• 제목/요약/키워드: Cardiac MRI

검색결과 105건 처리시간 0.021초

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

심장 전산화단층촬영을 이용한 박출계수 산출 시 박출계수의 보정을 통한 오진율 개선에 관한 연구 (A Study on Misdiagnosis Rates of Ejection Fraction Associated with Cardiac Computed Tomography: Suggestions and Correction for Improvement)

  • 나사라;정미애
    • 한국콘텐츠학회논문지
    • /
    • 제21권2호
    • /
    • pp.437-444
    • /
    • 2021
  • 본 연구는 cardiac CT를 이용한 박출계수 산출 시 cardiac MRI와 물리적 시간 해상도 차이를 분석하여 보정함으로써 cardiac CT의 오진율을 감소시키고자 하였다. 연구 방법은 대동맥판막 역류 질환을 진단받은 138명을 대상으로 cardiac CT와 cardiac MRI의 박출계수를 산출한 후 두 검사 간 물리적 시간 해상도 차이를 cardiac CT의 박출계수에 보정한 다음 신뢰도를 평가하여, 물리적 시간 해상도 차이 보정 전, 후 cardiac CT의 오진율이 개선됐는지 평가 하였다. 연구결과, 물리적 시간 해상도 차이 보정 전 cardiac CT 박출계수의 오진율은 38.4%(53명)로 높게 나왔고, 보정 후 오진율은 23.9%(33명)로 감소하였다. 또한 Bland-Altman plot에서 확인한 보정된 cardiac CT 박출계수는 cardiac MRI의 박출계수와의 일치도가 상당히 높은 것을 알 수 있다. 결론적으로 심장판막 질환 진단시 단순한 cardiac CT의 박출계수로만 진단하는 것은 오진율을 높일 수 있으므로 cardiac MRI로 물리적 시간 해상도의 차이를 보정하면 오진율을 14.5%(20명) 감소시킬 수 있다. 그러므로 본 연구를 박출계수 산출 시 적용한다면 유용성이 높다고 사료된다.

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.102-113
    • /
    • 2019
  • Objective: To assess the accuracy and potential bias of computed tomography (CT) ventricular volumetry using semiautomatic three-dimensional (3D) threshold-based segmentation in repaired tetralogy of Fallot, and to compare them to those of two-dimensional (2D) magnetic resonance imaging (MRI). Materials and Methods: This retrospective study evaluated 32 patients with repaired tetralogy of Fallot who had undergone both cardiac CT and MRI within 3 years. For ventricular volumetry, semiautomatic 3D threshold-based segmentation was used in CT, while a manual simplified contouring 2D method was used in MRI. The indexed ventricular volumes were compared between CT and MRI. The indexed ventricular stroke volumes were compared with the indexed arterial stroke volumes measured using phase-contrast MRI. The mean differences and degrees of agreement in the indexed ventricular and stroke volumes were evaluated using Bland-Altman analysis. Results: The indexed end-systolic (ES) volumes showed no significant difference between CT and MRI (p > 0.05), while the indexed end-diastolic (ED) volumes were significantly larger on CT than on MRI (93.6 ± 17.5 mL/m2 vs. 87.3 ± 15.5 mL/m2 for the left ventricle [p < 0.001] and 177.2 ± 39.5 mL/m2 vs. 161.7 ± 33.1 mL/m2 for the right ventricle [p < 0.001], respectively). The mean differences between CT and MRI were smaller for the indexed ES volumes (2.0-2.5 mL/m2) than for the indexed ED volumes (6.3-15.5 mL/m2). CT overestimated the stroke volumes by 14-16%. With phase-contrast MRI as a reference, CT (7.2-14.3 mL/m2) showed greater mean differences in the indexed stroke volumes than did MRI (0.8-3.3 mL/m2; p < 0.005). Conclusion: Compared to 2D MRI, CT ventricular volumetry using semiautomatic 3D threshold-based segmentation provides comparable ES volumes, but overestimates the ED and stroke volumes in patients with repaired tetralogy of Fallot.

A Study on Comparison of Cardiac Ejection Fraction Values Measured in Myocardium SPECT and Cine MRI

  • Han, Jung-Seok;Dong, Kyung-Rae;Park, Yong-Soon;Chung, Woon-Kwan;Cho, Jae-Hwan;Cho, Young-Kuk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.229-232
    • /
    • 2012
  • This study examined the correlation between MR cine and myocardium Single-photon emission computed tomography (SPECT) by comparing the measured cardiac ejection fractions. The usefulness of cardiac MRI was also evaluated. Ten patients (8 men, 2 women and average age of 58.6 years), who underwent a myocardium SPECT scan and cardiac cine MRI scan among patients who visited the hospital for the chief complaint of cardiac disorder from June 1, 2010 to February 10, 2011, were enrolled in this study. The cardiac ejection fraction was calculated from the images obtained in both scans. The data was used to examine the correlation. The regression equation the cardiac ejection fraction values of the 10 patients obtained in myocardium SPECT and MRI cine was Y = 1.12X-8.91 ($R^2$ = 0.78, significance of F = 0.001639, and confidence level of 95%). The results were significant when the cardiac ejection fraction obtained from MRI cine was compared with that obtained from myocardium SPECT. Overall, a cardiac examination using MRI enables an investigation of not only the ejection fraction but also the ED and ES volumes, stroke volume, wall thickness, and wall thickening in a higher spatial resolution despite the examination being conducted once. This examination is believed to be very useful for diagnosing patients with cardiac disease.

