기에 증례로 보고하는 바이다.

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol

  • Jo, Yeseul;Kim, JeongJae;Park, Chul Hwan;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Kim, Pan Ki;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.296-315
    • /
    • 2019
  • Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

High-Resolution Numerical Simulation of Respiration-Induced Dynamic B0 Shift in the Head in High-Field MRI

  • Lee, So-Hee;Barg, Ji-Seong;Yeo, Seok-Jin;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.38-45
    • /
    • 2019
  • Purpose: To demonstrate the high-resolution numerical simulation of the respiration-induced dynamic $B_0$ shift in the head using generalized susceptibility voxel convolution (gSVC). Materials and Methods: Previous dynamic $B_0$ simulation research has been limited to low-resolution numerical models due to the large computational demands of conventional Fourier-based $B_0$ calculation methods. Here, we show that a recently-proposed gSVC method can simulate dynamic $B_0$ maps from a realistic breathing human body model with high spatiotemporal resolution in a time-efficient manner. For a human body model, we used the Extended Cardiac And Torso (XCAT) phantom originally developed for computed tomography. The spatial resolution (voxel size) was kept isotropic and varied from 1 to 10 mm. We calculated $B_0$ maps in the brain of the model at 10 equally spaced points in a respiration cycle and analyzed the spatial gradients of each of them. The results were compared with experimental measurements in the literature. Results: The simulation predicted a maximum temporal variation of the $B_0$ shift in the brain of about 7 Hz at 7T. The magnitudes of the respiration-induced $B_0$ gradient in the x (right/left), y (anterior/posterior), and z (head/feet) directions determined by volumetric linear fitting, were < 0.01 Hz/cm, 0.18 Hz/cm, and 0.26 Hz/cm, respectively. These compared favorably with previous reports. We found that simulation voxel sizes greater than 5 mm can produce unreliable results. Conclusion: We have presented an efficient simulation framework for respiration-induced $B_0$ variation in the head. The method can be used to predict $B_0$ shifts with high spatiotemporal resolution under different breathing conditions and aid in the design of dynamic $B_0$ compensation strategies.

이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구 (The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique)

  • 염헌규;이종민;김용선;이상권;서경진;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 목적 : 인체의 심근 및 간조직의 생체내 $^{31}P$ MRS에서 NOE 효과에 의한 분광신호 세기의 증가를 평가하고자 하였으며 또한 동일 장기에서 대사물질에 따른 NOE 효과의 차이를 알아보고자 하였다. 대상 및 방법: 열명의 정상 성인군(남:여=8:2, 연령분포=24-32)을 대상으로 1.5T 자기공명영상/분광 장치에서 $^1H-^{31}P$ 이중 튜닝 표면 코일을 사용하여 생체내 $^{31}P$ MRS를 시행하였다. $^{31}P$ MRS 측정은 이차원 화학변위영상기법을 사용하였으며 동일한 파라미터에서 NOE 효과 없이 그리고 $^1H$ decoupling상태에서 NOE 효과에 의한 $^{31}P$ MRS 데이터를 획득하였다. $^{31}P$ MRS raw data의 postprocessing 후 얻어진 스펙트럼에서 주요 대사물질들의 신호증가를 비교하였다. 결과: 간조직의 $^{31}P$ HRS에서 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%),\;PME\;(31\%)$였다. 간조직의 경우 크리아틴 키나제가 없기 때문에 PCr 신호는 관찰되지 않았다. 심근의 $^{31}P$ MRS은 whole body 코일이 표면 코일보다 우수한 scout 영상을 제공하여 $^{31}P$ MRS의 localization에 유리하였다. $^{31}P$ 심근 다중 체적 스펙트럼에서 , 혈액의 DPG 신호는 심근으로부터 멀어질 수록 증가하는 양상을 나타내었고 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;PDE\;(51\%),\;DPG\;(72\%)$ 였다. 결론: 간조직에 비해 심근의 경우 큰 신호증가를 보였고 이는 간조직 대사물질들의 $^{31}P$가 심근과는 다른 $^1H$ coupling을 나타냄을 의미한다고 해석할 수 있다.

  • PDF