• Title/Summary/Keyword: Carbon Heating Source

Search Result 70, Processing Time 0.025 seconds

Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature (고온 카본발열체의 발열특성에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Shin, J.H.;Jeong, H.M.;Chung, H.S.;Chun, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF

A Study on Application of Warm Air Circulator by Using the Carbon Heating Element with Particle Type (입상 탄소 발열체의 열원을 이용한 온풍기의 적용에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Kong, T.W.;Chung, H.S.;Jeong, H.Y.;Chung, H.T.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.31-37
    • /
    • 2003
  • This paper is a study on application of warm air circulator by using the carbon heating element with particle type. The main variables are the input current and amount of carbon heating source for experimental characteristics. The experimental results are obtained as follows. As the input current and temperature are increased, the resistance of heat source is decreased about $20{\sim}25%$ by the effect of negative resistance. As the amount of heating source is small, Joule heat is large with the input current. When the amount of heating source is 300 and the input current is 15A, the value of Joule heat is about 4604.6kJ/h. The heat production efficiency of carbon heating source is larger about 10% than the sheath heater.

  • PDF

Numerical Analysis in Unsteady State on variation of Diameter and Environmental Velocity of Carbon Heating Source (탄소발열체의 외부유속 및 직경변화에 대한 비정상상태에서의 수치해석적 연구)

  • Bae, K.Y.;Lee, Y.H.;Lee, S.Y.;Lee, C.S.;Kim, B.G.;Lee, S.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.25-30
    • /
    • 2006
  • This paper represents the numerical analysis in unsteady state on the variation of diameter and environmental velocity of carbon heating source. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, the carbon heating source was studied through numerical analysis on several conditions of unsteady state, heat generation, diameter and environmental velocity. The temperature distributions at steady state are appeared as a non-proportional linear pattern with variations of environmental velocity due to the Nesselt number with convective heat flux is proportioned to 0.805 of Reynolds number. As the radius is increasing, the temperature distributions is appeared the minus tilt because of the environmental condition is cooling by constant temperature. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

A Study on the Application of District Heating System using Sewage Source (하수열원을 이용한 지역난방 적용성 검토)

  • Kim, Sang-Hun;Kim, Dong-Jin;Choi, Dong-Kyoo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.928-933
    • /
    • 2009
  • The purpose of this study is to examine the energy consumption, carbon dioxide emission & energy cost of district heating using sewage source. The annual TOE of heat pump using sewage source save 37.1 percent than city gas boiler. And annual carbon dioxide emission of heat pump cut down 41.3 percent than city gas boiler. If it charges the rate schedule for district heating to apartment resident, collected amount are 3,127,170 thousand won. As energy cost of heat pump & circulation pump are 1,378,072 thousand won. the profits are 1,749,098 thousand won. As payback period is 8.97years, applicability is low level. However, it has advantages in energy consumption, carbon dioxide emission & energy cost. Therefore, it needs to proceed through government assistance.

  • PDF

Numerical Analysis on Effect of the Environmental Velocity for Circular Heating Source with Heat Generation (열생성을 가진 원형발열체의 외부 유속의 영향에 대한 수치해석)

  • Bae, K.Y.;Ji, M.K.;Chung, H.S.;Chung, H.T.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • This paper represents the numerical analysis on effect of the environmental velocity for circular heating source with heat generation. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, a circular heating source was studied through numerical analysis on several conditions of unsteady state, beat generation and environmental velocity. The temperature distributions at steady state is appeared as a non-linear pattern with variations of environmental velocity. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

Preparation and Characterization of Carbon Nanofiber from Liquid Phase Carbon Source (액상법에 의한 Carbon Nanofiber 제조 및 특성 분석)

