• Title/Summary/Keyword: Cardiac Function

Search Result 556, Processing Time 0.033 seconds

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

Effects of Gastrodia Rhizoma Extracts on Global Coronary Circulation in Rats (천마 Extracts가 백서의 국소적 관상순환기능에 미치는 영향)

  • Kim, Eun-Ji;Ji, Geun-Eog;Kang, Young-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.213-220
    • /
    • 1994
  • Gastrodia (G) Rhizoma has been used clinically as an oriental herbal medicine with sedative, anticonvulsive, and depressor effects. The present study tested effects of G. Rhizoma extracts on the coronary circulation and myocardial oxygen consumption in perfused rat hearts. Sprague Dawley rats (SD) and spontaneously hypertensive rats (SHR) were employed as experimental animals and nonworking Langendorff heart perfusion technique introduced for heart experiments. G. Rhizoma extracts were prepared from grinding G. Rhizoma into powder, extracting in water and 50% ethanol for 4 or 16 hr and diluting with Krebs-Henseleit bicarbonate perfusion buffer to be 70%. Hearts were perfused with bicarbonate buffer oxygenated with 95% $O_{2}:$ 5% $CO_{2}$ at constant coronary perfusion pressure of $90cmH_{2}O$. The diluted extracts were infused into coronary arteries in a concentration of $1{\sim}5\;{\mu}M$ for $7{\sim}8 min. While in SD water- or ethanol-extracts of G. Rhizoma extracted for 16 hr increased coronary perfusate flow (CPF) and decreased coronary vascular resistance (CVR), ethanol-extracts in SHR produced coronary vasoconstriction associated with enhanced CVR. G. Rhizoma extracts-induced increase in CPF reduced myocardial oxygen extraction, and thus myocardial oxygen consumption ($MVO_{2}$) remained at that observed prior to infusion of extracts. In SD and SHR 16 hr-water-extracts markedly altered coronary venous effluent pH and $Pco_{2}$ and evoked metabolic acidosis, which could be a coronary vasodilator mechanism decreasing CVR. In this study, the extracts decreasing CVR in SD and SHR did not augment the lactate production. Therefore, although the effects of the extracts on cardiac function and coronary circulation depended on solvents and duration for extraction, the 16hr-water-extracts, at least, exhibited coronary vasodilation in SD and SHR. Conversely, ethanol-extracts constricted coronary arteries in SHR. G. Rhizoma extracts-induced vasodilation might be due to the metabolic acidosis rather than due to the increased lactate production. The results indicate that G. Rhizoma extracts obtained from proper extracting procedures can be used as a safe and clinically applicable herbal medicine in the cardiovascular diseases such as coronary artery disease and hypertension for vasodilatory and antihypertensive actions.

  • PDF

Clinical Application of Compressed Spectral Array During Deep Hypothermia (초저체온하 대동맥수술 환자에서 완전 순환차단의 안전한 체온 및 기간에 대한 연구 - 뇌파 Compressed Spectral Array의 임상적 응용 -)

  • 장병철;유선국
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.752-759
    • /
    • 1997
  • Profound hypothermia protects . cerebral function during total circulatory arrest(TCA) in the surgical treatment of a variety of cardiac and aortic diseases. Despite its importance, there is no ideal technique to monitor the brain injury from ischemia. Since 1994, we have developed compressed spectral array(CSA) of electroencephalography(EEG) and monitored cerebral activity to reduce ischemic injury. The purposes of this study are to analyse the efficacy of CSA and to establish objective criteria to consistently identify the safe level of temperature and arrest time. We studied 6 patients with aortic dissection(AD, n=3) or aortic arch aneurysm(n=3, ruptured in 2). Body temperatures from rectum and esophagus and the EEG were monitored continuously during cooling and rewarming period. TCA with cerebral ischemia was performed in 3 patients and TCA with selective cerebral perfusion was performed in 3 patients. Total ischemic time was 30, 36 and 56 minutes respectively for TCA group and selective perfusion time was 41, 56 and 92 minutes respectively for selective perfusion group. The rectal temperatures for flat EEG were between 16.1 and 22. $1^{\circ}C$ (mean: 18.4 $\pm$ 2.0): the esophageal temperatures between 12.7 and $16.4^{\circ}C$ (mean $14.7\pm1.6).$ The temperatures at which EEG reappeared $5~15.4^{\circ}C$ for esophagus. There was no neurological defic t and no surgical mortality in this series. In summary, the electrical cerebral activity Teappeared within 23 minutes at the temperature less than $16^{\circ}C$ for rectum. It seemed that $15^{\circ}C$ of esophageal temperature was not safe for 20 minutes of TCA and continuous monitoring the EEG with CSA to identify the electrocerebral silence was useful.

  • PDF

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.

