• 제목/요약/키워드: Carbon fiber reinforced plastic plate

검색결과 40건 처리시간 0.029초

CFRP 플레이트로 휨보강한 보의 거동에 대한 비선형 FEM 해석 (Non-Linear FEM Analysis Study of the Flexural Behavior of the RC Beams Strengthened by CFRP plate)

  • 고병순;양동석;박선규;유영찬;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.536-539
    • /
    • 2004
  • This paper focues on the flexural behavior of RC beams externally reinforced using Carbon Fiber Reinforced Plastics plates. (CFRP) A non-linear finite element (FE) analysis is proposed in order to complete the experimental analysis of the flexural behaviour of the beams. This paper is a part of a complete program aiming to set up design formulate to predict the strength of CFRP strengthende beams, particularly when premature failure through plates-end shear or concrete cover delamination occurs. An elasto-plastic behaviour is assumed for reinforced concrete and interface elements are used to model the bond and slip.

  • PDF

CFRP 적층판으로 보강된 철근콘크리트보의 신뢰성평가 (Reliability Assessment of Reinforced Concrete Beams Strengthened by CFRP Laminates)

  • 조효남;최영민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.160-166
    • /
    • 1994
  • In general, the problems of strengthening and repairing of deteriorated or damaged reinforced concrete members are usually worked out in situ by externally bounding steel plates using epoxy resins, which has been recognized to be one of effective and convenient methods. But the disadvantages of strengthening/repairing concrete members with externally bonded steel plates include ; (a) deterioration of the bond at the steel-concrete interface caused by the corrosion of steel ; (b) difficulty in manipulating the plate at the construction site ; (c) improper formation of joints, due to the limited delivery lengths of the steel plates ; and etc. Therefore these difficulties eventually have led to the concept of replacing the steel plates by fiber-reinforced composite sheets which are characterized by their light weight, extremely high stiffness, excellent fatigue properties, and outstanding corrosion resistance. In the paper, for the reliability assessment of reinforced concrete beams externally strengthened by carbon fiber plastic(CFRP) laminates, an attempt is made to suggest a limit state model based on the strain compatibility method and the concept of fracture mechanics. And the reliability of the proposed models is evaluated by using the AFOSM method. The load carrying capacity of the deteriorated and/or damaged RC beams is considerably increased. Thus, it may be stated that the post-strengthening of concrete beams with externally bonded CFRP materials may be one of very effective way of increasing the load carrying capacity and stiffeness characteristics of existing structures.

  • PDF

적층각도에 따른 CFRP 평판에서의 굽힘으로 발생한 크랙 파손에 관한 해석적 연구 (Analysis Study on the Damage of Crack Happening with the Bending at CFRP Plate due to Stacking Angle)

  • 황규완;조재웅
    • 한국융합학회논문지
    • /
    • 제8권3호
    • /
    • pp.185-190
    • /
    • 2017
  • 본 논문은 탄소섬유로 구성된 평판형태의 시험편에 굽힘 모멘트가 작용할 때 내부의 섬유구조에서 발생되는 굽힘 응력과 전단응력, 변형에너지에 관한 것이다. CFRP는 무수히 많은 섬유가 다축구조를 형성하고 있어 굽힘조건에서 응력을 효과적으로 분산할 수 있다. 이때 적층각도에 따라 다양한 물성을 보이게 되는데, 섬유의 수평방향인 Stacking angle $0^{\circ}$에서부터 수직방향인 $90^{\circ}$에 이르기까지의 결과에 있어, Stacking angle이 증가함에 따라 등가 응력과 전단응력이 점차 줄어들며 $60^{\circ}$를 기점으로 다시 증가함을 보이고 있다. 본 연구결과를 토대로,적층각도에 따른 평판에서의 굽힘으로 인한 파손특성을 해석적 접근을 통해 고찰하였으며, 본연구는 파손방지와 내구성 향상을 위한 안전설계에 기여할 수 있다고 사료된다. 또한 평판 형상으로서의 디자인적 요소를 융합기술에 접목함으로서 그 미적인 감각을 나타낼 수 있다.

