• Title/Summary/Keyword: Carbon monoxide (CO)

Search Result 570, Processing Time 0.034 seconds

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

A Study on the Oxidation of Carbon Monoxide for Exhaust of Car Engine by the $LaSrNiCoO_3$ Low Noble Metal Catalyst (저귀금속 $LaSrNiCoO_3$ 촉매에 의한 자동차 배기중의 일산화탄소의 산화반응에 관한 연구)

  • 이근배;이석희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.57-72
    • /
    • 1990
  • The oxidation of carbon monoxide on a catalyst, $LaSrNiCoO_3$ was investigatigated with a plug flow system. Kinetic quantities such as reaction-rate, reaction order and Arhenius-parameters at various reactor temperature from 200$^\circ$C to 300$^\circ$C were determined. Also, the optimum condition for the oxidation of carbon monoxide with this catalyst was determined and are as follows. Partial pressure of oxigen ; 428mmHg Partial pressure of carbon monoxide ; 332mmHg Mixed moral ratio of oxigen and Carbon monoxide ; 1.3 : 1 Total gas flow ; 224ml/min Reaction temperature ; 340$^\circ$C The reaction kinetic equation at the optimum condition, temperature range from 200$^\circ$C to 340$^\circ$C, are as follow. $$ $v = Ae^{6.5Kcal/RT} [CO]^{0.93 \sim 0.98} [O_2]^{0.42 \sim 0.50}$ $$ In addition to this, numerical calculation were performed to evaluate the mass and heat transfer effect on this system.

  • PDF

Effects of Hyperbaric Oxygen Treatment on the Malondialdehyde Level and Oxygen Free Radical Reactions in the Heart of the Rats Exposed to Carbon Monoxide (일산화탄소 폭로후 고압산소 투여가 흰쥐 심장에서의 malondialdehyde 함량과 산소유리기 반응에 미치는 영향)

  • 신인철;고현철;하지희
    • Biomolecules & Therapeutics
    • /
    • v.6 no.1
    • /
    • pp.9-13
    • /
    • 1998
  • ln an attempt to define the effects of hyperbaric oxygen treatment on the lipid peroxidation and oxygen See radical reactions in rats exposed to carbon monoxide, we studied malondialdehyde(MDA) level and activities of catalase and superoxide dismutase in the heart of the rats exposed to carbon monoxide. Male Sprague-Dawley albino rats weighing 240 to 260gm were used. Experimental groups consist of Control group (=breathing with air), HBO group(=exposed to hyperbaric oxygen(HBO, 3ATA, 100%) after air breath), CO group(=exposed to CO(3,970 ppm) after air breath), CO-Air group(=exposed to CO after air breath followed by air breath) and CO-HBO group(=exposed to CO after ai. breath followed HBO treatment). The CO group showed significantly higher MDA level, catalase activity and SOD activity as compared to that of control group. The CO-HBO group showed significantly lower MDA level as compared to that of CO group, and did not show significantly lower catalase activity and SOD activity as compared to that of CO group. These results suggest that the excessive oxygen free radicals is an important determinant in pathogenesis of Co-induced cardiotoxicity and HBO inhibits the lipid peroxidation caused by excessive oxygen free radicals in the heart of the rats exposed to carbon monoxide.

  • PDF

Effects of Hyperbaric Oxygen Treatment on the Malondialdehyde Level and Activities of Catalase and Superoxide Dismutase in the Kidney of the Rats Exposed to Carbon Monoxide (일산화탄소 폭로후 고압산소 투여가 흰쥐 신장에서의 malondialdehyde 함량과 catalase 및 superoxide dismutase 활성에 미치는 영향)

  • 신인철;강주섭;고현철;하지희
    • Biomolecules & Therapeutics
    • /
    • v.7 no.2
    • /
    • pp.121-126
    • /
    • 1999
  • In an attempt to define the effects of hyperbaric oxygen treatment on the lipid peroxidation and oxygen free radical reactions in rats exposed to carbon monoxide, we studied malondialdehyde (MDA) level and activities of catalase and superoxide dismutase in the kidney of the rats exposed to carbon monoxide. Male Sprague-Dawley albino rats weighing 240 to 260 gm were used. Experimental groups consist of Control group (=breathing with air), HBO group (=exposed to hyperbaric oxygen 〔HBO, 3ATA, 100%〕 after air breath), CO group (=exposed to CO〔3,970 ppm〕after air breath), CO-Air group (=exposed to CO after air breath followed by air breath) and CO-HBO group (=exposed to CO after air breath followed HBO treatment). The CO group showed significantly higher MDA level, catalase activity and SOD activity as compared to that of control group. The CO-HBO group showed significantly lower MDA level as compared to that of CO group, and did not show significantly lower catalase activity and SOD activity as compared to that of CO group. These results suggest that the excessive oxygen free radicals is an important determinant in pathogenesis of CO-induced nephrotoxicity and HBO inhibits the lipid peroxidation caused by excessive oxygen free radicals in the kidney of the rats exposed to carbon monoxide.

