• Title/Summary/Keyword: Carbon monoxide (CO)

Search Result 572, Processing Time 0.034 seconds

Analysis of Patients with Acute Carbon Monoxide Poisoning in one Hospital (일개 병원에서의 일산화탄소 중독증으로 내원한 환자에 대한 분석)

  • Kim Kyung Hwan;Kim Ah Jin;Shin Dong Wun;Rho Jun Young
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2005
  • Purpose: The frequency of carbon monoxide poisoning has been decreased in the interior of the Korea. But occasionally it is occurred and the risk of exposure is high in working place so far. Because of the characteristics of gas, the detection of exposure and poisoning could be delayed and fatality is high. We should apprehend of carbon monoxide poisoning. So we would report analysis of patients with carbon monoxide poisoning. Methods: A retrospective review of CO poisoned patients visited emergency department from January 2000 to December 2004 was conducted. Results: 24 patients were enrolled. Their average of age was $37.6\pm20.9$ years old and COHb was $19.4\pm13.32\%$. The blood level of initial COHb and mental status on arrival were not correlated each other. The blood level of initial COHb and loss of consciousness were not correlated, too. Initial electrocardiography (EKG) was not correlated with cardiac enzymes such as CK-MB and troponin I. But base excess was correlated with mental status on arrival and complication such as rhabdomyolysis. Hyperbaric oxygen therapy was correlated with base excess and mental status on arrival. Conclusion: The clinical features of carbon monoxide poisoning are nonspecific. For proper diagnosis, it is important that we should consider patient's environment and take patient's history carefully. The blood level of initial COHb does not reflect severity of poisoning accurately. So We should determine the treatment of choice depending on patient's status.

  • PDF

EPR Studies of the Active Sites of Carbon Monoxide Dehydrogenase from Clostridium thermoaceticum

  • Shin, Woonsup;Lindahl, Paul A.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.869-876
    • /
    • 1995
  • The active sites of the nickel and iron-containing enzyme, carbon monoxide dehydrogenase (CODH) from clostridium thermoaceticum were investigated using Electron Paramagnetic Resonance (EPR) technique. CODH exhibits several spectral features called NiFeC, $g_{ave}=1.82$, $g_{ave}=1.86$. FCII signals which are originated from different clusters in this enzyme. CODH is know to catalyze two different kinds of reactions - acetyl-CoA synthesis and CO oxidation. The acetyl-CoA synthesis activity can be followed by monitoring CO/acetyl-CoA exchange. The addition of 1,10-phenanthroline (phen) to CODH selectively destroyed the CO/acetyl-CoA exchange activity and eliminated the NiFeC signal completely. CO oxidation activity and other EPR signals were unaffected. Such behavior demonstrates that CODH has two distinct active sites and that the NiFe complex is only responsible for the CO/acctyl-CoA exchange activity. Phen caused the removal of only 30% of Ni in the NiFe complex ($0.3Ni/{\alpha}{\beta}$) as shown by the quantitative metal analysis. The phen-treated CODH could be reactivated fully by incubation In $Ni^{2+}$ solution. Radioactive $^{63}Ni^{2+}$ was used to quantitate the amount of the $Ni^{2+}$ incorporated into phen-treated enzyme and showed that the amount was the same as the removed by the phen treatment. i.e. $0.3Ni/{\alpha}{\beta}$. This indicates that only 30% of NiFe complexes are labile and responsible for the CO/acctyl-CoA exchange activity, the other 70% are non-labile and have no exchange activity. This is the first clear evidence that the NiFe complex is heterogencous and labile and non-labile Ni sites arc interacting differently with substrates and chelating agents like phen.

  • PDF

Characterization of Graphene Sheets Formed by the Reaction of Carbon Monoxide with Aluminum Sulfide

  • Yoon, Il-Sun;Kim, Chang-Duk;Min, Bong-Ki;Kim, Young-Ki;Kim, Bong-Soo;Jung, Woo-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.3045-3048
    • /
    • 2009
  • Graphene sheets formed by the reaction of carbon monoxide (CO) with aluminum sulfide ($Al_2S_3$) at reaction temperatures ${\leq}$ 800 $^{\circ}$ were characterized by X-ray diffraction (XRD), Raman spectroscopy, and high-resolution transmission electron microscopy (HRTEM). The graphene sheets, formed as CO was reduced to gaseous carbon by the reaction with $Al_2S_3$, in the temperature range 800 - 1100 $^{circ}C$, did not exhibit their characteristic XRD peaks because of the small number of graphene layers and/or low crystallinity of graphene sheets. Raman spectra of graphene sheets showed that the intensity ratio of the D band to the G band decreased and the 2D band was shifted to higher frequencies with increasing reaction temperature, indicating that the number of graphene layers increased with increasing reaction temperature.

Cardiovascular Manifestations and Clinical Course after Acute Carbon Monoxide Poisoning (급성 일산화탄소 중독에 의한 심혈관계 독성의 임상 양상 및 경과)