Analysis of Time-Dependent Deformation of CFRP Considering the Anisotropy of Moisture Diffusion

  • Arao, Yoshihiko;Koyanagi, Jun;Hatta, Hiroshi;Kawada, Hiroyuki
    • Advanced Composite Materials
    • /
    • 제17권4호
    • /
    • pp.359-372
    • /
    • 2008
  • The moisture absorption behavior of carbon fiber-reinforced plastic (CFRP) and its effect on dimensional stability were examined. Moisture diffusivity in CFRP was determined by measuring a specimen's weight during the moisture absorption test. Three types of CFRP specimens were prepared: a unidirectionally reinforced laminate, a quasi-isotropic laminate and woven fabric. Each CFRP was processed into two geometries - a thin plate for determination of diffusivity and a rod with a square cross-section for the discussion of two-dimensional diffusion behavior. By solving Fick's law expanded to 3 dimensions, the diffusivities in the three orthogonal directions were obtained and analyzed in terms of the anisotropy of CFRP moisture diffusion. Coefficients of moisture expansion (CMEs) were also obtained from specimen deformation caused by moisture absorption. During moisture absorption, the specimen surfaces showed larger deformation near the edges due to the distribution of moisture contents. This deformation was reasonably predicted by the finite element analysis using experimentally determined diffusivities and CMEs. For unidirectional CFRP, the effect of the fiber alignment on CME was analyzed by micromechanical finite element analysis (FEA) and discussed.

Flexural Characteristics of the Overlayed RC Beam Strengthened with Rebars, CFRP, and Steel Plate.

  • 오홍섭;심종성;이차돈;최완철;신영수;홍기섭;홍영균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.221-229
    • /
    • 1996
  • An analytical method based on the nonlinear layered finite element method is used to simulate the load-deflection behavior of strengthened beam. Beams considered in this study are the ones strengthened either with external steel plate or Carbon Fiber Reinforced Plastic (CFRP) sheets bonded to the overlay soffit or with reinforcing rebars in the overlay. The theoretically obtained load-deflections and strains of the strengthened beam are compared to the corresponding experimental values. Comparing the approximate measures on the cumulative slips, efficiencies of the repairing techniques are evaluated. Parametric studies are, then, peformed using the developed model to investigate the effects of design variables on the overal flexural behavior of the strengthened beam. Simply supported beams under monotonically increasing symmetrical loads are considered exclusively.

  • PDF

탄소섬유판으로 보강된 철근콘크리트 보의 보강성능에 관한 연구 (A Study on Structural Performance Evaluation of RC Beams Strengthened with CFRP Plate)

  • 김중구
    • 한국건설관리학회논문집
    • /
    • 제5권6호
    • /
    • pp.212-217
    • /
    • 2004
  • 이 연구는 같은 위치에 힘모멘트와 전단력이 최대가 되는 철근콘크리트 보에 대하여 휨모멘트 보강을 실시하는 경우, 탄소 섬유판의 두께와 하중점 부위 및 탄소섬유판의 끝부분을 감싸는 탄소섬유쉬트의 겹수를 변수로 하여 보의 구조적 거동을 실험하였다. 탄소섬유판의 두께의 증가에 따라 내력이 증가하였으나 선형적으로 비례하지 않았으며, 하중점에 감싼 탄소섬유쉬트의 영향은 뚜렷하게 나타나지 않았다 이 는 보강시험의 주된 파괴가 탄소섬유판의 파단이 아닌 하중점 주위에서의 휭-전단균열에서부터 층분리가 시작되었고 하중점을 탄소섬유쉬트로 감싼 경우 휭-전단균열 탄소섬유쉬트의 바깥 부분으로 이동하기 때문이다. 또한 탄소섬유판 단부에 정착용으로 시공한 탄소섬유쉬트는 하중점에서 발생한 취성파괴로 인하여 큰 효과를 나타내지 못하였다. 그러므로 재하상태에 따른 설계방법을 다르게 할 필요가 있으며, 특히 같은 위치에서 휨모멘트와 전단력이 최대가 되는 경우 탄소섬유판의 유효 두께는 최대 0.6mm로 하고 무보강보의 휨모멘트에 대한 보강된 보의 휨모멘트 비는 1.5-2.0으로 제한하는 것이 바람직하며, 0.6mm이상의 탄소섬유판을 사용하기 위하여 탄소섬유쉬트로 하중점을 보강하는 경우 무보강보 휨모멘트의 1.5 배가 되는 위치이상 탄소섬유쉬트를 연장하는 것이 바람직하다.

탄소복합재 부품 파티션패널의 구조 강성/강도 신뢰성 평가에 관한 연구 (Study on Structural Reliability Assessment of a Partition Panel Made of a CFRP(Carbon Fiber Reinforced Plastic))

  • 이재진;문지훈;윤원호;강다경;안민수;노형진;강지헌;이재욱
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.68-74
    • /
    • 2019
  • In the case of a partition panel for a vehicle, it is used as a vehicle chassis component that serves to distinguish the indoor and outdoor spaces of a vehicle and is mounted on a backrest portion of the vehicle's back seat to ensure the convenience of passengers by connecting the floor and the side of the vehicle. Because it is a relatively large-sized plate material among automobile chassis parts except the moving parts and non-ferrous materials can be applied, it is considered as a part having a large light-weight effect. However, the partition panel is one of the vehicle parts that must satisfy the light-weight effect as well as various structural reliability, such as torsional rigidity, vibration, and impact characteristics, for securing the running stability of the vehicle when driving at the same time. So, In this study, the possibility of replacing the aluminum partition panel as CFRP(Carbon Fiber Reinforced Plastic) partition panel is evaluated through comparing the two partition panels by using the structural reliability(stiffness/strength analysis), vibration analysis, impact analysis.

