Abstract
The purpose of this study is to evaluate the effect on the phantom for magnetic resonance imaging located nearby by partially shielding RF with a mesh made thinner than hair composed of copper, black metal, and polyester using metallic materials of titanium, which are commonly used for esophageal stents and implants in the body. Magnetic resonance images according to field of view (FOV) were analyzed in the Spin Echo T1 weighted images of TR 500 ms, TE 20 ms, NEX 1, and slice thickness 5mm using a Cardiac coil of 3T Achieva X-series. Aliasing artifact did not occur in FOV 304 mm × 304 mm, but it occurred in 250 mm × 250 mm and 170 mm × 170 mm. In FOV 170 mm × 170 mm, when a mesh was not used, the SNR was measured with 78.23, and when separated by standing a mesh in the middle, it was 215.05, and when completely shielded with a mesh, the SNR was 366.44. In addition, when completely shielded with a mesh, the aliasing artifact was also removed, and signal intensities on the left, middle and right of the image were also able to obtain homogeneous images compared to the previous two cases. In conclusion, if RF is partially shielded with a mesh, aliasing artifact can be removed, and magnetic resonance images with excellent image resolution and homogeneity can be obtained using a small FOV.
Keywords
Magnetic Resonance Imaging(MRI); Mesh; Phantom; FOV; Aliasing artifacts;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. C. Sharp, S. B. King, Q. Deng, V. Volotovskyy, B. Tomanek, "High resolution MRI encoding using radiofrequency phase gradients", NMR in Biomedicine, Vol. 26, No. 11, pp. 1602-1607, 2013. http://dx.doi.org/10.1002/nbm.3023   DOI
2 R. Viola, B. P. Kim , "MR Thermometry", Journal of Magnetic Resonance Imaging, Vol. 27, No. 2, pp. 376-390, 2008. https://doi.org/10.1002/jmri.21265   DOI
3 P. G. Park, Y. G. Kim, S. W. Shin, "Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke", Journal of Korean Magnetic Society, Vol. 13, No. 6, pp. 251-256, 2003. http://dx.doi.org/10.4283/JKMS.2003.13.6.251   DOI
4 F. G. Shellock "MR imaging and cervical fixation devices: evaluation of ferromagnetism, heating, and artifacts at 1.5 Tesla", Magnetic resonance imaging, Journal of Magnetic Resonance Imaging, Vol. 14, No. 9, pp. 1093-1098, 1996. https://doi.org/10.1016/s0730-725x(96)00114-2   DOI
5 C. K. Chou, J. A. McDougall, K. W. Chan, "RF heating of implanted spinalfusion stimulator during magnetic resonance imaging", IEEE transactions on biomedical engineering, Vol. 44, No. 5, pp. 367-373, 1997. http://dx.doi.org/10.1109/10.568912   DOI
6 F. G. Shellock, S. Morisoli, E. Kanal, "MR procedures and biomedical implants, materials, and devices", Journal of Radiology, Vol. 189, No. 2, pp. 1587-599, 1993. http://dx.doi.org/10.1148/radiology.189.2.8210394   DOI
7 R. D. Venook, N. I. Matter, M. Ramachandran, S. E. Ungersma, G. E. Gold, N. J. Giori, A. Macovski, G. C. Scott, S. M. Conolly, "Prepolarized magnetic resonance imaging around metal orthopedic implants", Magnetic Resonance in Medicine, Vol. 56, No. 1, pp. 177-186, 2006. http://dx.doi.org/10.1002/mrm.20927   DOI
8 J. T. McFadden, "Magnetic resonance imaging and aneurysm clips : A review", Journal of Neurosurgery, Vol. 117, No. 1, pp. 1-11, 2012. http://dx.doi.org/10.3171/2012.1.JNS111786   DOI
9 L. Kang, K. W. Choi, H. B. Lee, S. R. Na, S. W. Yang, D. K. Seo, "An Effectiveness of Radio Frequency(RF) Shielding Fibers and Customized RF Protective Clothing Applied to the Whole Body in Partial Area Imaging Working as a RF Absorber", Journal of The Korean Society of MR Technology, Vol. 27, No. 2, pp. 45-57, 2017. http://dx.doi.org/10.31159/ksmrt.2017.27.2.45   DOI
10 G. W. Choi, J. H. Seo, C. H. Oh, "Study on RF Transmission Shielding for Localized Field-Of-View MRI", The Korean Institute of Electrical Engineers, Vol. 10, No. 11, pp. 276-277, 2010.
11 Jana Starcukova, Zenon Starcuk, Hana Hubalkova, Igor Linetskiy, "Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts", Dental materials, Vol. 24, No. 6, pp. 715-723, 2007. http://dx.doi.org/10.1016/j.dental.2007.07.002   DOI
12 Frank G. Shellock, Emanuel Kanal, "Burns associated with the use of monitoring equipment during MR procedures", Journal of Magnetic Resonance Imaging, Vol. 6, No. 1, pp. 271-272, 1996. http://dx.doi.org/10.1002/jmri.1880060150   DOI
13 D. Y. Choe, D. H. Kim, "Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program", Journal of the Korean society of Radiology, Vol. 11. No. 5, pp. 361-370, 2017. http://dx.doi.org/10.7742/jksr.2017.11.5.361   DOI