  • Lee, In Soo;Jung, Yoon Seok;Min, Young Gi;Kim, Gi Woon;Choi, Sang Cheon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.2
    • /
    • pp.103-110
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the cardiovascular manifestations and clinical course in patients with acute carbon monoxide poisoning. Methods: A retrospective study was conducted over a 36 month period on consecutive patients who visited an emergency medical center and were diagnosed with acute carbon monoxide poisoning. A standardized data extraction protocol was performed on the selected patients. Results: A total of 293 patients were selected during the study period. Cardiac manifestations were observed in 35.2% (n=103) of the patients: hypotension in 11 patients (3.8%), ECG abnormalities in 44 patients (15.0%) and cardiac enzyme abnormalities in 103 patients (35.2%). Echo cardiography was performed on 56 patients with cardiac toxicity: 12 patients had abnormal results (5 patients with global hypokinesia and 7 patients with regional wall akinesia). Five patients died within 3 hours after ED admission, and the remaining patients were discharged alive. At 3 months after discharge, none of these patients had died.The SOFA scores in the severe cardiac toxicity group and non-severe cardiac toxicity group at the time of arrival were $2.53{\pm}2.29$ and $2.19{\pm}2.12$, respectively (p=0.860). Conclusion: Cardiovascular manifestations occur after acute CO poisoning at arateof 35.2%. Even those with severe cardiovascular toxicity recovered well within 10 days after admission. Therefore, the importance of cardiac toxicity after acute CO poisoning is not significant in itself in the clinical course, and the short-term prognosis of cardiac toxicity is unlikely to be unfavorable in acute CO poisoning.

  • PDF

Palladium-Catalyzed Carbonylative Homocoupling Reaction of Vinylmercuric Chlorides with Carbon Monoxide (팔라듐 촉매를 이용한 Vinylmercuric-chlorides 의 CO 첨가 호모커플링반응)

  • KimJin-Il 김진일;Kwang-Hyek Lee
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.657-661
    • /
    • 1989
  • Symmetrical divinyl ketone or divinyl ${\alpha}$-diketone was synthesized in moderately good yields through palladium catalyzed carbonylative homocoupling reaction of vinylmercuric chlorides with carbon monoxide. In order to find out optimum synthetic reaction conditions, we examined the effect of catalysts, bases, solvents and reaction temperature when (E)-styrylmercuric chloride was used as a typical starting material. The best yield of divinyl ${\alpha}$-diketone was obtained in the reaction using 10 mol% of dichlorobis(triphenyl phosphine)palladium (II) as a catalyst, an equivalent of pyridine as a base, 10 mol% of iodine and acetonitrile at 50${\circ}$C under 10 atmospheric pressure of carbon monoxide. The yield of divinyl ${\alpha}$-diketone was decreased under atmospheric pressure of carbon monoxide.

  • PDF

Analysis of Tropospheric Carbon Monoxide over East Asia

  • Lee, S.H.;Choi, G.H.;Lim, H.S.;Lee, J.H.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.615-617
    • /
    • 2003
  • Carbon monoxide (CO) is one of the important trace gases because its concentration in the troposphere directly influences the concentrations of tropospheric hydroxyl (OH), which controls the lifetimes of tropospheric trace gases. CO traces the transport of global and regional pollutants from industrial activities and large scale biomass burning. The distributions of CO were analyzed using the MOPITT data for East Asia, which were compared with the ozone distributions. In general, seasonal CO variations are characterized by a peak in the spring, which decrease in the summer. The monthly average for CO shows a similar profile to that for O$_3$. This fact clearly indicates that the high concentration of CO in the spring is possibly due to one of two causes: the photochemical production of CO in the troposphere, or the transport of the CO into East Asia. The seasonal cycles for CO and O$_3$ in East Asia are extensively influenced by the seasonal exchanges of different air mass types due to the Asian monsoon. The continental air masses contain high concentrations of O$_3$ and CO, due to the higher continental background concentrations, and sometimes to the contribution from regional pollution. In summer this transport pattern is reversed, where the Pacific marine air masses that prevail over Korea bring low concentrations of CO and O$_3$, which tend to give the apparent summer minimums.

  • PDF

A Study on the Standard for Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치기준에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the last five years, 36 people died and 79 were wounded because of carbon monoxide poisoning accident. A CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread mechanism of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. A CO gas leaked form exhaust tube in a building was the highest concentrated near the ceiling. CO alarm sets installation test confirmed that the alarm sets near the ceiling operated first, and the bottom and middle sets operated after $30{\sim}40$ minutes. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

A Study on Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Oh, Jeong-Seok
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Motor and Sensory Peripheral Neuropathy in a Patient Came after Acute Carbon Monoxide Intoxication: a Case Report with Magnetic Resonance Image

  • Lee, Seungmin;Kim, Sang Yoon;Lee, Jee Young;Choi, Min Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2016
  • Carbon monoxide (CO) intoxication is a leading cause of the variable neuropsychiatric impairment. Despite of widely known central nerve system complications after CO intoxication, peripheral neuropathy due to CO poisoning is rare and has been under-recognized. We report interesting case of a 29-year-old male who suffered from motor weakness and sensory abnormalities in his lower extremity following acute CO intoxication. The patient revealed direct and indirect signs of peripheral neuropathy of the left inferior gluteal and sciatic nerve on magnetic resonance imaging.

Prediction Performance of FDS on the Carbon Monoxide Production in the Under-Ventilated Fires (환기부족 화재에서 일산화탄소 발생에 대한 FDS의 예측성능)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.93-99
    • /
    • 2011
  • In the present study, a numerical simulation was conducted to estimate the prediction performance of FDS on the carbon monoxide production in the under-ventilated compartment fires. Methane and heptane fires located in the a 2/5 scale compartment based on the ISO-9705 standard room was simulated using FDS Ver. 5.5. Through the comparison between the computed results and the earlier published experimental data, the performance of FDS was estimated on the predictions of the combustion gases concentration in the hot upper layer of the compartment and the effects of CO yield rate on the estimation of CO production at local points were analyzed. From the results, it was known that FDS Ver. 5.5, in which the two-step reaction mixture fraction model implemented, was more effective on the prediction of CO concentration compared to the previous FDS version. In addition, controlling CO yield rate made the predicted CO concentration get closer to the experimental data for the fires of the under-ventilated condition.