피로하중에 의한 홀 노치 탄소섬유강화 복합재의 잔류강도변화 평가 (Evaluation of Variation in Residual Strength of Carbon Fiber Reinforced Plastic Plate with a Hole Subjected to Fatigue Load)

  • 김상영;강민성;구재민;석창성
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1411-1417
    • /
    • 2010
  • 탄소섬유강화 복합재료는 높은 비강도, 비강성, 설계유연성 및 우수한 화학적 특성 등으로 인하여 여러분야에서 각광받고 있는 구조재료이다. 대부분의 CFRP 복합재료 제품들은 여러 부품들을 주로 볼트, 핀 등의 기계적인 방법으로 조립하여 제작된다. 볼트나 핀에 의해 발생하는 hole 은 구조물 내에서 노치로 작용하여 부품의 강도저하의 원인으로 작용한다. 본 논문에서는 피로하중에 의한 CFRP 복합재료 홀 노치재의 잔류강도를 실험적으로 평가하였다. 이를 위하여, 시편에 일정 반복 수만큼 피로하중을 부여하였으며, 이후 파괴시험을 통하여 홀 노치재의 잔류강도를 측정하였다. 그 결과, 피로하중으로 인해 하중방향의 균열이 발생하는 것을 확인하였으며 이 균열이 홀의 노치효과를 감소시켜 잔류강도를 증가시키는 것으로 생각되었다. 시편의 잔류강도는 일정 수준까지 증가하다가 감소하는 것으로 평가되었으며, 이를 Reifsneider 등의 평활재 잔류강도 저하모델과 Yip 등의 홀 노치재 응력재분포 함수를 이용하여, 피로하중 하의 홀 노치재 잔류강도 변화를 수식으로 나타내었다.

대형 CFRP Plate용 정착구의 설계요소분석 및 최적설계 (An Analysis of Design Parameters and Optimal Design for Anchors with Wide CFRP Plate)

  • 김형준;정흥진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.102-112
    • /
    • 2020
  • 본 연구에서는 교량구조물에 활용할 수 있는 폭 100mm 이상의 대형 탄소판을 고정할 수 있는 쐐기형 정착구를 설계하기 위해서, 주요설계변수인 쐐기의 각도, 정착블록-쐐기 사이의 마찰계수 등을 기준으로 거동특성을 수치해석방법으로 분석하였다. 설계변수 별로 탄소판의 응력상태를 계산하고, 복합재료 파괴기준에 의하여 정착구의 극한상태에서의 성능을 평가하였고, 이를 바탕으로 정착구의 최적설계 제원을 결정하였다. 실물실험을 통하여 최적설계된 정착구의 성능을 검증하였으며, 본 연구의 결과는 대형 구조물을 보강하기 위한 탄소판 정착구의 최적설계에 활용될 수 있을 것으로 판단된다.

비틀림을 받는 중앙부에 노치홀을 가진 CFRP 판의 구조 안전성에 관한 연구 (A Study on Structural Safety of CFRP Plate with Notch Hole at Center Part under Torsion)

  • 김재원;조재웅
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제7권11호
    • /
    • pp.925-932
    • /
    • 2017
  • 본 연구에서는 복합재료들 중 단방향성 탄소섬유강화플라스틱(UD CFRP)에서의 적층각도에 따른 비틀림을 받는 판의 해석을 수행하였다. UD CFRP의 경우에는 적층각도에 따른 물성치가 달라진다. 그리고 연구 모델들에서 탄소 섬유의 적층각도는 15°, 30°, 45°, 60°, 75°, 90° 로 지정하였다. 중앙부에는 리벳이나 볼트가 사용될 것으로 가정하여 노치홀을 적용하였다. ISO 15310에서의 실험 방식을 적용하여 해석 방법을 사용했다. 하부에서 2개의 지그를 고정하고 상부에서 2개의 지그를 하강한다. 본 연구에서의 해석 결과값을 보았을 때, 적층각도가 45°일 경우가 파단 부위에 나타나는 전단응력이 254.74MPa로 가장 작은 값으로 나타남을 보였다. 따라서 비틀림이 작용할 때, 45°의 적층각도의 경우가 다른 적층각도에 비하여 더 높은 구조안전성과 내구성을 가졌음을 알 수 있었다. 이러한 결과는 CFRP 판에 비틀림이 작용할 때 그 내구성에 기여할 수 있는 기반 데이터로 적용될 수 있다고 사료된다.