An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • Kim, Byeong Ju;So, Hyeon Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

A Study on the Analysis of Pesticide Residue in Banana by GC/MSD (GC/MSD를 이용한 바나나 중에서의 잔류농약 분석법에 관한 연구)

  • 박성수;김동원
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.2
    • /
    • pp.217-222
    • /
    • 1996
  • We studied about analyzing carbamate pesticides, organochlorine, organophosphorus pesticides simultaneously using by GC/MSD. For this, instead of HPLC which is generally used in analyzing carbamate pesticides, GC was used and all hydrogen of -NH group in carbamate pesticides were substituted for trifluoroacetyl group which is stable at heat And eight pesticide resdidues were not detected in nine samples circulated in the city.

  • PDF

Development of Multi-Residue Methods for Carbamate Pesticides by the Enzyme Inhibition Test (효소 저해법을 이용한 Carbamate계 농약의 다성분 잔류분석법 개발)

  • Kim, Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1325-1330
    • /
    • 2008
  • This study was carried out with the detection for multiresidue of the carbamate pesticide such as carbaryl and cabofuran by enzyme-inhibition method. The check time for determination of acetylcholinesterase(AChE) activity was selected at 60 sec. The AChE activity in chicken brain determined by the Ellman's method was $162{\mu}$mol/min/g protein. $I_{50}$ for AChE by carbamate pesticide with wet kit was 0.169mg/L of carbaryl and 0.089mg/L of cabofuran, respectively. The incubation time for enzyme kit with substrate kit was 30min for determination of AChE activity. Enzyme kit with substrate kit was stable at $4^{\circ}C\;and\;25^{\circ}C$ for 5 days. Limit detection concentration of carbaryl with dry kit for AChE was 0.05mg/L. The dry kit such as wet kit applied Enzyme-Inhibition(EI) method with AChE was confirmed the multi residue method to detect the carbamate pesticides.

A study on simultaneous determination of carbamate pesticides by HPLC (HPLC를 이용한 carbamate계 농약의 다성분 동시분석)

  • Song, Young-Gak;Seo, Young-Chul;Hyun, Gong-Yul;Cho, Woo-Young;Lee, Jong-In
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.2
    • /
    • pp.145-149
    • /
    • 2003
  • To explore the most sensitive and useful method for simultaneous determination of 8 carbamate pesticides in livestock productions, the mixture of 8 carbonates was determined by HPLC with scanning fluorescence detector. For mobile phase water, acetonitrile and methanol program gradient showed more applicable sensitivity than water and acetonitrile program gradient used ExW 339 nm and EmW 445 nm for fluorescence detector. On using carbamate columns, the retention time was within 4 to 20 minutes. And this made it possible to separate and detect simultaneously. therefore we could analyze it exactly and efficiently and reduce time. The preparation process of MSPD method showed that the high recovery rate was more than 88.5% in most of the carbamate pesticides. Therefore we could say that it was an efficient and fast method analyzing out of lots of samples.

Confirmation of carbamate pesticides by liquid chromatography coupled with electrospray ionization mass spectrometry (LC/MS를 이용한 카바메이트계 잔류농약 확인방법)

