• Title/Summary/Keyword: Carbon film

Search Result 1,327, Processing Time 0.027 seconds

Effect of $CH_4$ addition to the $H_2O$ plasma excited by VHF ICP for production of $H_2$ (고주파유도결합에 의해 여기된 물플라즈마로부터 고효율 수소생산을 위한 메탄가스 첨가효과)

  • Kim, Dae-Woon;Choo, Won-Il;Jang, Soo-Ouk;Jung, Yong-Ho;Lee, Bong-Ju;Kim, Young-Ho;Lee, Seung-Heun;Kwon, Sung-Ku
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.442-442
    • /
    • 2008
  • Hydrogen was produced by water plasma excited in very high frequency inductively coupled tube reactor. Mass spectrometry was used to monitor gas phase species at various process conditions. Water dissociation rate depend on the process parameters such as ICP power, flow-rate and pressure. Water dissociation percent in ICP reactor decrease with increase of chamber pressure and $H_2O$ flow rate, while increase with increase of ICP power. In our experimental range, maximum water dissociation rate was 65.5% at the process conditions of 265 mTorr, 68 sccm, and 400 Watt. The effect of $CH_4$ addition to a water plasma on the hydrogen production has been studied in a VHF ICP reactor. With the addition of $CH_4$ gas, $H_2$ production increases to 12% until the $CH_4$ flow rate increases up to 15 sccm. But, with the flow rate of $CH_4$ more than 20 sccm, chamber wall was deposited with carbon film because of deficiency of oxygen in gas phase, hydrogen production rate decreased. The main roles of $CH_4$ gas are to reacts with O forming CO, CHO and $CO_2$ and releasing additional $H_2$ and furthermore to prevent reverse reaction for forming $H_2O$ from $H_2$ and $O_2$. But, $CH_4$ addition has negative effects such as cost increase and $CO_x$ emission, therefore process optimization is required.

  • PDF

Prediction Model of Remaining Service Life of Concrete for Irrigation Structures by Measuring Carbonation (중성화 측정을 통한 콘크리트의 잔존수명 예측 모델)

  • Lee, Joon-Gu;Park, Kwang-Soo;Kim, Han-Joung;Lee, Joung-Jae
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.529-540
    • /
    • 2003
  • Recently, the researches on the durability design of concrete structures have been studied. As the examples, models to evaluate the service life prediction of the structure have been developed. The purpose of this article is to develop the model for predicting remaining service life. The final aim is to provide the user time for repairing the concrete structures. In addition, it makes possible to maintain the concrete structure economically. 70 reservoirs out of the inland concrete structures were selected and concrete structures of their components were surveyed. Two methods were used for measuring carbonation; TG/DTA method and Phenolphtalein indicator and, the value of pH was measured by the pH meter, After deriving correlations of calcium carbonate and used year, duration from completion year to 2002, pH value, and concrete cover depth the model was developed for predicting remaining service life by measuring data as small as possible. The conventional models had been developed on the basis of experiment data obtained from the restricted lab environment like as carbon gas exposure. On the other hand this model was developed on the basis of measuring data obtained from the real field that the complex deterioration actions are occurred such as freezing and thawing, carbonation, steel corrosion, and so on. The reliability of the developed model will be evaluated high in this point and this model can help to maintain concrete structures economically by providing the manager time to repair the deteriorated concrete structures in site of facility management.

Interfacial Control of Multi-functional CNT and ITO/PET Nanocomposites having Self-Sensing and Transparency (자체-감지능 및 광투과도를 지닌 CNT 및 ITO/PET 다기능성 나노복합소재의 계면 조절 연구)

  • Wang, Zuo-Jia;Kwon, Dong-Jun;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Transparent and conductive carbon nanotube on polyethylene terephthalate (PET) were prepared by dip-coating method for self-sensing multi-functional nanocomposites. The changes in the electrical and optical properties of CNT coating mainly depended on the number of dip-coating, concentration of CNT solution. Consequently, the surface resistance and transmittance of CNT coating were sensitively controlled by the processing parameters. Surface resistance of CNT coating was measured using four-point method, and surface resistance of coated CNT could be better calculated by using the dual configuration method. Optical transmittance of PET film with CNT coating was evaluated using UV spectrum. Surface properties of coated CNT investigated by wettability test via static and dynamic contact angle measurement were consistent with each other. As dip-coating number increased, surface resistance of coated CNT decreased seriously, whereas the transmittance exhibited little lower due to the thicker CNT networks layer. Interfacial microfailure properties were investigated for CNT and indium tin oxide (ITO) coatings on PET substrates by electrical resistance measurement under cyclic loading fatigue test. CNT with high aspect ratio exhibited no change in surface resistance up to 2000 cyclic loading, whereas ITO with brittle nature showed a linear increase of surface resistance up to 1000 cyclic loading and then exhibited the level-off due to reduced electrical contact points based on occurrence of many micro-cracks.