  • Lee, Won-Woo;Shin, Chae-Ho;Park, Han-Sung;Choi, Young-Min;Ryu, Beyong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.18 no.10
    • /
    • pp.564-570
    • /
    • 2008
  • Nanostructured carbon materials have been found to have applications in fuel cell electrodes, field emitters, electronic devices, sensors and electromagnetic absorbers, etc. Especially, the CNF (carbon nanofiber) can be expected to play an important role in catalyst supporters for fuel cell electrodes and chemical reactions. In this study, we synthesized CNF from a liquid phase carbon source by a solvothermal method. In addition, we studied the parameters for the preparation of CNF by controlling heating and cooling rates, synthesis temperature and time. We characterized the CNF by SEM/TEM, XRD, Raman spectroscopy and EDS. We found that the heating and cooling rate have strong effects on the CNF formation and growth. We were able to prepare the best CNF at the heating rate of $10^{\circ}$/min, at $450^{\circ}$ for 60 minutes, and at the cooling rate of $4^{\circ}$/min. As a result of Raman spectra, we found that the sample showed two characteristic Raman bands at ${\sim}1350cm^{-1}$ (D band) and ${\sim}1600cm^{-1}$ (G band). The G band indicates the original graphite feature, but the D band has been explained as a disorder feature of the carbon structure. The diameter and length of the CNF was about $15{\sim}20nm$, and over $1{\mu}$, respectively.

Development of the Dryer with a Heat Source of Carbon Nanofibers (탄소나노섬유를 열원으로 적용한 세탁물 건조기의 개발)

  • Lee, Jung-Hwan;Won, Sang-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.25-34
    • /
    • 2018
  • This paper presents a heating source of carbon nanofibers for the efficiency and the drying performance of laundry dryer, and focuses on the applicability-evaluation of its source. To design the proposed heating module, experiments were conducted in terms of surface temperature and surface temperature distribution characteristics of carbon nanofiber lamps. The surface temperature of the lamps increased linearly with increment of a current to flow a lamp and revealing the increasing pattern as the length of the ramps is shorter. The proposed heating source was evaluated based on drying efficiency, moisture evaporation rate at laundry, and internal temperature of a drum during drying process. The drying efficiency satisfied a 45% which is specified in KS C 9319. The moisture evaporation rate and the internal temperature of the drum were respectively 98.88% and $61.1^{\circ}C$, which are similar to that of S's company dryer. From the evaluation and actual drying test results, the proposed carbon nanofiber lamp heating module is considered to be applicable as a heat source for laundry dryer in terms of drying efficiency and drying performance. it is possible to obtain a heat source at a high temperature, an excellent calorific value, an improvement in drying performance, and an effect of sterilizing laundry due to the emission of far-infrared rays. In addition to the applicability, the difference of the drying efficiency between the dryers was analyzed in detail based on the power consumption of the heat sources.

Bonding Behavior of Carbon Black/Nylon 66 Hybrid Nanofiber Webs via Microwave Heating (카본블랙/나일론 66 혼합 나노섬유웹의 마이크로파에 의한 접착거동)

  • Shin, Dong-Ho;Joo, Chang-Whan
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.114-117
    • /
    • 2003
  • Conventional heating the heat source cause the molecules to react from the surface toward the center so that successive layers of molecules heat in turn. The product surfaces may be in danger of over heating by the time heat penetrates the material. Microwave, however, produce a volume heating effect. All molecules are set in action at the same time. It also evens temperature gradients and offers other important benefits such as selective heating. (omitted)

  • PDF

Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings (공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가)

  • Junseok Kim;Jongsoo Kim;Yongseok Jeon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.2
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

Vulcanization Efficiency of Non-polar Rubber Compounds by Microwave (마이크로파를 이용한 비극성 고무컴파운드의 가황 효율)

  • Jung, U-Sun;Lee, Won-Ki;Lim, Kwon-Tack
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.228-231
    • /
    • 2011
  • The rate of vulcanization of nonpolar ethylene-propylene-diene terpolymer(EPDM)/carbon black compounds was investigated by using hot air and microwave as a heating source. The present study parameters such as heating source, sample thickness, and loading of an additive. The compound thickness was the main factor in the hot air vulcanization. It was due to the poor thermal conductivity of EPDM; that is, the thicker thickness, the lower vulcanization rate. For 100% vulcanization, the compound with 3 mm thickness required 7 min at $250^{\circ}C$ in the hot air system. However, the vulcanization of EPDM compounds by microwave system was not affected by the thickness while strongly dependent on the amount of a polar additive, carbon black. A compound with 80 phr of carbon black was perfectly vulcanized within 30 sec. These results suggest that the use of microwave as a heating source is an effective method for the vulcanization of compounds including a polar component.