  • 박준조;금모래;고광춘;박병옥;이성식
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2002
  • A method was developed to separate, detect and qualify aldicarb, bendiocarb, carbaryl, carbofuran, ethiofencarb, methomyl, methiocarb, propoxur in meats and fruits. Experimental beef and fork samples were fortified with 0.05mg/kg of carbamate pesticides for analysis. Carbamate-detected pear by HPLC fluorescence detector(HPLC/FLS) are extracted with acetonitril and refined by solid phase extraction(SPE) filled with aminopropyl-bonded silca, In the following step, the injected materials into LC/MS are analyzed to result in the fact that bendiocarb, carbaryl, carbofuran, ethiofencarb, methomyl, methiocarb, propoxur presents several sorts of fraction ions following with; [M+H]$^{+}$, [M+Na]$^{+}$,[M-CONH$CH_3$]$^{+}$, [M-OCONH$CH_3$]$^{+}$. In addition, ethiofencarb presents [M-SCH$_2$$CH_3$]$^{+}$ ion distinctive and aldicarb presents [M+Na]$^{+}$ and [M-OCONH$CH_3$]$^{+}$ ion which is the most decisive fraction ion for pesticides such as bendiocarb, carbaryl, carbofuran, ethiofencarb, methiocarb, methomyl, propoxur excluding [M+H]$^{+}$ ion. However, [M-OCONH$CH_3$]$^{+}$ and [M-OCONH$CH_3$]$^{+}$ fraction ion charactering carbamate pesticides are detected most efficiently with fragment voltage 50ev. As a result, for rluantitative analysis, [M+Na]$^{+}$ ion is the most decisive ion for detection of aldicarb and [M+H]$^{+}$ ion is the most decisive fraction ion for Pesticides such as bendiocarb, carbaryl, carbofuran, ethiofencarb, methiocarb, methomyl, propoxur. Carbaryl-detected pear by HPLC/FLS are analyzed by L/MS and the result shows that [M+H]$^{+}$ and [M-CONH$CH_3$]$^{+}$ ions charactering carbaryl are detected.ering carbaryl are detected.

A Study on the Carbamate Pesticide Residues in Domestic and Imported Crops in Chonnam Province (전라남도에서 유통중인 국내산 및 수입산 곡류 중의 카바메이트제 농약 잔류 실태 연구)

  • 김영국
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.2
    • /
    • pp.164-170
    • /
    • 2000
  • 10 carbamate pesticides were surveyed in domestic and imported green peas, beans, red beans from March 1999 through December 1999. Samples were collected from Gwangju, Mokpo, Suncheon and Yosoo grain markets. This study was performed by post-column ο-phthalaldehyde and 2-mercaptoethanol prior to HPCL fluorophore detection. Pesticides were found in 14 of 80 samples(17.5%). The kinds of pesticide detected in green peas were methomyl, MTMC, carbaryl, those in sesames were oxamyl, carbofuran, carbaryl, 1-naphthol, MIPC, those in beans were oxamyl, MTMC, carbaryl and those in red beans were MTMC, carbaryl. The range of residues detected in green peas, sesames, beans and red beans were 0.002∼0.025ppm, 0.001∼0.469ppm, 0.005∼0.356ppm and 0.017∼0.125ppm, respectively. The most frequently detected pesticides were MTMC(6 times) and carbaryl(5 times), while aldicarb, PHC and BPMC were no detected in all samples. Detection frequencies of carbamate pesticides in imported crops were higher than those in domestic ones except red beans. Only one result of oxamyl residues determined in imported bean was higher than the proposed maximum residue limits of Codex, which was 0.356ppm.

  • PDF

Detection for Multiresidue of the Organophosphorus and Carbamate Pesticides by Enzyme-Inhibition Method (효소 저해법을 이용한 유기인계 및 Carbamate계 농약의 다성분 잔류 검출)

  • 김정호
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.265-272
    • /
    • 2002
  • This study was carried out with the detection for multiresidue of the organophosphorus pesticides such as malathion, parathion. diazinon, and carbamate pesticide such as carbaryl, by enzyme-inhibition method. The acetylcholinesterase (AChE) and cholinesterase (ChE) activities in chicken brain determined by the Ellman's method were 166.6 and 5.8 $\mu$mol/min/g protein, and in chicken plasma were 23.1 and 8.3 $\mu$mol/min/g protein, respectively. The optimum pH of AChE and ChE was 8.2 and 7.8, respectively. The Km of AChE and ChE was 0.034 and 0.045 mM, respectively. I$\_$50/ for AChE and ChE by some organophosphorus was 55.82 and 99.42 mg/L of malathion, 31.16 and 29.13 mg/L of parathion, and 17.89 and 19.62 mg/L of diazinon, respectively. I$\_$50/ for AChE and ChE by carbaryl of carbamate was 0.10 and 0.05 mg/L, respectively. The 0.07 mg/L of drinking water advisory level for carbaryl could be detected with I$\_$50/ of AChE and ChE. Enzyme-Inhibition (EI) method with AChE and ChE was used the multiresidue method to detect the 1 mg/L of the carbamate pesticides.