A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE THICKNESS OF TOOTH STRUCTURE PENETRATED BY LIGHT AND APPLIED LIGHT CURING TIME (조사광이 통과하는 치질의 두께와 광조사시간에 따른 광중합형 복합레진의 중합률에 관한 연구)

  • Hwang, Kee-Hwan;Jang, In-Ho;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.16-23
    • /
    • 2002
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc depend on the degree of conversion of the resin components. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the thickness of tooth structure penetrated by light and applied light curing time. The coronal portions of extracted human teeth (one anterior tooth, three posterior tooth) was embedded by pink denture material. the mounted teeth were cut into three illumination sections (1mm thickness enamel section, 1mm thickness dentin section, 2mm thicknes dentin section) and one backing section with cutting wheel. Thin resin films were made by using 6kg pressure between slide glass during 5 minutes Thin resin film was light cured on coupled illumination section during 40sec, 80sec and 120sec. each illumination section was coupled as follows; no tooth structure(X), ename section(E), enamel section + 1mm dentin section(ED1), enamel section + 2mm dentin section(ED2), enamel section + 1mm dentin section + 2mm dentin section(EDD). To simulate the clinical situation more closely, thin resin films was cured against a backing section of tooth structure. The degree of conversion of carbon double bonds to single bonds in the resin films were examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows ; 1 As curing time was increased, conversion rate was increased and as tooth thickness which was penetrated by curing light was increased, conversion rate was decreased. 2. At all tooth thickness groups, conversion rate between 80sec and 120sec was not significantly increased(P>0.05). 3. At 40sec group and 80sec, conversion rate between no tooth structure(X) group and 1mm enamel section(E) group was not significantly decreased(P>0.05). 4. At 80sec group and 120sec, conversion rate between 1mm enamel section(E) group and 1mm enamel section + 1mm dentin section(ED1) group was not significantly decreased(P>0.05).

Effect of postharvest CO2 treatment on the quality of the 'Gonji-7ho' oyster mushroom (Pleurotus ostreatus) during oriented polypropylene packaging and storage (수확 후 CO2처리가 느타리버섯 곤지7호의 OPP 포장 저장 중 품질에 미치는 영향)

  • Choi, Ji-Weon;Lee, Ji-Hyun;Kim, Chang-Kug;Shin, Il-Sub;Bae, Yeoung-Seuk
    • Journal of Mushroom
    • /
    • v.18 no.1
    • /
    • pp.115-119
    • /
    • 2020
  • This study was conducted to investigate the effect of post-harvest CO2 treatment on the quality of the 'Gonji-7ho' oyster mushroom. The harvested mushrooms were pre-cooled at 3℃ for 1 day and placed in a gas-tight chamber with 0%, 30%, or 50% of CO2 concentration for 3 hours at 3℃. Next, 400 g of the oyster mushroom sample was packaged into 20-㎛ thick oriented polypropylene (OPP) film bags and stored at 4℃ for 21 days. Treatment with 30% of CO2 treatment maintained the highest stipe firmness of the oyster mushrooms during storage. The stipe lightness (CIE L) was the highest at 14 and 21 days, while the stipe yellowness (CIE b) was the lowest at 2 and 7 days of storage. Therefore, we concluded that the 30% CO2 treatment maintained the overall visual quality of the 'Gonji-7ho' oyster mushroom until 17 days of storage at 3℃. Our results suggest that the shelf life of 'Gonji-7ho' oyster mushroom could be extended by the postharvest application of 30% CO2 for 3 hours during low temperature storage.

A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME (수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구)

  • Kim, Kyung-Hyun;Kwon, Oh-Sung;Kim, Hyun-Gee;Baek, Kyu-Chul;Um, Chung-Moon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

$NO_{2}$ Sensing Properties of Oxide Semiconductor Thick Films (산화물 반도체형 후막 가스 센서의 이산화질소 감지 특성)

  • Kim, Seung-Ryeol;Yun, Dong Hyun;Hong, Hyung-Ki;Kwon, Chul-Han;Lee, Kyu-Chung
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.451-457
    • /
    • 1997
  • The thick films of oxide semiconductors such as $WO_{3}$, $SnO_{2}$ and ZnO for the $NO_{2}$ detection of sub-ppm range have been prepared and their characteristics were investigated. It is showed that the optimum operating temperatures of the sensors are $300^{\circ}C$ and $220{\sim}260^{\circ}C$ for $WO_{3}$-based and $SnO_{2}$-based thick films, and ZnO-based thick films, respectively. Since the resistance of ZnO-based thick films are extremely high($>10^{6}{\Omega}$), the signal to noise ratio was comparatively low. In order to determine the selectivity, the films are exposed to the interfering gases such as ozone, ammonia, methane and the mixture of carbon monoxide and propane. $WO_{3}$-ZnO(3 wt.%) and $SnO_{2}-WO_{3}$(3 wt.%) thick film sensors show high sensitivity, good selectivity, excellent reproducibility and the linearity of $NO_{2}$ concentration versus sensor resistance. The preliminary results clearly demonstrated that the sensor can be successfully applied for the detection of $NO_{2}$ in sub-ppm range.