Early Hemodynamic Changes and Short-term Outcomes of Mitral Valvuloplasty versus Replacement with Chordal Preservation for Patients with Mitral Regurgitation (승모판막폐쇄부전 환자에서 판막성형술과 판막대치술이 수술 후 혈역학과 단기 예후에 미치는 영향 비교)

  • Choi, Yong-Seon;Kwak, Young-Lan;Chang, Byung-Chul;Kim, Ji-Ho;Hong, Yong-Woo;Bang, Sou-Ouk
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.659-666
    • /
    • 2007
  • Background: Preserving the subvalvular apparatus after mitral valve replacement (MVR) results in better ventricular function and a better outcome. In conjunction, mitral valve repair (MVr) is associated with a better outcome, yet little is known about the hemodynamics and outcomes between patients undergoing MVr and MVR with chordal preservation. We prospectively evaluated the hemodynamic changes and outcomes of patients undergoing MVr and MVR with chordal preservation. Material and Method: Fifty-four patients with mitral regurgitation (MR) who under-went MVR with chordal preservation (n=21) or MVr (n=33) were studied. The patients' characteristics, the intra-and postoperative hemodynamics and the use of cardiac medications, the postoperative outcome and the complications were recorded during the hospital stay. All the patients were followed up for at least 6 months post-operatively for determining their morbidity and mortality. Result: The patients' characteristics were similar between the groups, except for the presence of atrial fibrillation and congestive heart failure which was more frequent in the MVR group. Also, the preoperative left ventricular ejection fraction was lower in the MVR group than in the MVr group ($64{\pm}9%$ versus $69{\pm}5%$, respectively, p=0.043). There were no significant differences of the hemodynamics between the groups. The use of inotropic drugs and pacemakers during the 12hrs postoperatively was more common in the MVR group than in the MVr group (48% versus 24%, p=0.025 and 52% versus 24%, p=0.035, respectively). The other postoperative outcomes were similar in both groups for at least the 6 months follow-up period. Conclusion: MVR with chordal preservation was comparable with regard to the hemodynamics and clinical outcomes, supporting the beneficial effect of preserving the subvalvular apparatus after MVR.

Drugs Most Frequently Used in OPD of Yeungnam University Hospital: March to August, 1985 (영남대학교 의과대학 부속병원 외래환자에 대한 약물처방 동향의 분석)

  • Lee, Kwang-Youn;Kim, Won-Joon;Kim, Sung-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.95-102
    • /
    • 1985
  • This report offers descriptive data about the drugs utilized in out patient department (OPD) of Yeungnam University Hospital (YUH) in the period of march to august in 1985. The data in this report were produced by the computerized totalization of the number of mentions of individual drugs included in the prescriptions. The 100 drug entries that were most frequently recorded are listed in rank order. The listing is arbiturarily restricted to the drugs that were prescribed as single preparations, the drugs of basis of compound preparations and the drugs of adjuvent or corrective of compound preparations that have significant therapeutic effects either by generic names. And in addition, the listing also involves the compound preparations used in relatively large frequency, and the individual components of which have the unique pharmacological actions each other by proprietary names. And all routes of administrations were allowed. The 10 drugs most frequently named are diazepam, aluminum compounds, acetaminophen, isoniazid, metoclopramide, $polaramine^{(R)}$, carboxymethylcystem, ephedrine, codeine and caroverine in order. The 521,855 drug mentions listed as above are described by the chief therapeutic usage that each is intended to apply generally. The drugs which account the largest proportion of total mentions were those acting on the central nervous system (20.57%), including tranquilhzers and sedative hypnotics (11.71%), analgesic antipyretics (5.55%), antidepressants (2.15%) etc. Gastrointestinal drugs and smooth muscle preparations (18.64%) included antacids and anti-ulcer drugs (9.24%), antiemetics (3.57%), spasmolytics (3.14%) and others. Respiratory drugs (16.11%) included expectorants and cough preparations (10.99%) and bronchodilators (5.12%). Chemotherapeutic agents (15.12%) included the antiTbc drugs (7.09%) most frequently, and the penicillins (3.33%) accounted the largest proportion among the antibiotics. Cardiovascular drugs (5.64%) included cardiac drugs and coronary vasodilator (4.12%) and antihypertensives and vasodilators (1.06%). And anti-inflammatory drugs (4.33%), vitamins of single preparations (3.76%), hormones and their antagonists (3.29%), common cold preparations (3.12%), diuretics (2.81%), drugs supporting liver function (2.02%), drugs affecting autonomic nervous system(1.89%) including anti-glaucomas, atropine and cerebral vasodilators, antihistamine drugs (1.02%) and disinfectants (0.74%) were following in order. The data in this report were compared to those reported by H. Koch, et al. in United States (US), 1981 as "Drugs Most Frequently Used in Office Practice:National Ambulatory Medical Case Survey, 1981." Cardiovascular drugs prescribed in YUH were much less in proportion than in US (10.56%), but gastrointestinal drugs accounted the larger proportion than in US (3.72%). Expectorants and cough preparations in YUH also accounted the larger proportion than in US (2.74%). In conclusion, in the period of march to august, 1985, OPD of YUH prescribed the CNS drugs including diazepam most frequently, and gastrointestinal, repiratory and chemotherapeutic drugs in next orders. It is supposed that the eating habits of Koreans and a unique atmospheric condition in Taegu as a basin were some important factors that affected the proportions of drugs acting on gastrointestinal and respiratory tracts.