심장 자기공명영상 (Cardiac MRI)

  • 이종민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 심장의 영상화에 장애가 되는 요인은 심장 운동, 호흡, 심장 내 혈류 등에 의한 인공물(artifact) 과 심장 조직의 용적이 작음으로 인한 낮은 신호 대 잡음비 등이 있다. 심장 운동에 의한 화질 저하를 막기 위해 신속영상기법(fast imaging technique) 을 이용하여 심장 운동의 특정 위상(phase) 에서만 영상을 얻는 심장동기(cardiac gating) 방법을 이용하고 있다. MRI를 이용한 심장의 검사는 심장의 형태, 심실 기능, 심근 관류, 심근 대사, 관상동맥 영상 등을 대상으로 한다. 심장의 형태적 진단에 있어서 심근내 수분의 정도와 지방조직을 보기 위해 이중(double) 혹은 삼중역전회복기법(triple inversion recovery technique) 을 사용한다. 심근관류검사를 위해서는 조영증강신속경사에코법(contrast-enhanced fast gradient echo technique)을 사용하여 일차통과조영증강(first-pass enhancement) 을 검사한다. 또한 10-15분 지연영상을 얻어 심근내 조영제의 재분포를 검사하여 만성심근경색 등의 심근파괴부위를 확인한다. 심실기능 평가를 위해서는 신속경사에 코법을 이용한 영화영상(cine image) 이 사용되며 심실의 국소적 운동이상 및 심실기능의 정량적 검사가 가능하다. MRI는 관상동맥영상을 제외한 포괄적 심장검사에 실용성이 있다. 특히 지연영상은 다른 검사장비에선 얻을수 없는 유용한 정보이다.

  • PDF

심장 MRI 영상에서 혈류 윤곽선의 자동 추출 (An Automatic Extraction of Blood Flow Contour from Cardiac MRI)

  • 이형직;조상현;최흥문
    • 전자공학회논문지SC
    • /
    • 제37권5호
    • /
    • pp.56-62
    • /
    • 2000
  • 본 논문에서는 심장 MRI 영상에서 혈류 윤곽선을 자동으로 추출하는 방법을 제안하였다. 제안한 방법에서는 기존 snake 보다 포획 범위가 넓은 GVF(gradient vector flow) snake를 사용하고, 심장 MRI의 에지 영상에서 GVF 계(field)가 영인 영역의 외곽을 따라 초기점들을 자동 발생시킴으로써, 전문가의 수작업 초기화에 의존하던 기존 방법과는 달리, 유두근으로 인한 요면을 갖는 혈류 윤곽선까지도 자동으로 추출할 수 있도록 하였다. 유두근 돌출로 인한 요면을 가지거나 잡영이 섞여있는 실제 심장 MRI들에 대해 실험하여 혈류 윤곽선을 효과적으로 자동 추출할 수 있음을 확인하였다.

  • PDF

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

Cardiac MRI를 이용한 심박출계수의 평가 (Evaluation of Cardiac Ejection Fraction using Cardiac MRI)

  • 은성종;국진선
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.289-294
    • /
    • 2011
  • 본 연구의 목적은 cardiac MRI를 이용하여 확장기와 수축기의 정량적 측정을 통해 각 단면의 심박출률의 차이를 알아보고자 하였다. 총 12명(정상 7명, 심근교 1명, 부정맥 4명)을 대상으로 심첨에서부터 대동맥궁 쪽으로 단면을 얻었다. 수축기와 확장기 영상을 확대하여 경계를 정하였고, 이 면적을 바탕으로 1, 3, 5, 6-7단면의 심박출률을 구하였다. 정상인의 평균 박출률은 각각 1, 3, 5, 6-7단면에서 67.14%, 66.24%, 65.63%, 그리고 65.29% 로 나타났다. 반면, 환자들의 평균 박출률은 각각 1, 3, 5, 6-7단면에서 61.74%, 60.92%, 60.89%, 그리고 61.89%로 나타났다. 본 연구를 통해 cardiac MRI를 이용한 특정단면의 심박출률은 각 단면마다 큰 차이가 없음을 알 수 있었고 따라서 cardic MRI를 이용한 심박출계수의 평가는 대표 단면만으로 가능함을 알 수 있었다.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.