  • PDF

Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler (가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

Revies on the Carbon Monoxide Poisoning in Korea (한국에 있어서 연탄가스 중독에 관한 역학적 조사)

  • 이옥휘
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1978
  • Carbon monoxide poisoning is one of the most serious health problems in Korea. In this review, the author made a intensive reference review on the causes of carbon monoxide poisoning, the patterns of carbon monoxide poisoning and the prospects of CO poisoning. Following findings were induced through the review. 1. Carbon monoxide poisoning is influenced by variable social factors than any other diseases or accidents and is more closely related with the economical and cultural parameters of the community. 2. The increase of risk in the populatlon is expected by National Energy Policy and the hazards of CO poisoning will rather be increasing as long as no radical control measure will be taken. 3. More practical control measure, including extensive public relation service, should be established to eradicate this serious health hazard in Korea.

  • PDF

Analysis of Tropospheric Carbon Monoxide using MOPITT data

  • Lee, Sang-Hee;Park, Gi-Hyuk;Lim, Hyo-Suk;Lee, Joo-Hee
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.373-377
    • /
    • 2002
  • The Measurement of Pollution in the Troposphere (MOPITT) instrument is an eight-channel gas correlation radiometer launched on the Earth Observing System (EOS) Terra spacecraft in 1999. Its main objectives are to measure carbon monoxide (CO) and methane (CH4) concentrations in the troposphere. This work analyzes tropospheric carbon monoxide distributions using MOPITT data in East Asia and compared ozone distributions. In general, seasonal CO variations are characterized by a spring peak and decreased in the summer. Also, this work revealed that the seasonal cycles of CO are spring maximum and summer minimum with averaged concentrations ranging from 118ppbv to 170ppbv. The CO monthly means show a similar profiles to those of O3. This fact clearly indicates that the high concentration of CO in spring is caused by two possible causes: the photochemical CO production in the troposphere, transport of the CO in the northeast Asia. The CO and O3 seasonal cycles in northeast Asia are influenced extensively by the seasonal exchange of the different types of air mass due to the Asian monsoon. The continental air masses contain high concentrations of O3 and CO due to higher continental background concentrations and sometimes due to the contribution of regional pollution. In summer the transport pattern is reversed. The Pacific marine air masses prevail over Korea, so that the marine air masses bring low concentrations of CO and O3, which tend to give the apparent minimum in summer.

  • PDF

A Method to Prevent CO Poisoning from Instantaneous Water Heaters (순간 가스온수기의 CO 중독사고 예방에 관한 연구)

  • Ahan, Jeong-Jin;Yeo, Chang-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.26-30
    • /
    • 2011
  • Instantaneous water heater being not properly installed and not adequately maintained may produce fatal accidents due to carbon monoxide poisoning and suffocation. Insufficient supply of air into the gas appliance for complete burning of the fuel or blocking the outlet of the combustion gas could be a cause to increase carbon monoxide concentration in the exhaust gas of the gas appliance. In this work, the experiments are done with a collected instantaneous water heater using in domestic and the concentration of oxygen near the gas appliance and carbon monoxide in exhaust gas are observed to investigate the risk of instantaneous water heater. The concentration of oxygen near the gas appliance is reduced until 17.7% for the ratio of the ventilation area and floor area being 3.5%. If the outlet of combustion gas is blocked, the carbon monoxide concentration is steeply increasing more than 4,000ppm. Therefore, periodic checking the outlet of combustion gas is more important than vent area to reduce the risk of carbon monoxide poisoning.

10 Cases of Hearing Loss due to CO Intoxication (급성 일산화탄소중독성 난청의 10례)

  • 김기령;김영명;김귀언;이만응
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.3.2-3
    • /
    • 1977
  • Deafness has been considered in recent publications a transient feature in the neurological complications of carbon monoxide poisoning. The inner ear is a sensitive as central nervous system to anoxia. It is well known a similar vulnerability to the toxic action of carbon monoxide for the two neurosensory epithelia of the organ of Corti. There is geographical character in the carbon monoxide poisoning and more frequently experienced in Korea. 10 cases of hearing loss due to carbon monoxide intoxication were reported with the literature review.

  • PDF

Motor Peripheral Neuropathy Involved Bilateral Lower Extremities Following Acute Carbon Monoxide Poisoning: A Case Report (급성 일산화탄소 중독 환자에서 발생한 양하지 말초 운동신경병증 1례)

  • Choi, Jae-Hyung;Lim, Hoon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.13 no.1
    • /
    • pp.46-49
    • /
    • 2015
  • Carbon monoxide (CO) intoxication is a leading cause of severe neuropsychological impairments. Peripheral nerve injury has rarely been reported. Following are brief statements describing the motor peripheral neuropathy involved bilateral lower extremities of a patient who recovered following acute carbon monoxide poisoning. After inhalation of smoke from a fire, a 60-year-old woman experienced bilateral leg weakness without edema or injury. Neurological examination showed diplegia and deep tendon areflexia in lower limbs. There was no sensory deficit in lower extremities, and no cognitive disturbances were detected. Creatine kinase was normal. Electroneuromyogram patterns were compatible with the diagnosis of bilateral axonal injury. Clinical course after normobaric oxygen and rehabilitation therapy was marked by complete recovery of neurological disorders. Peripheral neuropathy is an unusual complication of CO intoxication. Motor peripheral neuropathy involvement of bilateral lower extremities is exceptional. Various mechanisms have been implicated, including nerve compression secondary to rhabdomyolysis, nerve ischemia due to hypoxia, and direct nerve toxicity of carbon monoxide. Prognosis is commonly excellent without sequelae. Emergency physicians should understand the possible-neurologic presentations of CO intoxication and make a proper decision regarding treatment.

  • PDF