  • PDF

A Comparison of the Effects of Histidine-tryptophan-ketoglutarate Solution versus Cold Blood Cardioplegic Solution on Myocardial Protection in Mitral Valve Surgery (승모판막수술 시 히스티딘를 함유한 결정성 심정지액(Histidine-tryptophan-ketoglutarate Solution)과 저온 혈성 심정지액이 심근기능 보존에 미치는 영향 비교)

  • Choi, Yong-Seon;Bang, Sou-Ouk;Chang, Byung-Chul;Lee, Sak;Park, Chol-Hee;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.399-406
    • /
    • 2007
  • Background: Ischemia-reperfusion injury related to unsuccessful myocardial protection affects postoperative ventricular function and mortality during open-heart surgery. We prospectively compared the effects of administration of histidine-tryptophan-ketoglutarate (HTK) solution and cold blood cardioplegia (CBC) on myocardial protection and clinical outcome in patients undergoing mitral valve surgery. Material and Method: Seventy patients with mitral regurgitation (MR) undergoing mitral valve surgery were randomly divided into the HTK group (n=31) and the CBC group (n=31 ): eight patients were excluded. Perioperative hemodynamics, cardiac medications, pacing, postoperative outcomes and complications were recorded during the hospital stay. All patients received follow-up for at least 6 months postoperatively for morbidity and mortality. Resuか: There were no significant differences in the hemodynamics between the groups during the study period, except for the mean pulmonary artery pressure (MPAP), PCWP and CVP that were lower in the HTK group at 15 min after weaning of CBP. There were no differences for inotropic support and pacing during the 12 hrs postoperatively between the groups. CK-MB values on day 1 and day 2 were $77{\pm}54$ and $41{\pm}23$ for the HTK group and $70{\pm}69$ and $44{\pm}34$ for the CBC group, respectively (p=NS). Postoperative clinical outcomes were similar in both groups for at least 6 months during the follow-up period. Conclusion: These results suggest that the use of HTK solution is as safe as cold blood cardioplegia in terms of myocardial protection.

Comparison of Electrocardiographic Time Intervals, Amplitudes and Vectors in 7 Different Athletic Groups (운동종목별(運動種目別) 선수(選手)의 심전도시간간격(心電圖時間間隔), 파고(波高) 및 벡터의 비교(比較))

  • Kwon, Ki-Young;Lee, Won-Jung;Hwang, Soo-Kwan;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.61-72
    • /
    • 1985
  • In order to compare the cardiac function of various groups of athletes, the resting electrocardiographic time intervals, amplitudes and vectors were analyzed in high school athletes of throwing(n=7), jumping(n=11), short track(n=8), long track(n=14), boxing(n=7), volleyball(n=8) and baseball(n=9), and nonathletic control students(n= 19). All athletic groups showed a significantly longer R-R interval(0.96-1.09 sec) than the controls (0.78 sec). Therefore, the heart rate was significantly slower in atheletes than in the control, but was not different among the different athletic groups. R-R interval is the sum of intervals of P-R, 0-T and T-P: P-R and Q-T intervals showed no difference among the control and athletic groups, but T-P interval in the jump, short track, long track and boxing groups was significantly higher than the control. R-B interval showed a significant correlation with T-P or Q-T intervals but no correlation with P-R or QRS complex. Comparing the amplitude of electrocardiographic waves, the athletic groups showed a lower trend in P wave than the controls. T wave in lead $V_5\;(Tv_5)$ was similar in the athletic and control groups. The long track group showed a significantly higher waves of $Rv_5$, $Sv_1$, and the sum of $Rv_5$ and $Sv_1$ than not only the controls but also the other athletic group. The angles of P, QRS, and T vector in the frontal and horizontal planes were not different among the control and all the athletic groups. Each athletic group stowed a lower trend in amplitude of P vector in the frontal plane, but in horizontal plane, throwing, jump, short track and baseball groups showed a significantly lower than the controls. The amplitude of QRS and T vector was similar in the athletic and control groups, but only the baseball group showed a significantly higher QRS vector in the frontal plane. In taken together, all the athletic groups showed a slower heart rate than the controls, mainly because of elongated T-P interval. Comparing the electrocardiographic waves and vector, the athletic groups showed lower amplitudes of P wave and P vector than the controls. Values of $Rv_5$ and $Sv_1$ strongly suggest that only the long distance runners among the various athletic groups developed a left ventricular hypertrophy.

  • PDF

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.