Browse > Article

Detection for Multiresidue of the Organophosphorus and Carbamate Pesticides by Enzyme-Inhibition Method  

김정호 (경산대학교 환경학부)
Publication Information
Environmental Analysis Health and Toxicology / v.17, no.3, 2002 , pp. 265-272 More about this Journal
Abstract
This study was carried out with the detection for multiresidue of the organophosphorus pesticides such as malathion, parathion. diazinon, and carbamate pesticide such as carbaryl, by enzyme-inhibition method. The acetylcholinesterase (AChE) and cholinesterase (ChE) activities in chicken brain determined by the Ellman's method were 166.6 and 5.8 $\mu$mol/min/g protein, and in chicken plasma were 23.1 and 8.3 $\mu$mol/min/g protein, respectively. The optimum pH of AChE and ChE was 8.2 and 7.8, respectively. The Km of AChE and ChE was 0.034 and 0.045 mM, respectively. I$\_$50/ for AChE and ChE by some organophosphorus was 55.82 and 99.42 mg/L of malathion, 31.16 and 29.13 mg/L of parathion, and 17.89 and 19.62 mg/L of diazinon, respectively. I$\_$50/ for AChE and ChE by carbaryl of carbamate was 0.10 and 0.05 mg/L, respectively. The 0.07 mg/L of drinking water advisory level for carbaryl could be detected with I$\_$50/ of AChE and ChE. Enzyme-Inhibition (EI) method with AChE and ChE was used the multiresidue method to detect the 1 mg/L of the carbamate pesticides.
Keywords
Multiresidue method; Enzyme inhibition; Bioindicators; Acetylcholinesterase; Cholinesterase; Organophosphorus pesticides; Carbamate pesticides;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Dzyadevych S.V., and Chovelon J.-M. A comparative photodegradation studies of methyl parathion by using lumistox test and conductometric biosensor technique. Materials and Engineering. 2002; C21 : 55-60   DOI   ScienceOn
2 Ghindilis, A.L., Morzunova, H.C., Barmin, A.V., and Kurochkin, I.N. Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelctrocatalysis. Biosensors and Bioelectronics 1996; 11 : 837-880
3 Matsumura, F., Toxicology of insecticides, Plenum Press, New York. 1975; 105-164
4 Varo I., Navarro J.C., Amat F., and Guilhermino L. Characterisation of cholinesterases and evaluation of the inhibitory potential of chlorpyrifos and dichlorvos to artemia salina and artemia parthenogenetica. Chemosphere 2002 ; 48: 563-569   DOI   ScienceOn
5 유홍일, 이해근, 전성환, 농약잔류 분석방법, 동화기술 1991
6 정영호, 박영선, 농약학, 전국농업기술자협회, 문선사 1990
7 Bachmann, T.T., and Schmid, R.D. A disposable, multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution. Analytica Chimica Acta 1999; 401 : 95-103   DOI   ScienceOn
8 Bergmeyer, H.H. Methods of enzymatic analysis, 3nd ed., Vol. IV, Verlagchemie. 1984; 52-74
9 Dzyadevych S.V., Soldatkin A.P., and Chovelon J.-M. Assessment of the toxicity of methyl parathion and its photodegradation products in water samples using conductometric enzyme biosensors. Analytica Chimica Acta 2002; 459: 33-41   DOI   ScienceOn
10 Eto. M., Organophosphorus pesticides-organic and biological Chemistry, CRC. 1974
11 Ellman, G.L., Courtney K.D., Andres Jr.V., and Featherstone R.M. A new and rapid calorimetric determination of acetycholinesterase activity. Biochem. Pharmacol. 1961; 7: 88-95   DOI   ScienceOn
12 Gulla K.C., Gouda M.D., Thakur M.S., and Karanth N.G. Reactivation of immobilized acetyl cholinesterase in an amperometric biosensor for organophosphorus pesticide. Biochimica et Biophysica Acta 2002; 1597 : 133-139   DOI
13 Reybier K., Zairi S., Jaffrezic-Renault N., and Fahys B. The use of polyethyleneimine for fabrication of potentiometric cholinesterase biosensors. Talanta 2002; 56 : 1015-1020   DOI   ScienceOn
14 Tomlin C., The pesticide manual, 12th ed., British crop protection council, United Kingdom. 2000
15 Saul, J.S., Zomer, E., Puopolo, D., Charm, S.E. Use of a new rapid bioluminescence method for screening organophosphate and N-methylcarbamate insecticides in processed baby food. J. Food Protection 1995; 59 : 303-311
16 Aprea C., Colosio c., Mammone T., Minoia C., and Maronib M. Biological monitoring of pesticide exposure: a review of analytical methods. J. Chromatogr. 2002; B769 : 191-219   DOI   ScienceOn
17 Lowry, O.H., Roesbrough N.J., Favr A.L and R.J., Randall, Protein measurement with the folin phenol reagent, J. Biol. Chem. 1951; 193: 265-275
18 Ivanov A.N., Lukachova L.V., Evtugyn G.A., Karyakina E.E., Kiseleva, S.G. Budnikov H.C., Orlovc A.V, Karpacheva G.P., and Karyakin A.A. Polyaniline-modified cholinesterase sensor for pesticide determination. Bioelectrochem. 2002; 55: 75-77   DOI   ScienceOn
19 Stryer L. Biochemistry. 2nd ed. Freeman & Com. USA. 1981; 103-134
20 Albareda-Sirvent M., Merkoci A., and Alegret S. Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology. Analytica Chimica Acta 2001; 442:35-44   DOI   ScienceOn
21 Evtugyn, G.A., Budnikov, H.C., and Nikolskaya, E.B. Influence of surface-active compounds on the response and sensitivity of cholinesterase biosensors for inhibitor determination. Analyst 1996; 121 : 1911-1915   DOI   ScienceOn
22 Bachmann, T.T., Leca, B., Villatte, F., Marty, J.-L., Fournier, D., and Schmid, R.D. Improved multianalyte detection of organophosphates and carbamates with disposable multiresidue biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks. Biosensors and Bioelectronics 2000; 15 : 193-201   DOI   ScienceOn
23 Collier W.A., Clear M., and Hart A.L. Convenient and rapid detection of pesticides in extracts of sheep wool. Biosensors and Bioelectronics 2002; 17: 815-819   DOI   ScienceOn
24 Kuhr, R.J., Carbamate insecticides; chemistry, biochemistry, and toxicology, CRC, Ohio. 1977
25 Abad, J.M., Pariente, F., Hernandez, L., Abruna, H.D., and Lorenzo, E. Determination of organophosphorus and carbamate pesticides using piezoelectric biosensors. Analytical Chemistry 1998; 70 : 2848-2855   DOI   ScienceOn
26 Mionetto, N., Marty, J.L., and Karubc, I. Acetylcholinesterase in organic solvents for the detection of pesticides: biosensor application. Biosensors and Bioelectronics 1994; 9 : 463-470   DOI   ScienceOn
27 환경부, http://nkkfem.or.kr/sub3/먹는물기준.htm. 2002