Development of an Inverted Y-Shaped Strip for the Detection of Organophosphorus and Carbamate Residual Pesticides (유기인계 및 카바메이트계 농약 신속 검출을 위한 역 Y자 스트립의 개발)

  • Lee, Jeong-Eun;Kim, Sol-A;Park, Hyun-Jin;Mun, Hyoyoung;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The inverted Y-shaped strip detection method based on acetylcholinesterase (AChE) was developed for the rapid detection of organophosphorus and carbamate pesticides. The inactivation of AChE by organophosphorus and carbamate pesticides has been well known. The AChE catalyzes acetylthiocholine into thiocholine having (-) and (+) charges, and the (+) charge results in aggregation of gold nanoparticle (GNP). Malaoxon and carbofuran were used as standard organophosphorus and carbamate for the development of the inverted Y-shaped strip, respectively. In order to optimize the method, various angles of the Y-shaped strip, different types of nitrocellulose membrane, and concentration of AChE were tested as key parameters. The detection limit of the method was 10 ng/mL for both malaoxon and carbofuran pesticides. No cross-reaction was observed to other pesticides such as atrazine, cyanazine, simazine, bifenthrin, boscalid, metalaxyl, and chlorobenzilate. Recoveries from lettuce spiked when known concentrations of malaoxon and carbofuran were found ranging from 96.4 to 100.7% and 81 to 112.7%, respectively. This study suggests that the inverted Y-shaped strip method based on AChE may be a useful tool for the sensitive, specific, rapid detection of organophosphorus and carbamate pesticides in agricultural products.

Studies on the Residues of Carbamate Pesticide in Fruits and Vegetables (과일 및 야채의 Carbamate계 농약의 잔류량)

  • 이해금;최용순;최규열
    • Journal of Food Hygiene and Safety
    • /
    • v.2 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • ABSTRACT-Agricultural products collected from the suburbs of Chuncheon in 1984 were analyzed for carbamate pesticides by GLC-NPD. O-tert-butyl phenyl methyl carbamate(BPMC) was detected in most samples and their residue levels in strawberry, tomato, cucumber, grape, apple and chinese cabbage were in the range of non-detectable to 0.2356 ppm(Av. 0.0539 ppm). 1- naphthyl methyl carbamate(N AC) were detected in cucumber, grape and chinese cabbage and their residue levels were in the range of non-detectable to 0.0265 ppm. O-cumeryl methyl carbamate(MIPC) was detected in only chinese cabbage and its residue levels were in the range of non-detectable to 0.0059 ppm. Detection frequencies of BPMC, MIPC and NAC in the chinese cabbage were higher than those the others.others.

  • PDF

Creating Highly Sensitive and Selective Biochip Sensors for the Detection of Organophosphorus/carbamate Pesticides (고감도 및 고선택성의 유기인계/카바메이트계 농약 검출용 바이오칩 센서)

  • Sim, Hyerim;Kim, Suhee;Lee, Jaeyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.571-580
    • /
    • 2009
  • Biochip sensing technologies offering in-situ, fast and real-time measurements in addition to portability can be powerfully utilized in a wide spectrum of research areas including environmental science, food science, medical diagnostics and drug development. In this article, we introduce current research trends and economic aspects of the development of various optical biochip technologies for the analysis of organophosphorus/carbamate pesticides in environmental samples, which is of global importance with serious consequences for both current and future generations. In particular, we will highlight recent efforts made in the creation of highly sensitive and selective optical biochip sensors in conjunction with nanobiotechnologies and microfabrication for the rapid detection of organophosphorus/carbamate pesticides.