  • PDF

Fabrication and Characterization of Portable Electronic Nose System for Identification of CO/HC Gases (CO/HC 가스 인식을 위한 소형 전자코 시스템의 제작 및 특성)

  • Hong, Hyung-Ki;Kwon, Chul-Han;Yun, Dong-Hyun;Kim, Seung-Ryeol;Lee, Kyu-Chung;Kim, In-Soo;Sung, Yung-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.476-482
    • /
    • 1997
  • A portable electronic nose system has been fabricated and characterized using an oxide semiconductor gas sensor array and pattern recognition techniques such as principal component analysis and back-propagation artificial neural network. The sensor array consists of six thick-film gas sensors whose sensing layers are Pd-doped $WO_{3}$, Pt-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$ + Pd coated layer, $Al_{2}O_{3}$-doped ZnO and $PdCl_{2}$-doped $SnO_{2}$. The portable electronic nose system consists of an 16bit Intel 80c196kc as CPU, an EPROM for storing system main program, an EEPROM for containing optimized connection weights of artificial neural network, an LCD for displaying gas concentrations. As an application the system has been used to identify 26 carbon monoxide/hydrocarbon (CO/HC) car exhausting gases in the concentration range of CO 0%/HC 0 ppm to CO 7.6%/HC 400 ppm and the identification has been successfully demonstrated.

  • PDF

Objective Aperture Effects for the Quantitative Analysis in Electron Tomography (전자토모그래피의 정량적 분석에서 대물렌즈 조리개의 영향)

  • Kim, Jin-Gyu;Lee, Sang-Hee;Kweon, Hee-Seok;Jeong, Jong-Man;Jeong, Won-Gu;Lee, Su-Jeong;Jou, Hyeong-Tae;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • We have evaluated the effects of experimental factors on transmitted electron beam intensities for quantitative analysis in electron tomography. For the correct application of Beer's law in electron tomography, the transmitted beam intensity should reflect the net effect of mass properties on beam path. So, the any other effects of the objective aperture and the specimen holder on beam path should be removed. The cut-off effects of objective aperture were examined using Quanti-foil holey carbon film and a transmission electron microscope operated at 120 kV. The transmitted beam intensities with $30{\mu}m$ objective aperture dropped about 16.7% compared to electron beam intensities without the objective aperture. Also, the additional losses of about 14.2% at high tilt angles were occurred by cut-off effects of the objective apertures. For the precise quantitative analysis in electron tomography, the effect of the objective aperture on transmitted electron beam intensities should be considered. It is desirable that 2-D tilt series images are obtained without the objective aperture for correct application of Bee's law.

Current Research Status of Postharvest and Packaging Technology of Oriental Melon (Cucumis melo var. makuwa) in Korea (국내 참외의 수확 후 관리 및 포장기술 연구)

  • Kim, Jung-Soo;Choi, Hong-Ryul;Chung, Dae-Sung;Lee, Youn-Suk
    • Horticultural Science & Technology
    • /
    • v.28 no.5
    • /
    • pp.902-911
    • /
    • 2010
  • Oriental melon ($Cucumis$ $melo$ var. $makuwa$) is a popular and high-value market fruit cultivated in Korea. Consumers are becoming increasingly interested in oriental melon as a healthy diet over the past few years. However, the melons have relatively high quality loss because the fruit are mainly produced for a limited period of time in the summer season. Lack of the proper postharvest treatments and high temperature exposure at harvest or during distribution are the most critical environmental factors limiting postharvest life of fruit. This review focuses on the overview of current research studies for postharvest treatment and functional packaging technology of oriental melon in Korea. Major physiological problems of the harvest fruit include the ripening process in quality changes of the produce such as loss of weight, firmness, flavor, and decay during the storage periods. Low temperature at 7 to $10^{\circ}C$ with high relative humidity of 90 to 95% is the suitable environmental condition used to maintain the quality of fresh oriental melon. Controlled atmosphere (CA) storage or modified atmosphere (MA) packaging can be used as supplemental treatments to extend postharvest-life. For oriental melon, an optimum CA is currently recommended to be 2-3% oxygen and 5-10% carbon dioxide atmosphere. Precooling, pretreatments of ethylene action and functional packaging system can be applied to oriental melon after harvest in order to extend storage life. Major active packaging technologies are concerned with a selectively gas permeable film related to respiration of produce and the packaging applications of ethylene removal, antimicrobial, and antifogging substances to keep the effective freshness of fruit.